JBL SUB 250P (serv.man2) EMC - CB Certificate ▷ View online
Page 28 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
A.10
Insulation requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
NETWORKS
N/A
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
N/A
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.7
Lithium batteries meet permissible temp rise in
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
N/A
L. 9
Electric shock hazard under normal operating
conditions
conditions
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L.10
Insulation requirements
N/A
L. 10.3.2
High frequency puls ignition
N/A
L. 12
Mechanical strength
N/A
Page 29 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
impact test
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
to be a POTENTIAL IGNITION SOURCE
N/A
Page 30 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
7.1
TABLE: temperature rise measurements:
P
Power consumption in the OFF/Stand-by mode of
the functional switch (W) ......................................... :
the functional switch (W) ......................................... :
--
Cond.
Un (V)
Hz
In (A)
Pn (W) Uout (V) Pout (W) Operating Condition / Status
For model SUB 250P/100
1.
90
60
0.82
44.6
--
--
Maximum normal load
2.
100
60
0.77
44.3
--
--
Maximum normal load
3.
120
60
0.68
43.0
--
--
Maximum normal load
4.
132
60
0.64
43.0
--
--
Maximum normal load
For model SUB 250P/230
5.
198
50
0.38
40.6
--
--
Maximum normal load
6.
198
60
0.38
40.6
--
--
Maximum normal load
7.
220
50
0.35
40.8
--
--
Maximum normal load
8.
220
60
0.35
40.8
--
--
Maximum normal load
9.
240
50
0.34
41.2
--
--
Maximum normal load
10.
240
60
0.34
41.2
--
--
Maximum normal load
11.
254
50
0.33
41.4
--
--
Maximum normal load
12.
254
60
0.33
41.4
--
--
Maximum normal load
13.
264
50
0.32
41.7
--
--
Maximum normal load
14.
264
60
0.32
41.7
--
--
Maximum normal load
Loudspeaker impedance (Ω) .................................. :
--
—
Several loudspeaker systems ................................. :
--
N/A
Marking of loudspeaker terminals ........................... :
--
N/A
Temperature Rise dT of Part
dT (K)
Limit max dT (K)
Test Condition No.
No _1_
No _4_
No _6_
No _14_
--
Model
SUB 250P/100
SUB 250P/230
--
01. T2 coil
65.5
68.7
55.7
66.6
75
02. T2 core
63.8
67.2
55.5
65.1
75
03. T1 coil
48.5
55.1
41.5
53.3
75
04. T1 core
47.2
52.6
40.9
51.0
75
05. DT1 coil
45.2
47.8
38.3
46.6
75
06. DT1 core
43.6
45.6
36.6
44.5
75
07. CT1 primary coil
60.0
64.7
52.6
63.5
75
08. CT1 secondary coil
59.8
64.2
52.9
62.8
75
09. Body of CY4
43.5
46.7
37.6
45.3
90
10. Body of U2
43.3
47.2
38.2
45.8
65
11. LF2 coil
30.2
28.5
22.2
23.9
95
12. Body of CX1
25.7
25.4
13.0
17.3
50
Page 31 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
13. Body of CX2
29.2
28.6
22.2
24.6
50
14. Body of CY3
24.9
24.5
19.9
22.7
90
15. Body of ZNR1
28.4
28.0
21.0
23.5
--
16. Body of C1
35.6
36.2
29.7
33.5
70
17. PWB near TH1
37.1
35.6
25.3
28.3
70
18. PWB near BR1
30.9
29.6
24.7
26.6
70
19. PWB near Q6
41.1
45.8
34.2
44.4
70
20. L2 coil
33.1
35.8
26.3
34.2
70
21. PWB near D8
39.1
40.1
32.9
38.1
70
22. CN1 connecter near L
22.4
22.5
17.5
20.1
50
14.5
14.5
11.8
13.1
35
24. PWB near IC1 (Amplifier board)
44.7
44.0
32.5
43.1
70
25. L1 coil (Amplifier board)
45.0
44.9
39.4
43.6
70
20.2
20.9
16.7
20.5
45
27. External metal enclosure near IC1 ( of
Amplifier board)
Amplifier board)
22.2
21.7
18.1
20.9
40
28. Power switch
11.0
10.5
9.0
10.1
50
29. Ambient
23.6
o
C
24.5
o
C
24.6
o
C
24.6
o
C
--
Note(s):
For the max. temperature rise is calculated as follows which based upon maximum working ambient of
35°C:
For the max. temperature rise is calculated as follows which based upon maximum working ambient of
35°C:
Winding components:
- insulated with polyurethane resins: ∆Tmax = 85 K-10-(35-35) K = 75 K
Electrolyte capacitor or components with:
- insulated with polyurethane resins: ∆Tmax = 85 K-10-(35-35) K = 75 K
Electrolyte capacitor or components with:
- max. absolute temp. of 130°C:
∆Tmax = (125-35) K = 95 K
- max. absolute temp. of 125°C:
∆Tmax = (125-35) K = 90 K
- max. absolute temp. of 105°C:
∆Tmax = (105-35) K = 70 K
- max. absolute temp. of 100°C:
∆Tmax = (100-35) K = 65 K
- max. absolute temp. of 85°C:
∆Tmax = (85-35) K = 50 K
- max. absolute temp. of 80°C:
∆Tmax = (80-35) K = 45 K
- max. absolute temp. of 70°C:
∆Tmax = (70-35) K = 35 K
User touchable surface with:
- Plastic part (knob): ∆Tmax = 50-(35-35)= 50 K
- Plastic part (knob): ∆Tmax = 50-(35-35)= 50 K
- Metal part (enclosure): ∆Tmax = 40-(35-35)= 40 K
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ....................... :
—
Ambient temperature t2 (
o
C) ....................... :
—
Temperature rise dT of winding:
dT = (R
2
– R
1
) x (234.5 + t1) – (t2 – t1)
R
1
R
1
(Ω)
R
2
(Ω)
dT (K)
Limit max (K) Insulation class
Click on the first or last page to see other SUB 250P (serv.man2) service manuals if exist.