Sharp AR-C170 (serv.man26) Service Manual ▷ View online

AR-C170M  SIMULATION  9 - 1
[9] SIMULATION
(Diagnostics, setup, adjustment value 
input, data display)
1. Outline and purpose
The simulation has the following functions to grasp the machine 
operating status, identify the trouble position and causes in an 
earlier stage, and make various setups and adjustments speedily 
for improving the serviceability of the machine.
1) Various adjustments
2) Setup of specifications and functions
3) Canceling troubles
4) Operation check
5) Various counters check, setup, and clear
6) Machine operating status (operation history) data check, clear
7) Transfer of various data (adjustments, setup, operations, 
counters)
The operating procedures and the displays differ depending on the 
form of the operation panel of the machine.
2. Code-type simulation
A. Operating procedures and operations
Entering the simulation mode
1) #/P key (program) ON 
 Asterisk (*) key ON 
 CLEAR (C) 
key ON 
 Asterisk (*) key ON 
 Ready for input of a main 
code of simulation
2) Entering a main code with the 10-key 
 START (Black copy) 
key ON
3) Entering a sub code with the 10-key 
 START (Black copy)  
key ON
4) Select an item with the scroll key and the item key.
5) The machine enters the mode corresponding to the selected 
item.
Press START key or EXECUTE key to start the simulation 
operation.
To cancel the current simulation mode or to change the main 
code and the sub code, press the user setup key.
Canceling the simulation mode to return to the normal mode
1) Press CLEAR ALL (CA) key.
AR-C170M  SIMULATION  9 - 2
YES
NO
NO
YES
YES
YES
NO
NO
NO
YES
NO
YES
YES
NO
NO
YES
YES
NO
Standby for entry of SIM
sub code
Enter SIM sub code with
the 10-key.
Press the START button.
The display is made according
to the selected mode and the item.
START (Normal mode)
Press the #/P key.
Press the asterisk (*) key.
Press the clear (C) key.
Press the asterisk (*) key.
Standby for entry of
SIM code.
Enter the main code of
SIM with the 10-key.
The main code of SIM
is displayed.
Press the START button.
Is there a sub code ?
Select the mode and the
item with the scroll key 
and the item key.
he
Operation check ?
Operating conditions
check ?
Data clear ?
Adjustments
or setting (counter data
change) ?
Do you
want to change the
content ?
Enter the new setting and
adjustment values.
Press the CUSTOM 
SETTINGS key
Press the CUSTOM 
SETTINGS key
Press the EXECUTE button
and OK button.
Operation is made according
to the selected mode and item.
Press the EXECUTE button
and OK button.
Press the EXECUTE button
and OK button.
The display is made according to
the selected some and the item.
Press the EXECUTE button
and OK button.
Is it the same
simulation ?
Do you want
to perform another
simulation ?
Do you
want to end the
simulation ?
The changed content
is stored.
The simulation mode
is canceled.
Press the clear all (CA) key.
Operation is made according
to the selected mode and the item.
(Other modes)
The selected mode and
the item are cleared.
AR-C170M  SIMULATION  9 - 3
B. Simulation list
(1) Main/ Sub
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
1
1
Used to check the operations of the 
scanner unit and its control circuit.
Operation test/check
Scanner (reading)
Operation
2
Used to check the sensors and 
detectors in the scanner section and 
the related circuits.
Operation test/check
Scanner (reading)
Operation
5
Used to check the scanner 
(scanning) unit and its control circuit.
Operation test/check
Scanner (reading)
Operation
2
2
Used to check the operations of the 
sensors and detectors in the 
document feeder unit and their 
related circuits. 
Operation test/check
Automatic document 
feeder
Operation
3
Used to check the operations of the 
motors, solenoids, and the PS clutch 
in the document feeder unit. 
Operation test/check
Automatic document 
feeder
Operation
3
2
Used to check the operations of the 
sensors and detectors in the finisher 
and the related circuits.
Operation test/check
Finisher
Operation
3
Used to check the loads in the 
finisher and the control circuit.
Operation test/check
Finisher
Operation
10
Used to adjust the sections in the 
finisher.
Operation test/check
Finisher
Operation
4
2
Used to check the operations of the 
desk/large capacity tray sensors and 
detectors and the related circuits.
Operation test/check
Paper feed
Operation
3
Used to check the operations of the 
desk/large capacity tray loads and 
the control circuit.
Operation test/check
Paper feed
Operation
5
Used to check the operations of the 
clutch TRC and the monitor.
Operation test/check
Paper feed
Operation
5
1
Used to check the operations of the 
display lamp (LED)/LCD on the 
operation panel and the control 
circuits. 
Operation test/check
Operation (Display, 
procedure)
Operation
2
Used to check the operations of the 
heater lamp and its control circuit.
Operation test/check
Fusing
Operation
3
Used to check the operations of the 
scanner lamp and its control circuit.
Operation test/check
Scanner (reading)
Operation
4
Used to check the operations of the 
discharge lamp and its control 
circuit. 
Operation test/check
Process 
(Photoconductor, 
developing, transfer, 
cleaning)
Others
Operation
6
1
Used to check the operations of the 
loads (clutches and solenoids) in the 
paper transport system, transfer, 
and fusing, and the control circuit.
Operation test/check
Paper transport (paper 
exit, switchback, 
transport), transfer, 
fusing
Operation
2
Used to check the operations of the 
fan motors and the control circuits.
