DOWNLOAD Sharp MX-5500N / MX-6200N / MX-7000N (serv.man120) Service Manual ↓ Size: 43.47 KB | Pages: 5 in PDF or view online for FREE

Model
MX-5500N MX-6200N MX-7000N (serv.man120)
Pages
5 Few pages! See other manuals at the bottom of the first or last page.
Size
43.47 KB
Type
PDF
Document
Service Manual / Technical Bulletin
Brand
Device
Copying Equipment / CCE-744 MX-FRX3U DSK FIRMWARE ROM UPGRADE ICU VERSION 01.15.Dm Production Run Date December 2009
File
mx-5500n-mx-6200n-mx-7000n-sm120.pdf
Date

Sharp MX-5500N / MX-6200N / MX-7000N (serv.man120) Service Manual / Technical Bulletin ▷ View online

 
 
 
Sharp Electronics (UK) Ltd., Document Systems Support
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
ROM UPGRADE ..... (4).
 
 
 
1.Model Name: 
MX-FRX3U (DSK options for MX-5500N/6200N/7000N) 
 
2.Description: 
Upgrade of ICU-ROM 
 
 
From December 2009 production 
ROM control No. 
ICU 
C00 
0115Dm 
Note: Before upgrading the ROM, check "Default Paper Size" by selecting 
[SYSTEM SETTINGS] 
 [Printer Condition Setting] 
 [Printer Default Setting] 
from  the  operation  panel.  After  upgrading  the  ROM,  set  the  checked  paper  size 
again. 
Item of change: See the accompanying sheet. 
 
ROM Version Combination History Table 
No. 
ROM administration 
ICU 
Action 
Issued T/R No. 
(3) 
B01 
0112Dm 
2007/11 
CCE-527R 
(2) 
B00 
0103Dm 
2007/7 
CCE-484 
(1) 
A02 
0101Dm 
2007/2 
Mid 
CCE-445 
TECHNICAL BULLETIN 
Date: 4
th
 March 2010 
 
Model: MX-FRX3U  
(DSK option for MX-5500N/6200N/7000N) 
Ref.:   
CCE744 
Colour:  
White 
Page:  
1 of 5 
 
 
 
Sharp Electronics (UK) Ltd., Document Systems Support
 
 
 
[Description] 
No. 
Subject 
Description 
Support for new 
standards of the 
International Energy 
Star program 
The criteria change of the International Energy Star program involves the following 
changes of the factory default values for the function of preheating and auto power 
shutoff: 
Model 
name 
Destinatio
Before change 
After change 
Preheatin
Auto 
power 
shutoff 
Preheatin
Auto 
power 
shutoff 
MX-5500N 
Europe 
Australia 
China 
15 min. 
90 min. 
1 min. 
30 min. 
MX-6200N J 
North 
America 
15 min. 
90 min. 
1 min. 
30 min. 
MX-6200N 
China 
15 min. 
90 min. 
1 min. 
30 min. 
Notes: 
Updating to this version dose not involve any change of the setting value for the 
MFP printer. 
The time required for the function of preheating and auto power shutoff to be 
active will be reset to the factory default value as described above; 
- when a system administrator performs the operation of saving and/ 
- or calling system settings and then resets to the factory default value, or when 
destination change (Sim26-6) is implemented. 
Main body control-
related 
The specifications have been changed so that continuous jobs can be accepted 
using "no temporary accounting mode" and the "no temporary accounting + filing" 
function. 
Main body control-
related 
If the Equitrac card reader cannot read information or if the CPU is heavily loaded, 
a key may not be read. This glitch has been corrected. 
Main body control-
related 
By combining the optional data security kit and the HDD on the MFP main device, 
PPD2-PRI JAM would be displayed at the first copy job after the device had been 
turned on. This glitch has been corrected. 
Main body control-
related 
When acquired or updated, the delivery tray state may rarely change to top tray 
output to the offset tray. This glitch has been corrected. 
Printer-related 
The PCL macro cannot be registered in the HDD. This glitch has been corrected. 
Printer-related 
If text data is printed from AS400 via Adobe Output Design V5.6 in PCL5c, only one 
page may be printed. This glitch has been corrected. 
Printer-related 
When printing from a Mac, printing via AppleTalk may take a longer time than 
printing via LPR. This glitch has been corrected. 
Printer-related 
If a specific device cloning file is imported to another MFP, there may be cases 
where "Now Analyzing" remains displayed and the MFP randomly hangs up. This 
glitch has been corrected. 
10 
Printer-related 
If an exception handling the glitch occurs during decimal operation in PS mode, 
there may be cases where "Now Analyzing" remains displayed and an attempt to 
print specific data with PowerPoint or Adobe InDesign 2.0 fails. This glitch has 
been corrected. 
11 
Printer-related 
Illustrator 10 may take an extremely long time to print data including a gradated 
color. This glitch has been corrected. 
12 
Printer-related 
If a color image is printed in black and white in PS mode, red and yellow parts (of 
the colors specified in DeviceCMYK, those where k is "0") may not be printed 
correctly. This glitch has been corrected. 
 
