JBL SUB 250P (serv.man2) EMC - CB Certificate ▷ View online
Page 12 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Reinforced insulation > 0,4 mm (mm) .................... :
- Transformer (CT1 and T1)
bobbin thickness is 0.8mm
min.
min.
- Plastic chassis thickness
2.5mm
P
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
See below.
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
See appended table 10.3.
P
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
N/A
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Double insulation complied
with 8.9 and 10.3.
with 8.9 and 10.3.
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Double insulation complied
with 8.9 and 10.3.
with 8.9 and 10.3.
P
8.11
Detaching of wires
No detaching of wires.
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No undue reduction of
creepages or clearance
distances.
creepages or clearance
distances.
P
Vibration test carried out ......................................... :
Yes
P
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
Complied.
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
No risk of mechanical damage
to the insulation of the wires.
to the insulation of the wires.
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
Triple insulated wires used in
T1. See appended table 14.
T1. See appended table 14.
P
Page 13 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8.18
Endurance test as required by 8.17
Certified source used.
N/A
8.19
Disconnection from the mains
See below.
P
8.19.1
Disconnect device
See Engineering
Considerations
Considerations
and
Markings and Instructions.
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
N/A
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
N/A
9.1.1.1
a) Open circuit voltages
See appended table.
P
b) Touch current measured from terminal devices
using the network in annex D ................................. :
using the network in annex D ................................. :
See appended table.
P
c) Discharge not exceeding 45 µC
P
d) Energy of discharge not exceeding 350 mJ
P
9.1.1.2
Test with test finger and test probe
The test probe B cannot touch
any hazardous live part.
any hazardous live part.
The test probes 18 and 19 of
IEC 61032 cannot touch any
hazardous live part.
IEC 61032 cannot touch any
hazardous live part.
P
9.1.2
No hazardous live shafts of knobs, handles or levers Complied.
P
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
No opening on whole
equipment.
equipment.
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................. :
of the mains plug; voltage (V) after 2 s .................. :
For input 132Vdc:7Vdc after
2s.
2s.
For input 264Vac: 22Vdc after
2s.
2s.
P
If C is not greater than 0,1 µF no test needed
N/A
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
Applied to enclosure.
P
Page 14 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
b) Test hook of fig. 4 for 10 s (20 N)
Complied.
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
250 N applied.
P
9.2
No hazard after removing a cover by hand
No cover can be removed by
hand.
hand.
N/A
10
Insulation requirements
P
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
surge test for basic and 4 MΩ min. for reinforced
insulation ................................................................. :
See appended table.
P
10.2
Humidity treatment 48 h or 120 h ........................... :
120 h
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
See appended table.
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
See appended table.
P
11
Fault conditions
P
11.1
No shock hazard under fault condition
See appended table.
P
11.2
Heating under fault condition
See appended table.
P
Flames extinguish within 10 seconds
No flames.
N/A
No hazard from softening solder
No softerning solder.
N/A
Soldered terminations not used as protective
mechanism
mechanism
Soldered terminals are not
used as protective mechanism.
used as protective mechanism.
P
11.2.1
Measurement of temperature rises
See appended table.
P
11.2.2
Temperature rise of accessible parts
See appended table.
P
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
printed boards, providing electrical insulation
See appended table.
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
N/A
11.2.5
Temperature rise of windings
See appended table.
P
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
the limits of table 3 by max. 100 K for max. 5 min
Not exceed the limits. See
appended table.
appended table.
P
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
N/A
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................ :
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ................ :
N/A
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
N/A
Page 15 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".
See appended table.
P
12
Mechanical strength
P
12.1.1
Bump test where mass >7 kg
No damage.
P
12.1.2
Vibration test
No damage.
P
12.1.3
Impact hammer test
Test was made on every weak
point of the enclosure and all
protruded parts; No damage,
complied with 10.3.
point of the enclosure and all
protruded parts; No damage,
complied with 10.3.
P
Steel ball test
No damage, complied with
10.3.
10.3.
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg
N/A
12.1.5
Thermoplastic enclosures stress relief test
80°C applied. No damage.
P
12.2
Fixing of knobs, push buttons, keys and levers
N/A
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
P
13.1
Clearances in accordance with 13.3
See appended table.
P
Creepage distances in accordance with 13.4
See appended table.
P
13.2
Determination of working voltage
For T1
P
Location
Vrms
Vpeak
(Input: 240V)
6 – 1
217
352
6 – 2
220
440
6 – 3
218
352
6 – 4
218
352
6 – 5
218
364
8 – 1
213
464
8 – 2
213
388
8 – 3
215
480
8 – 4
214
464
8 – 5
213
460