AR-C170M  SIMULATION  9 - 17
2. When the [EXECUTE] key is pressed, the key is highlighted 
and the selected discharge lamp is lighted for 30sec. If the 
[EXECUTE] key is pressed while the lamp is lighted, the lamp 
is turned OFF.
(Loads to be selected)
When BLUM is ON, the belt moves up.
When BLUM is OFF, the belt moves down.
2. Press the [EXECUTE] key.
The selected load is operated. During operation, the 
[EXECUTE] key is highlighted. If the [EXECUTE] key is 
pressed while it is highlighted, the operation is stopped.
(Loads to be selected.)
The setup contents of this simulation remain unchanged until 
the power is turned off. When this simulation is executed, SIM 7-
8 (Warm-up time display setting) is canceled.
(Set content)
5
-4
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operations of the discharge lamp 
and its control circuit.
/
Section
Process (Photoconductor, developing, 
transfer, cleaning)
Others
Item
Operation
Operation/
Procedure
1. Select the target discharge lamp with the [K], [C], 
[M], and [Y] keys. (K: Black, C: Cyan, 
M: Magenta, Y: Yellow)
6
6
-1
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operations of the loads (clutches 
and solenoids) in the paper transport system, 
transfer, and fusing, and the control circuit.
Section
Paper transport (paper exit, switchback, transport), 
transfer, fusing
Item
Operation
Operation/
Procedure
1. The names of the loads that can be checked are 
displayed. Select the load to be checked with the 
key, and the selected load is highlighted.
2. Press the [EXECUTE] key. The selected load 
starts the operation. During the operation of the 
load, the [EXECUTE] key is highlighted. If the 
[EXECUTE] key is pressed while it is highlighted, 
the operation is stopped.
CPFC
Cassette transport clutch
TRC
Cassette paper feed clutch
MTRC
Manual paper feed clutch
MPFC
Manual transport clutch
GSS
Paper exit gate select solenoid
RRM
Resist roller motor (PSM)
PFM
Paper feed motor (Vertical transport)
FUM
Fusing motor
BLUM
Lift motor
BLUM (R)
Lift motor (Reverse rotation/waste toner transport 
motor)
OSM
Offset motor (Job separator)
CARB
Calibration plate
6
-2
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operations of the fan motors and 
the control circuits.
Section
Others
Item
Operation
Operation/
Procedure
1. The loads that can be checked are displayed. 
Select one to be checked.
VFM1
Fusing fan 1
VFM2
Fusing fan 2
PSFM
Power fan
PRTCFM
Process exhaust fan
SIROCCOFM
Sirocco fan
7
7
-1
Purpose
Setting/Operation test/check
Function 
(Purpose)
Used to set the aging conditions.
Item
Operation
Operation/
Procedure
1. Press each corresponding key to set for the 
aging operation.
(Set items of each key)
The selected key is highlighted.
2. Press the [EXECUTE] key.
Aging is set and the display returns to the 
simulation main code entry menu.
[AGING]
Jam detection setup
[INTERVAL]
Intermittent setup
[MISFEED DISABLE]
Jam detection YES/NO setup
[FUSING DISABLE]
Fusing operation YES/NO detection 
[WARMUP DISABLE]
Warm-up saving setup
[DV CHECK DISABLE] Developing tank detection YES/NO setup
[SHADING DISABLE]
Shading saving setup
[CCD GAIN FREE]
No setting of CCD gain adjustment
AR-C170M  SIMULATION  9 - 18
The interval time set range is 1 - 999 sec. [Default: 3]
The setup contents of this simulation remain unchanged until 
the power is turned off. When SIM 7-1 is executed, the setup 
contents are canceled.
Copying is performed with the color selected in procedure 1).
When no print color is selected, the operation is made with the all 
colors.
The [EXECUTE] key is highlighted. When the adjustment value 
entered in procedure 2) and the corresponding voltage is 
outputted.
The voltage is outputted for 30sec, then the [EXECUTE] key 
returns to the normal display. When the EXECUTE key is pressed 
during output of the voltage, the output is stopped and the 
[EXECUTE] key returns to the normal display.
(Set value)
7
-6
Purpose
Setting/Operation test/check
Function 
(Purpose)
Used to set the cycle of intermittent aging.
Item
Operation
Operation/
Procedure
1. Enter the interval aging cycle time (sec) with the 
10-key pad.