 
 
Sharp Electronics (UK) Ltd., Document Systems Support
 
 
 
 
No. 
Subject 
Description 
13 
Printer-related 
If an attempt is made to print several pieces of specific data from Mac FileMaker, 
there may be cases where "Now Analyzing" remains displayed and printing fails. 
This glitch has been corrected. 
14 
Printer-related 
Printing from Adobe InDesign or Morisawa sheet maker in PS mode may take a 
long analysis time. This glitch has been corrected. 
15 
Printer-related 
If A4/A3 mixed pages created by Microsoft Office/Word 2003 are printed in 2up 
double face printing, the image pasted to the back surface of A3 paper may be lost. 
This glitch has been corrected. 
16 
Printer-related 
If CMYK simulation is selected and a specific PDF file is printed, a PS error may 
occur. This glitch has been corrected. 
17 
Printer-related 
The PS form registered in the HDD may not be printed correctly. This glitch has 
been corrected. 
18 
Printer-related 
If both sides of an odd page document are printed when MX-PEX3 (Fiery controller) 
is used, the count may be made by one page extra. This glitch has been corrected. 
19 
Printer-related 
If excel data, including specific AutoShape data, is printed with the printing quality 
on the application side set to "300dpi", the AutoShape image may not be printed 
correctly. This glitch has been corrected. 
20 
Printer-related 
If data including the <ESC>E command is printed, there may be cases where the 
<ESC>E command is judged as the end of the job and original single job is 
handled as several jobs. This glitch has been corrected. 
21 
Printer-related 
Illustrator Ver. 9 and earlier may print void in color. This glitch has been corrected. 
22 
Printer-related 
Printing the PDF file scanned in a monochrome binary with Acrobat 8.0 may take 
time because image data is internally processed into color data for black/white 
printing and then printed in color. This glitch has been corrected. 
23 
Printer-related 
Data including color graphics may not be printed correctly by AS400. This glitch 
has been corrected. 
24 
Printer-related 
The printing speed of the document created by PowerPoint 2007 may become 
extremely slow if the document includes a specific TrueType font. This glitch has 
been corrected. 
25 
Printer-related 
Printing is now supported for specific applications for specific files that include 
improper characters in files names, such as line returns. 
26 
Printer-related 
In PCL5e, a line command per inch "&l8D" may not function. This glitch has been 
corrected. 
27 
Printer-related 
Printing of a specific PDF file by Adobe Acrobat may cause a PS error or take an 
extremely long time. This glitch has been corrected. 
28 
Printer-related 
The USTATUS message used to report RESULT=OK may not be sent in reply to the 
font page print request from the server and at this time, the server that resends the 
font page print request may repeatedly print the same font page every 90 seconds. 
This glitch has been corrected. 
29 
Printer-related 
The specified PCL macro paper size is incorrect, so when all pages are printed, 
there may be cases where only the first page is printed in legal size and the second 
and subsequent pages are printed in letter size. This glitch has been corrected. 
30 
Printer-related 
When a specific file is printed by PowerPoint2004 under the Mac OS 10.4.7 
environment, a part of a ruled line in the object may not be printed. This glitch has 
been corrected. 
 
