Sharp AR-C170 (serv.man26) Service Manual ▷ View online
AR-C170M SIMULATION 9 - 17
2. When the [EXECUTE] key is pressed, the key is highlighted
and the selected discharge lamp is lighted for 30sec. If the
[EXECUTE] key is pressed while the lamp is lighted, the lamp
is turned OFF.
[EXECUTE] key is pressed while the lamp is lighted, the lamp
is turned OFF.
(Loads to be selected)
∗
When BLUM is ON, the belt moves up.
When BLUM is OFF, the belt moves down.
When BLUM is OFF, the belt moves down.
2. Press the [EXECUTE] key.
The selected load is operated. During operation, the
[EXECUTE] key is highlighted. If the [EXECUTE] key is
pressed while it is highlighted, the operation is stopped.
[EXECUTE] key is highlighted. If the [EXECUTE] key is
pressed while it is highlighted, the operation is stopped.
(Loads to be selected.)
∗
The setup contents of this simulation remain unchanged until
the power is turned off. When this simulation is executed, SIM 7-
8 (Warm-up time display setting) is canceled.
the power is turned off. When this simulation is executed, SIM 7-
8 (Warm-up time display setting) is canceled.
(Set content)
5
-4
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the operations of the discharge lamp
and its control circuit.
and its control circuit.
/
Section
Process (Photoconductor, developing,
transfer, cleaning)
transfer, cleaning)
Others
Item
Operation
Operation/
Procedure
Procedure
1. Select the target discharge lamp with the [K], [C],
[M], and [Y] keys. (K: Black, C: Cyan,
M: Magenta, Y: Yellow)
M: Magenta, Y: Yellow)
6
6
-1
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the operations of the loads (clutches
and solenoids) in the paper transport system,
transfer, and fusing, and the control circuit.
and solenoids) in the paper transport system,
transfer, and fusing, and the control circuit.
Section
Paper transport (paper exit, switchback, transport),
transfer, fusing
transfer, fusing
Item
Operation
Operation/
Procedure
Procedure
1. The names of the loads that can be checked are
displayed. Select the load to be checked with the
key, and the selected load is highlighted.
key, and the selected load is highlighted.
2. Press the [EXECUTE] key. The selected load
starts the operation. During the operation of the
load, the [EXECUTE] key is highlighted. If the
[EXECUTE] key is pressed while it is highlighted,
the operation is stopped.
load, the [EXECUTE] key is highlighted. If the
[EXECUTE] key is pressed while it is highlighted,
the operation is stopped.
CPFC
Cassette transport clutch
TRC
Cassette paper feed clutch
MTRC
Manual paper feed clutch
MPFC
Manual transport clutch
GSS
Paper exit gate select solenoid
RRM
Resist roller motor (PSM)
PFM
Paper feed motor (Vertical transport)
FUM
Fusing motor
BLUM
Lift motor
BLUM (R)
Lift motor (Reverse rotation/waste toner transport
motor)
motor)
OSM
Offset motor (Job separator)
CARB
Calibration plate
6
-2
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the operations of the fan motors and
the control circuits.
the control circuits.
Section
Others
Item
Operation
Operation/
Procedure
Procedure
1. The loads that can be checked are displayed.
Select one to be checked.
VFM1
Fusing fan 1
VFM2
Fusing fan 2
PSFM
Power fan
PRTCFM
Process exhaust fan
SIROCCOFM
Sirocco fan
7
7
-1
Purpose
Setting/Operation test/check
Function
(Purpose)
(Purpose)
Used to set the aging conditions.
Item
Operation
Operation/
Procedure
Procedure
1. Press each corresponding key to set for the
aging operation.
(Set items of each key)
The selected key is highlighted.
(Set items of each key)
The selected key is highlighted.
2. Press the [EXECUTE] key.
Aging is set and the display returns to the
simulation main code entry menu.
simulation main code entry menu.
