Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
Not soldered to conductors of a printed circuit board   The conductors of non-
detachable power supply cord 
are reliable soldered to the 
switch and conductors of AC 
connector. 
 
Adequate clearances and creepage distances 
between connections should a wire break away  
The force 5 N performed in any 
direction to the connection. No 
hazards. 
 
Wire secured by additional means to the  
conductor   
The soldered connections are 
sleeved. 
15.3.3 
Screws and nuts clamping conductors have 
adequate threads: ISO 261, ISO 262 or similar  
 
N/A 
15.3.4 
Soldered conductors wrapped around terminal prior 
to soldering or held in place by additional means  
The conductors of non-
detachable power supply cord 
connected to power supply 
board by quick connector. 
 
Clamping of conductor and insulation if not soldered 
or held by screws  
 
N/A 
15.3.5 
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current of 
the equipment  
No such terminals. 
N/A 
15.3.6 
Terminals to 15.3.3 have sizes required by table 16    
N/A 
15.3.7 
Terminals clamp conductors between metal and 
have adequate pressure  
 
N/A 
 
Terminals designed to avoid conductor slipping out 
when tightened or loosened  
 
N/A 
 
Terminals adequately fixed to avoid loosening when 
the clamping is tightened or loosened and stress on 
internal wiring is avoided  
 
N/A 
15.3.8 
Terminals carrying a current more than 0,2 A: 
contact pressure not transmitted by insulating 
material except ceramic  
Contact pressure of terminals 
is not transmitted by insulating 
material. 
15.3.9 
Termination of non-detachable cords: wires 
terminated near to each other  
The conductors of terminals 
are insulated by sleeve. 
 
Terminals located and shielded: test with 8 mm 
strand  
 
N/A 
15.4 
Devices forming a part of the mains plug  
Not direct plug-in equipment. 
N/A 
15.4.1 
No undue strain on mains socket-outlets  
 
N/A 
15.4.2 
Device complies with standard for dimensions of 
mains plugs  
 
N/A 
15.4.3 
Device has adequate mechanical strength (tests 
a,b,c)  
 
N/A 
 
16 
External flexible cords 
Page 25 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  ............................................................ : 
See table 14. 
 
Non-detachable cords for Class I have green/yellow 
core for protective earth  
Class II. 
N/A 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment  
0.75mm
2
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength  
 
N/A 
 
b) Flexible cords not complying with 16.1, withstand 
bending and mechanical stress (3.2 of IEC 60227-2)  
 
N/A 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions  
 
N/A 
16.5 
Adequate strain relief on external flexible cords  
Cord anchorage used on 
external flexible cord. It 
provided as adequate strain 
relief and after stress relief. 
 
Not possible to push cord back into equipment  
Complied. 
 
Strain relief device unlikely to damage flexible  
cord  
Complied. 
 
For mains cords of Class I equipment, hazardous 
live conductors become taut before earth conductor  
 
N/A 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use  
See sub-clause 16.5. 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet to 
IEC 60320-1  
 
N/A 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord  
 
N/A 
 
17 
Electrical connections and mechanical fixings 
17.1 
Torque test to table 20  
See below. 
 
- screws into metal: 5 times  
 
N/A 
 
- screws into non-metallic material: 10 times  
1.8 Nm. 
17.2 
Correct introduction into female threads in non-
metallic material  
 
N/A 
17.3 
Cover fixing screws: captive  
See below. 
Page 26 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
Non-captive fixing screws: no hazard when replaced 
by a screw whose length is 10 times its diameter  
Complied. 
17.4 
No loosening of conductive parts carrying a current 
> 0,2 A  
All termination of conductors is 
reliably fixed by quick 
connection so that a loosening 
of the terminal connection is 
unlikely. 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a current 
> 0,2 A  
No contact pressure through 
plastic material. 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0,2 A with screw terminals not 
consolidated by solder  
 
N/A 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous  
 
N/A 
17.8 
Fixing devices for detachable legs or stands  
provided  
 
N/A 
17.9 
 
N/A 
 
18 
Mechanical strength of picture tubes and protection against the effects of 
implosion 
N/A 
18.1 
Picture tube separately approved to IEC 61965  .... : 
 
N/A 
 
Picture tube separately approved to 18.2  .............. : 
 
N/A 
18.2 
Non-intrinsically protected tubes tested to 18.2 
 
N/A 
 
19 
Stability and mechanical hazards 
 
Mass of the equipment exceeding 7 kg  ................. : 
15kg. 
 
Apparatus intended to be fastened in place – 
suitable instructions  ................................................ : 
 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal  
No overturn. 
19.2 
100 N force applied vertically downwards  
No overturn. 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability  
No overturn. 
19.4 
Edges or corners not hazardous  
The edges and corners are 
smoothed. 
19.5 
Glass surfaces (exc.laminated) with an area 
exceeding 0,1 m² or maximum dimension 
> 450 mm, pass the test of 19.5.1  
 
N/A 
19.6 
Wall or ceiling mountings adequate  
 
N/A 
 
20 
Resistance to fire 
20.1 
Electrical components and mechanical parts  
Page 27 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width  
All components were contained 
in a fire enclosure of material 
V-1 and no opening. See 
appended table 14 for 
enclosure material. 
 
b) Exemption for small components as defined in 
20.1  
All components are mounted 
on a PCB with V-0 or better. 
20.1.1 
Electrical components meet the requirements of 
Clause 14 or 20.1.4  
See appended table 14. 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, or 
located within the areas mentioned in Table 21, not 
contributing to the spread of fire  
 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage between 
50 V and 400 V (peak) a.c. or d.c. meets V-1 or 
better to IEC 60707, unless used in a fire enclosure  
PCB is rated V-0 min. 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707  
 
N/A 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21  
 
N/A 
 
Components and parts as above but shielded from a 
potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13  
 
N/A 
 
Apparatus with voltages >4kV under normal 
operating conditions and distances to the enclosure 
exceed those specified Table 21, flammability 
classification HB40 or better is required for the 
enclosure  
 
N/A 
20.2 
Fire enclosure  
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to V-1  
 
N/A 
20.2.2 
 
N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure  
 
N/A 
 
Annex A, Additional requirements for apparatus with protection against 
splashing water 
N/A 
A.5 
Marking and instructions 
 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply  
 
N/A 