Operation test/check
Others
Operation
7
1
Used to set the aging conditions.
Setting/Operation test/
check
Operation
6
Used to set the cycle of intermittent 
aging.
Setting/Operation test/
check
Operation
8
Used to set Yes/No of warm-up time 
display.
Setting/Operation test/
check
Operation
9
Used to check the image quality and 
operations of each color.
Operation test/check
Others
Picture quality
8
1
Used to check and adjust the 
operations of the developing bias 
voltage of each color and the control 
circuit.
Adjustment/Operation 
test/check
Process 
(Photoconductor, 
developing, transfer, 
cleaning)
2
Used to check and adjust the 
operation of each print mode main 
charger grid voltage and the control 
circuit.
Adjustment/Operation 
test/check
Process 
(Photoconductor, 
developing, transfer, 
cleaning)
6
Used to check and adjust the 
operation of the transfer charger 
current and the control circuit.
Adjustment/Operation 
test/check
Process 
(Photoconductor, 
developing, transfer, 
cleaning)
Transfer
9
2
Used to check the operation of the 
sensors and detectors in the 
inverter/duplex section and the 
control circuit.
Operation test/check
Inverter/Duplex
Operation
AR-C170M  SIMULATION  9 - 4
9
3
Used to check the operations of the 
loads (motor, clutch, solenoid) in the 
inverter/duplex section and the 
control circuits.
Operation test/check
Inverter/Duplex
Operation
14
0
Used to cancel self diag troubles H3, 
H4, and H5. Inhibition of the color 
copy mode operation is canceled.
Clear/cancel (Trouble 
etc.)
Trouble
Error
15
0
Self diag U6-09 (large capacity 
paper feed tray) trouble cancel
Clear/cancel (Trouble 
etc.)
Paper feed
Trouble
16
0
Used to cancel self diag trouble U2.
Clear/cancel (Trouble 
etc.)
Trouble
Error
17
0
Used to cancel self diag troubles PF 
(copy inhibition command from the 
host computer).
Clear/cancel (Trouble 
etc.)
Communication (RIC/
MODEM)
Trouble
Error
21
1
Used to set the maintenance cycle.
Setting
Specifications
Counter
22
1
Used to check the print count value 
in each section and each operation 
mode. (Used to check the 
maintenance timing.)
Adjustment/Setting/
Operation data output, 
check (display, print)
Counter
2
Used to check the total misfeed 
count and the total trouble count. (If 
the misfeed count is considerably 
great, it may be judged as necessary 
to repair. By dividing this count by 
the total count, the misfeed rate can 
be obtained.)
Adjustment/Setting/
Operation data output, 
check (display, print)
Trouble
3
Used to check misfeed positions and 
the misfeed count of each position. 
(If the misfeed count is considerably 
great, it may be judged as necessary 
to repair.) (Machine section only)
Adjustment/Setting/
Operation data output, 
check (display, print)
Trouble
Misfeed
4
Used to check the total trouble (self 
diag) history.
Adjustment/Setting/
Operation data output, 
check (display, print)
Trouble
5
Used to check the ROM version of 
each unit (section).
Others
Software
6
Used to print the setting and 
adjustment data list.
Adjustment/Setting/
Operation data output, 
check (display, print)
Data
Setting/
Adjustment data
7
Used to display the key operator 
code. (Used when the customer 
forgets the key operator code.)
User data output/
Check (Display/Print)
Data
User data
8
Used to check the number of scan 
(read) of the staple and the 
document feed unit.
Adjustment/Setting/
Operation data output, 
check (display, print)
Counter
9
Used to check the number of uses 
(print quantity) of each paper feed 
section.
Adjustment/Setting/
Operation data output, 
check (display, print)
Paper feed
Counter
10
Used to check the system 
configuration (option, internal 
hardware).
Adjustment/Setting/
Operation data output, 
check (display, print)
Specifications
Option
11
Used to check the number of use of 
FAX. (When the FAX is installed)
Adjustment/Setting/
Operation data output, 
check (display, print)
FAX
Counter
12
Used to check the misfeed positions 
and the number (history) of misfeed 
at each position. (If the misfeed 
count is considerably great, it may 
be judged as necessary to repair.)
Adjustment/Setting/
Operation data output, 
check (display, print)
Automatic document 
feeder
Trouble
Misfeed
13
Used to check the process cartridge 
counter. (If the count number is 
considerably great, it may be judged 
as necessary for repair.)
Adjustment/Setting/
Operation data output, 
check (display, print)
Process section
Counter
19
Used to check the counters related 
to the network scanner.
Adjustment/Setting/
Operation data output, 
check (display, print)
Network scanner
Counter
24
1
Used to clear the misfeed counter, 
the misfeed history, the trouble 
counter, and the trouble history. 
(After completion of maintenance, 
the counters are cleared.)
Data clear
Memory
Counter
2
Used to clear the data of the number 
of uses (print quantity) of each paper 
feed section.
Data clear
Paper feed
Counter
Paper feed unit
3
Used to clear the number of scan 
(read) of the staple and the 
document feed unit. 
Data clear
Transport/Finisher
Counter
Code
Function (Purpose)
Purpose
Section
Item
Main
Sub
Page of 72
Display

Sharp AR-C170 (serv.man26) Service Manual ▷ Download

  • DOWNLOAD Sharp AR-C170 (serv.man26) Service Manual ↓ Size: 3.39 MB | Pages: 72 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp AR-C170 (serv.man26) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp AR-C170 (serv.man26) Copying Equipment. Information contained in Sharp AR-C170 (serv.man26) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.