[AGING]
Jam detection setup
[INTERVAL]
Intermittent setup
[MISFEED DISABLE]
Jam detection YES/NO setup
[FUSING DISABLE]
Fusing operation YES/NO detection
[WARMUP DISABLE]
Warm-up saving setup
[DV CHECK DISABLE] Developing tank detection YES/NO setup
[SHADING DISABLE]
[SHADING DISABLE]
Shading saving setup
[CCD GAIN FREE]
No setting of CCD gain adjustment
AR-C170M SIMULATION 9 - 18
∗
The interval time set range is 1 - 999 sec. [Default: 3]
∗
The setup contents of this simulation remain unchanged until
the power is turned off. When SIM 7-1 is executed, the setup
contents are canceled.
the power is turned off. When SIM 7-1 is executed, the setup
contents are canceled.
Copying is performed with the color selected in procedure 1).
When no print color is selected, the operation is made with the all
colors.
When no print color is selected, the operation is made with the all
colors.
The [EXECUTE] key is highlighted. When the adjustment value
entered in procedure 2) and the corresponding voltage is
outputted.
entered in procedure 2) and the corresponding voltage is
outputted.
The voltage is outputted for 30sec, then the [EXECUTE] key
returns to the normal display. When the EXECUTE key is pressed
during output of the voltage, the output is stopped and the
[EXECUTE] key returns to the normal display.
returns to the normal display. When the EXECUTE key is pressed
during output of the voltage, the output is stopped and the
[EXECUTE] key returns to the normal display.
(Set value)
7
-6
Purpose
Setting/Operation test/check
Function
(Purpose)
(Purpose)
Used to set the cycle of intermittent aging.
Item
Operation
Operation/
Procedure
Procedure
1. Enter the interval aging cycle time (sec) with the
10-key pad.
2. Press [OK] key (or B/W Start key, Color Start
key) to set the entered cycle time.
7
-8
Purpose
Setting/Operation test/check
Function
(Purpose)
(Purpose)
Used to set Yes/No of warm-up time display.
Item
Operation
Operation/
Procedure
Procedure
Press the [EXECUTE] key to set the warm-up time
display.
When the [EXECUTE] key is pressed, the warm-up
time display setting is executed and the display
returns to the simulation main code entry display.
display.
When the [EXECUTE] key is pressed, the warm-up
time display setting is executed and the display
returns to the simulation main code entry display.
7
-9
Purpose
Setting/Operation test/check
Function
(Purpose)
(Purpose)
Used to check the image quality and operations of
each color.
each color.
Section
Others
Item
Picture quality
Operation/
Procedure
Procedure
1. Select the color of image quantity and operation
check with the key.
2. Press the START key.
8
8
-1
Purpose
Adjustment/Operation test/check
Function
(Purpose)
(Purpose)
Used to check and adjust the operations of the
developing bias voltage of each color and the
control circuit.
developing bias voltage of each color and the
control circuit.
Section
Process
(Photoconductor, developing, transfer, cleaning)
(Photoconductor, developing, transfer, cleaning)
Operation/
Procedure
Procedure
(
The developing bias output voltage in each of the
following print modes can be adjusted and checked.)
(Adjustment range)
0 – 585 (Default: See below)
(Adjustment range)
0 – 585 (Default: See below)
1. Select the color mode with the [K], [C], [M], or [Y]
key.
2. Select the copy mode with the scroll key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
Color
Item
Operation mode
Adjustment value
Developing bias voltage
Monitor (High voltage PWB)
Pin
No.
Actual
voltage
Adjustment
range
Specified value
(Default)
Monitor voltage
(Specified value)
Connector
K
A: HIGH SPEED
High speed (117mm/s) (B & W)
0 – 585
215
3.94 ± 0.1V
CNMONK
3
–215v
B: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
0 – 585
215
3.94 ± 0.1V
CNMONK
3
–215v
C: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
(Special paper)
0 – 585
215
3.94 ± 0.1V
CNMONK
3
–215v
C
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
0 – 585
265
5.76 ± 0.1V
CNMON
1
–265v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
(Special paper)
0 – 585
265
5.76 ± 0.1V
CNMON
1
–265v
M
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
0 – 585
265
5.76 ± 0.1V
CNMON
5
–265v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
(Special paper)
0 – 585
265
5.76 ± 0.1V
CNMON
5
–265v
Y
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
0 – 585
240
4.75 ± 0.1V
CNMON
9
–240v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
(Special paper)
0 – 585
240
4.75 ± 0.1V
CNMON
9
–240v
AR-C170M SIMULATION 9 - 19
2. Select the print mode with [
↑
] key and [
↓
] key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
The [EXECUTE] key is highlighted, the adjustment value entered
in procedure 2 is set, and the voltage corresponding to the set
value is outputted.
