JBL SUB 250P (serv.man2) EMC - CB Certificate ▷ View online

Page 16 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
9 – 1 
212 
344 
9 – 2 
213 
360 
9 – 3 
213 
360 
9 – 4 
213 
349 
9 – 5 
213 
348 
10 – 1 
240 
456 
10 – 2 
231 
432 
10 – 3 
242 
464 
10 – 4 
240 
456 
10 – 5 
238 
460 
(Input: 120V) 
6 – 1 
167 
180 
6 – 2 
166 
182 
6 – 3 
168 
270 
6 – 4 
167 
186 
6 – 5 
167 
202 
8 – 1 
162 
303 
8 – 2 
161 
218 
8 – 3 
168 
313 
8 – 4 
164 
300 
8 – 5 
166 
292 
9 – 1 
165 
172 
9 – 2 
163 
191 
9 – 3 
162 
187 
9 – 4 
164 
172 
9 – 5 
165 
175 
10 – 1 
195 
290 
10 – 2 
181 
266 
10 – 3 
198 
294 
10 – 4 
193 
290 
10 – 5 
192 
284 
For T2 
Location 
Vrms 
Vpeak 
(Input: 240V) 
1 – 7 
256 
416 
1 – 9 
154 
268 
1 – 10,11 
185 
344 
3,4 – 7 
168 
304 
3,4 – 9 
145 
208 
3,4 – 10,11 
145 
232 
Page 17 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
5 – 7 
151 
252 
5 – 9 
152 
258 
5 – 10,11 
140 
180 
6 – 7 
39.4 
90 
6 – 9 
35.4 
84 
6 – 10,11 
32 
64 
(Input: 120V) 
1 – 7 
176 
252 
1 – 9 
64.7 
104 
1 – 10,11 
120 
178 
3,4 – 7 
92.5 
140 
3,4 – 9 
22.8 
48 
3,4 – 10,11 
36.7 
68 
5 – 7 
55.4 
94 
5 – 9 
59.2 
98 
5 – 10,11 
9.76 
24 
6 – 7 
22.5 
46 
6 – 9 
16.4 
38 
6 – 10,11 
8.6 
24 
For CT1 
Location 
Vrms 
Vpeak 
(Input: 240V) 
3 – 1 
185 
340 
3 – 2 
185 
340 
4 – 1 
185 
340 
4 – 2 
186 
340 
(Input: 120V) 
3 – 1 
120 
178 
3 – 2 
120 
178 
4 – 1 
120 
178 
4 – 2 
121 
178 
For DT1 
Location 
Vrms 
Vpeak 
(Input: 240V) 
1 – 8 
217 
354 
1 – 9 
214 
346 
2 – 8 
182 
340 
2 – 9 
188 
356 
3 – 8 
217 
376 
3 – 9 
216 
360 
Page 18 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
4 – 8 
188 
352 
4 – 9 
193 
368 
(Input: 120V) 
1 – 8 
165 
184 
1 – 9 
164 
181 
2 – 8 
117 
178 
2 – 9 
125 
180 
3 – 8 
165 
198 
3 – 9 
157 
186 
4 – 8 
125 
182 
4 – 9 
134 
194 
For others 
Location 
Vrms 
Vpeak 
(Input: 240V) 
U2 (3 – 1) 
216 
352 
U2 (3 – 2) 
215 
348 
U2 (4 – 1) 
215 
348 
U2 (4 – 2) 
215 
348 
Under CY4 
213 
344 
T2 pin 1 to 
C24 
227 
424 
(Input: 120V) 
U2 (3 – 1) 
157 
174 
U2 (3 – 2) 
157 
176 
U2 (4 – 1) 
156 
170 
U2 (4 – 2) 
157 
172 
Under CY4 
156 
170 
T2 pin 1 to 
C24 
175 
250 
13.3 
Clearances  
See below. 
13.3.1 
General  
See below. 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9 ............. : 
Considered. 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10  
 
N/A 
13.3.4 
Measurement of transient voltages  
 
13.4 
Creepage distances  
See appended table 13. 
 
Creepage distances greater than table 11 minimum 
values  
See appended table 13. 
13.5 
Printed boards  
 
N/A 
Page 19 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10  
 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664-3 (basic insulation only)  
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4  
See appended table 13. 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 
N/A 
 
Temperature cycle test and dielectric strength test  
 
N/A 
 
500V test for transformers, magnetic coupler and 
similar devices, if insulation is relied upon for safety 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts 
not conductively connected to the mains, clearances 
and creepage distances as in table 12  
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
Photo coupler is an approved 
component, see clause 14.11. 
 
14 
Components 
14.1 
Resistors  
 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts  
 
N/A 
 
Resistors separately approved  ............................... : 
 
N/A 
14.2 
Capacitors and RC units  
Certified capacitors used. 
 
Capacitors separately approved  : 
Yes. 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 
edition YY: 
The Y1-capacitor (CY1 CY2, 
CY3, CY4) is used between 
hazardous live and non-
hazardous live also approved 
according to IEC 60384-14. 
See appended table 14. 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 
edition YY: 
The X-capacitor (CX1, CX2) is 
conductively connected 
between the mains and 
approved according to IEC 
60384-14. See appended table 
14. 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ...................... : 
 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC 60384-1, 4.38 category B or better  ................. : 
The capacitor which volume 
exceeding 1750 mm³ is metal 
cased. 
Page of 112