2. Press [OK] key (or B/W Start key, Color Start 
key) to set the entered cycle time.
7
-8
Purpose
Setting/Operation test/check
Function 
(Purpose)
Used to set Yes/No of warm-up time display.
Item
Operation
Operation/
Procedure
Press the [EXECUTE] key to set the warm-up time 
display.
When the [EXECUTE] key is pressed, the warm-up 
time display setting is executed and the display 
returns to the simulation main code entry display.
7
-9
Purpose
Setting/Operation test/check
Function 
(Purpose)
Used to check the image quality and operations of 
each color.
Section
Others
Item
Picture quality
Operation/
Procedure
1. Select the color of image quantity and operation 
check with the key.
2. Press the START key.
8
8
-1
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operations of the 
developing bias voltage of each color and the 
control circuit.
Section
Process 
(Photoconductor, developing, transfer, cleaning)
Operation/
Procedure
(
The developing bias output voltage in each of the 
following print modes can be adjusted and checked.)
(Adjustment range)
0 – 585 (Default: See below)
1. Select the color mode with the [K], [C], [M], or [Y] 
key.
2. Select the copy mode with the scroll key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
Color
Item
Operation mode
Adjustment value
Developing bias voltage
Monitor (High voltage PWB)
Pin 
No.
Actual 
voltage
Adjustment 
range
Specified value 
(Default)
Monitor voltage 
(Specified value)
Connector
K
A: HIGH SPEED
High speed (117mm/s) (B & W)
0 – 585
215
3.94 ± 0.1V
CNMONK
3
–215v
B: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
0 – 585
215
3.94 ± 0.1V
CNMONK
3
–215v
C: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
0 – 585
215
3.94 ± 0.1V
CNMONK
3
–215v
C
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
0 – 585
265
5.76 ± 0.1V
CNMON
1
–265v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
0 – 585
265
5.76 ± 0.1V
CNMON
1
–265v
M
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
0 – 585
265
5.76 ± 0.1V
CNMON
5
–265v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
0 – 585
265
5.76 ± 0.1V
CNMON
5
–265v
Y
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
0 – 585
240
4.75 ± 0.1V
CNMON
9
–240v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
0 – 585
240
4.75 ± 0.1V
CNMON
9
–240v
AR-C170M  SIMULATION  9 - 19
2. Select the print mode with [
] key and [
] key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
The [EXECUTE] key is highlighted, the adjustment value entered 
in procedure 2 is set, and the voltage corresponding to the set 
value is outputted.
The voltage is supplied for 30 sec, then the [EXECUTE] key 
returns to the normal display.
If the [EXECUTE] key is pressed while the voltage is supplied, the 
voltage output is stopped and the [EXECUTE] key returns to the 
normal display.
(Set value)
The [EXECUTE] key is highlighted, the adjustment value entered 
in procedure 2 is set, and the voltage corresponding to the set 
value is outputted.
The voltage is supplied for 30 sec, then the [EXECUTE] key 
returns to the normal display.
If the [EXECUTE] key is pressed while the voltage is supplied, the 
voltage output is stopped and the [EXECUTE] key returns to the 
normal display.
In this simulation, when the transfer voltage is supplied, the 
transfer belt and the OPC drum rotates at the same time. 
Therefore, the above parts are not damaged.
8
-2
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of each print 
mode main charger grid voltage and the control 
circuit.
Section
Process 
(Photoconductor, developing, transfer, cleaning)
Operation/
Procedure
(The charging/grid output voltage in each print mode 
can be adjusted and checked.)
1. Select the color mode with the [K], [C], [M], and 
[Y] keys.
When [EXECUTE] key is pressed, the display is 
highlighted and the currently set voltage is 
outputted.
Color
Item Operation 
mode
Adjustment value
Main charger grid voltage
Monitor (High voltage PWB)
Pin 
No.
Actual 
voltage
Adjustment 
range
Specified 
value (Default)
Monitor voltage 
(Specified value)
Connector
K
A: HIGH SPEED
High speed (117mm/s) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
B: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
C: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
C
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
3
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
180 – 700
620
53.5 ± 0.2v
CNMON
3
–620v
M
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
7
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
180 – 700
620
53.5 ± 0.2v
CNMON
7
–620v
Y
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
11
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W) 
(Special paper)
180 – 700
620
53.5 ± 0.2v
CNMON
11
–620v
8
-6
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of the 
transfer charger current and the control circuit.