4. Press the [EXECUTE] key.
The [EXECUTE] key is highlighted, the adjustment value entered
in procedure 2 is set, and the voltage corresponding to the set
value is outputted.
The voltage is supplied for 30 sec, then the [EXECUTE] key
returns to the normal display.
returns to the normal display.
If the [EXECUTE] key is pressed while the voltage is supplied, the
voltage output is stopped and the [EXECUTE] key returns to the
normal display.
voltage output is stopped and the [EXECUTE] key returns to the
normal display.
(Set value)
The [EXECUTE] key is highlighted, the adjustment value entered
in procedure 2 is set, and the voltage corresponding to the set
value is outputted.
in procedure 2 is set, and the voltage corresponding to the set
value is outputted.
The voltage is supplied for 30 sec, then the [EXECUTE] key
returns to the normal display.
returns to the normal display.
If the [EXECUTE] key is pressed while the voltage is supplied, the
voltage output is stopped and the [EXECUTE] key returns to the
normal display.
voltage output is stopped and the [EXECUTE] key returns to the
normal display.
In this simulation, when the transfer voltage is supplied, the
transfer belt and the OPC drum rotates at the same time.
Therefore, the above parts are not damaged.
transfer belt and the OPC drum rotates at the same time.
Therefore, the above parts are not damaged.
8
-2
Purpose
Adjustment/Operation test/check
Function
(Purpose)
(Purpose)
Used to check and adjust the operation of each print
mode main charger grid voltage and the control
circuit.
mode main charger grid voltage and the control
circuit.
Section
Process
(Photoconductor, developing, transfer, cleaning)
(Photoconductor, developing, transfer, cleaning)
Operation/
Procedure
Procedure
(The charging/grid output voltage in each print mode
can be adjusted and checked.)
1. Select the color mode with the [K], [C], [M], and
can be adjusted and checked.)
1. Select the color mode with the [K], [C], [M], and
[Y] keys.
∗
When [EXECUTE] key is pressed, the display is
highlighted and the currently set voltage is
outputted.
highlighted and the currently set voltage is
outputted.
Color
Item Operation
mode
Adjustment value
Main charger grid voltage
Monitor (High voltage PWB)
Pin
No.
Actual
voltage
Adjustment
range
Specified
value (Default)
Monitor voltage
(Specified value)
Connector
K
A: HIGH SPEED
High speed (117mm/s) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
B: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
C: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
(Special paper)
180 – 700
620
53.5 ± 0.2v
CNMONK
1
–620v
C
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
3
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
(Special paper)
180 – 700
620
53.5 ± 0.2v
CNMON
3
–620v
M
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
7
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
(Special paper)
180 – 700
620
53.5 ± 0.2v
CNMON
7
–620v
Y
A: MIDDLE SPEED
Middle speed (78mm/s) (Color) (B & W)
180 – 700
620
53.5 ± 0.2v
CNMON
11
–620v
B: LOW SPEED
Low speed (58.5mm/s) (Color) (B & W)
(Special paper)
(Special paper)
180 – 700
620
53.5 ± 0.2v
CNMON
11
–620v
8
-6
Purpose
Adjustment/Operation test/check
Function
(Purpose)
(Purpose)
Used to check and adjust the operation of the
transfer charger current and the control circuit.
transfer charger current and the control circuit.
Section
Process (Photoconductor, developing,
transfer, cleaning)
transfer, cleaning)
Transfer
Operation/
Procedure
Procedure
1. Select the color mode with the [K], [C], [M], and
[Y] keys.
2. Select the copy mode with the scroll key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
3. Enter the adjustment value with the 10-key pad.
4. Press the [EXECUTE] key.
AR-C170M SIMULATION 9 - 20
(Items to be selected/replaced)
(Check item)
While the load operates, the [EXECUTE] key is highlighted.