 
 
Sharp Electronics (UK) Ltd., Document Systems Support
 
 
 
 
No. 
Subject 
Description 
31 
Printer-related 
If A3 both-side printing is performed for a printed matter whose number of pages is 
greater than Quark Express in the 2in1 format using the spread, there may be 
cases where "Now Analyzing" appears on the MFP main body and the printer is 
unable to print data. This glitch has been corrected. 
32 
Printer-related 
If invalid data is added after the EOI marker of JPEG data in printing of a file such 
as a PowerPoint file including JEPG data, printing cannot be performed because a 
PCL-XL error occurs. A change has been made so that data after the EOI marker is 
ignored and printing is performed. 
33 
Network related 
SSL communication (HTTPS, FTPS, SMTP-SSL, POP3-SSL, LDAP-SSL) for the 
client port (MFP 
 client PC) has been supported. 
34 
Document filing 
related 
A communication error may occur if FTP pull print is performed for the FTP server 
on the Novell NetWare 5.x server. This glitch has been corrected. 
35 
Software switch-
related 
If OSA external summing mode is enabled, a change is made so that soft SW154-2 
does not function at all times. This time, however, if OSA external summing mode 
is not enabled, a change has been made so that soft SW154-2 functions. 
36 
Image transmission 
related 
If "Scan to Network folder" is performed from SMB in the Kerberos system using a 
long user principal name, a "CE-00" error may occur. This glitch has been 
corrected. 
37 
Image transmission 
related 
If the scanned data is transmitted to non-Windows OS through "Scan to shared 
folder" of the MFP main body, the SMB server based on non-Windows OS may 
respond differently from the SMB standard communication procedure, causing the 
SMB client error. This glitch has been corrected so that the scanned data can be 
transmitted correctly by ignoring such response on the MFP main body side. 
38 
Webpage related 
If an attempt is made to save the data registered via scan to the PC from the WEB 
page or to delete it from the PC, "ERROR3000" may occur to disable operation. 
This glitch has been corrected. 
39 
OSA related 
If a template with an external image is drawn with the LAN disconnected when OSA 
is used, the main body may hang up. This glitch has been corrected. 
40 
OSA related 
OSA may not operate normally if a specific image sent via Internet (WAN) exists in 
the full VGA panel MFP. This glitch has been corrected. 
41 
OSA related 
If an external image exists on the next page to which OSA transited during external 
image acquisition, the external image being acquired on the previous page may be 
drawn as the external image on the next page to which OSA transited. This glitch 
has been corrected. 
42 
OSA related 
If an image is redrawn in the input template when OSA is used after OK or CANCEL 
on the soft keyboard is clicked, the soft keyboard may be displayed again. This 
glitch has been corrected. 
43 
OSA related 
If images such as the vendor logo exist in the OSA template screen, the incorrect 
sequence may occur between the acquisition processing of this external image 
and the drawing processing of the next screen (soft keyboard), resulting in MFP 
freeze in logging in after return from power saving mode. This glitch has been 
corrected. 
44 
OSA related 
If keys are pressed quickly and continuously when the external application is valid, 
"The data from external application is in incorrect format. Call for service" 
message may be displayed. This glitch has been corrected. 
45 
MIB information 
related 
Of counter information displayed in the MFP main body, items that do not exist in 
MIB information have been added to MIB information. 
Page of 5
Display

Sharp MX-5500N / MX-6200N / MX-7000N (serv.man120) Service Manual / Technical Bulletin ▷ Download

  • DOWNLOAD Sharp MX-5500N / MX-6200N / MX-7000N (serv.man120) Service Manual ↓ Size: 43.47 KB | Pages: 5 in PDF or view online for FREE
  • Here you can View online or download the Service Manual / Technical Bulletin for the Sharp MX-5500N / MX-6200N / MX-7000N (serv.man120) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp MX-5500N / MX-6200N / MX-7000N (serv.man120) Copying Equipment. Information contained in Sharp MX-5500N / MX-6200N / MX-7000N (serv.man120) Service Manual / Technical Bulletin (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.