Section
Process (Photoconductor, developing, 
transfer, cleaning)
Transfer
Operation/
Procedure
1. Select the color mode with the [K], [C], [M], and 
[Y] keys.
2. Select the copy mode with the scroll key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
AR-C170M  SIMULATION  9 - 20
(Items to be selected/replaced)
(Check item)
While the load operates, the [EXECUTE] key is highlighted.
When the [EXECUTE] key is pressed under this state, the 
operation of the load can be interrupted.
Item
Print mode
Standard setting value 
(Default)
Adjustment 
range
Output voltage (Kv)
K
C
M
Y
K
C
M
Y
A
PLAIN SPX CL
Color
Normal paper
78mm/s
153
141
119
119
51 - 255
2
2
2
2
B
PLAIN DPX CL
Color
Normal paper(Duplex mode)
78mm/s
168
155
129
129
2.3
2.3
2.3
2.3
C
OHP1 CL
Color
Transparency film 1
78mm/s
204
187
153
153
3
3
3
3
D
OHP2 CL
Color
Transparency film 2
58.5mm/s
137
150
153
163
1.7
2.2
3
3.3
E
HEAVY P1 SPX CL
Color
Thick paper 1
58.5mm/s
158
146
122
122
2.1
2.1
2.1
2.1
F
HEAVY P1 DPX CL
Color
Thick paper 1(Duplex mode)
58.5mm/s
188
173
142
142
2.7
2.7
2.7
2.7
G
HEAVY P2 CL
Color
Thick paper 2
58.5mm/s
173
159
132
132
2.4
2.4
2.4
2.4
H
ENVELOPE CL
Color
Envelope
78mm/s
153
141
119
119
2
2
2
2
I
PLAIN SPX BW
B & W
Normal paper
117mm/s
168
2.3
J
PLAIN DPX BW
B & W
Normal paper(Duplex mode)
117mm/s
178
2.5
K
OHP1 BW
B & W
Transparency film 1
78mm/s
204
3
L
OHP2 BW
B & W
Transparency film 2
58.5mm/s
137
1.7
M
HEAVY P1 SPX BW
B & W
Thick paper 1
58.5mm/s
147
1.9
N
HEAVY P1 DPX BW
B & W
Thick paper 1(Duplex mode)
58.5mm/s
178
2.5
O
HEAVY P2 BW
B & W
Thick paper 2
58.5mm/s
163
2.2
P
ENVELOPE BW
B & W
Envelope
117mm/s
168
2.3
9
9
-2
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operation of the sensors and 
detectors in the inverter/duplex section and the 
control circuit.
Section
Inverter/Duplex
Item
Operation
Operation/
Procedure
The operations of sensors and detectors in the 
inverter/duplex section are displayed.
The active sensors and detectors are highlighted.
BPPD1
Inverter transport detection 1
BPPD2
Inverter transport detection 2
BPRD
Inverter reverse detection
BPOD
Inverter paper exit detection
BPFD
Inverter full detection
BDD1
Inverter door detection 1
BDD2
Inverter door detection 2
APPD1
ADU transport detection 1
APPD2
ADU transport detection 2
APHPS
ADU alignment plate home position
POD1
Machine paper exit detection
BYSET
Inverter installation detection
ADUDSET
ADU installation detection
ADUSET
ADU door open/close detection
9
-3
Purpose
Operation test/check
Function 
(Purpose)
Used to check the operations of the loads (motor, 
clutch, solenoid) in the inverter/duplex section and 
the control circuits.
Section
Inverter/Duplex
Item
Operation
Operation/
Procedure
1. Select the load to be checked with the 10-key 
pad. 
2. Press the [EXECUTE] key.
The load selected in procedure 1 operates.
BIM
Inverter paper entry motor
BRMFW
Inverter reverse motor (Normal rotation)
BRMRV
Inverter reverse motor (Reverse rotation)
BGSOL
Inverter gate solenoid
BTMFW
Inverter transport motor (Normal rotation)
BTMRV
Inverter transport motor (Reverse rotation)
ATM
ADU transport motor
APAM
ADU alignment motor
ATRC
ADU transport clutch
Page of 72
Display

Click on the first or last page to see other AR-C170 (serv.man26) service manuals if exist.