When the [EXECUTE] key is pressed under this state, the
operation of the load can be interrupted.
When the [EXECUTE] key is pressed under this state, the
operation of the load can be interrupted.
Item
Print mode
Standard setting value
(Default)
Adjustment
range
Output voltage (Kv)
K
C
M
Y
K
C
M
Y
A
PLAIN SPX CL
Color
Normal paper
78mm/s
153
141
119
119
51 - 255
2
2
2
2
B
PLAIN DPX CL
Color
Normal paper(Duplex mode)
78mm/s
168
155
129
129
2.3
2.3
2.3
2.3
C
OHP1 CL
Color
Transparency film 1
78mm/s
204
187
153
153
3
3
3
3
D
OHP2 CL
Color
Transparency film 2
58.5mm/s
137
150
153
163
1.7
2.2
3
3.3
E
HEAVY P1 SPX CL
Color
Thick paper 1
58.5mm/s
158
146
122
122
2.1
2.1
2.1
2.1
F
HEAVY P1 DPX CL
Color
Thick paper 1(Duplex mode)
58.5mm/s
188
173
142
142
2.7
2.7
2.7
2.7
G
HEAVY P2 CL
Color
Thick paper 2
58.5mm/s
173
159
132
132
2.4
2.4
2.4
2.4
H
ENVELOPE CL
Color
Envelope
78mm/s
153
141
119
119
2
2
2
2
I
PLAIN SPX BW
B & W
Normal paper
117mm/s
168
2.3
J
PLAIN DPX BW
B & W
Normal paper(Duplex mode)
117mm/s
178
2.5
K
OHP1 BW
B & W
Transparency film 1
78mm/s
204
3
L
OHP2 BW
B & W
Transparency film 2
58.5mm/s
137
1.7
M
HEAVY P1 SPX BW
B & W
Thick paper 1
58.5mm/s
147
1.9
N
HEAVY P1 DPX BW
B & W
Thick paper 1(Duplex mode)
58.5mm/s
178
2.5
O
HEAVY P2 BW
B & W
Thick paper 2
58.5mm/s
163
2.2
P
ENVELOPE BW
B & W
Envelope
117mm/s
168
2.3
9
9
-2
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the operation of the sensors and
detectors in the inverter/duplex section and the
control circuit.
detectors in the inverter/duplex section and the
control circuit.
Section
Inverter/Duplex
Item
Operation
Operation/
Procedure
Procedure
The operations of sensors and detectors in the
inverter/duplex section are displayed.
The active sensors and detectors are highlighted.
inverter/duplex section are displayed.
The active sensors and detectors are highlighted.
BPPD1
Inverter transport detection 1
BPPD2
Inverter transport detection 2
BPRD
Inverter reverse detection
BPOD
Inverter paper exit detection
BPFD
Inverter full detection
BDD1
Inverter door detection 1
BDD2
Inverter door detection 2
APPD1
ADU transport detection 1
APPD2
ADU transport detection 2
APHPS
ADU alignment plate home position
POD1
Machine paper exit detection
BYSET
Inverter installation detection
ADUDSET
ADU installation detection
ADUSET
ADU door open/close detection
9
-3
Purpose
Operation test/check
Function
(Purpose)
(Purpose)
Used to check the operations of the loads (motor,
clutch, solenoid) in the inverter/duplex section and
the control circuits.
clutch, solenoid) in the inverter/duplex section and
the control circuits.
Section
Inverter/Duplex
Item
Operation
Operation/
Procedure
Procedure
1. Select the load to be checked with the 10-key
pad.
2. Press the [EXECUTE] key.
The load selected in procedure 1 operates.
BIM
Inverter paper entry motor
BRMFW
Inverter reverse motor (Normal rotation)
BRMRV
Inverter reverse motor (Reverse rotation)
BGSOL
Inverter gate solenoid
BTMFW
Inverter transport motor (Normal rotation)
BTMRV
Inverter transport motor (Reverse rotation)
ATM
ADU transport motor
APAM
ADU alignment motor
ATRC
ADU transport clutch
Click on the first or last page to see other AR-C170 (serv.man26) service manuals if exist.