Page 32 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
7.2 
TABLE: softening temperature of thermoplastics 
N/A 
 
Temperature T of part 
T - normal con-
ditions (
o
C) 
T - fault condi-
tions (
o
C) 
Min T softening 
(
o
C) 
 
 
 
 
 
 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
P 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
Line to neutral 
 
999 
 
Between parts separated by basic or supplementary insulation 
-- 
Between parts separated by double or reinforced insulation 
Unit: Input to output 
Unit: Input to metal cover 
Unit: Input to wooden enclosure with foil 
T1: Input to output 
T1: Output to core 
T2: Input to output 
T2: Input to core 
T2: Output to core 
CT1: Input to output 
CT1: Input to core 
CT1: Output to core 
DT1: Input to output 
DT1: Input to core 
DT1: Output to core 
1 layers insulation tape used for all transformers  
Tubes 
 
999 
999 
999 
999 
999 
999 
999 
999 
999 
999 
999 
999 
999 
999 
999 
999 
 
10.3 
TABLE: electric strength measurements 
P 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Between mains poles (primary fuse disconnected) 
Line to neutral 
2120 
No 
Between parts separated by basic or supplementary insulation 
-- 
-- 
Page 33 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Between parts separated by double or reinforced insulation 
Unit: Input to output 
Unit: Input to metal cover 
Unit: Input to wooden enclosure with foil 
T1: Input to output 
T1: Output to core 
T2: Input to output 
T2: Input to core 
T2: Output to core 
CT1: Input to output 
CT1: Input to core 
CT1: Output to core 
DT1: Input to output 
DT1: Input to core 
DT1: Output to core 
1 layers insulation tape used for all transformers  
Tubes 
 
4240 
4240 
4240 
4240 
4240 
4240 
2249 
2249 
4240 
2047 
2047 
4240 
2146 
2146 
4240 
4240 
No 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage  .............. :  See below 
— 
 
Frequency (Hz) ........................................................ :  -- 
— 
 
Ambient temperature (
o
C)  ....................................... :  See below. 
— 
 
No. 
Component 
Fault 
dT (K) / Component 
Other results 
(include description and test duration) 
Model SUB 250P/230 (input: 264Vac) 
BR1 
Short 
-- 
Input current= 0.34A to 0A. 
Fuse open instantly. No hazards. 
C1 
Short 
-- 
Input current= 0.34A to 0A. 
Fuse open instantly. No hazards. 
U2 (1 – 2) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
U2 (3 – 4) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
U2 pin 1 
Open 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
U2 pin 3 
Open 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
Q6 (G – D) 
Short 
--
 
Input current= 0.34A to 0A. 
Fuse open instantly. No hazards. 
Q6 (G – S) 
Short 
--
 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
Page 34 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
No. 
Component 
Fault 
dT (K) / Component 
Other results 
(include description and test duration) 
Q6 (D – S) 
Short 
-- 
Input current= 0.34A to 0A. 
Fuse open instantly, no hazards. 
10 
Q7 (G – D) 
Short 
-- 
Input current= 0.34A to 0A. 
Fuse open instantly, no hazards. 
11 
Q7 (G – S) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
12 
Q7 (D – S) 
Short 
-- 
Input current= 0.34A to 0A. 
Fuse open instantly, no hazards. 
13 
T2 (1 – 3) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
14 
T2 (4 – 5) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
15 
T2 (9 – 10, 
11) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
16 
T2 (7 – 10, 
11) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
17 
CT1 (1 – 2) 
Short 
-- 
Input current= 0.34A 
Unit  operated  normally.  No  hazards, 
no damaged. 
18 
CT1 (3 – 4) 
Short 
-- 
Input current= 0.34A 
Unit  operated  normally.  No  hazards, 
no damaged. 
19 
DT1 (9 – 8) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
20 
DT1 (4 – 2) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
21 
DT1 (3 – 1) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
22 
T1 (6 – 10) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
23 
T1 (8 – 9) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
24 
T1 (5 – 4) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
Page 35 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
No. 
Component 
Fault 
dT (K) / Component 
Other results 
(include description and test duration) 
25 
T1 (3 – 4) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
26 
T1 (2 – 1) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit  shutdown  instantly.  No  hazards, 
no damaged. 
27 
U1 (5 – 2) 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit shutdown instantly and TVS 
damage. No hazards 
Repeated three times. 
28 
R20 
Short 
-- 
Input current= 0.34A to 0.054A. 
Unit shutdown instantly and U1 
damage. No hazards 
Repeated three times. 
29 
Speaker 
output 
Short 
T2 coil 
66.1 
Input current= 0.34A to 0.25A 
Unit operated normally. No 
damaged, no hazards. 
T2 core 
64.7 
T1 coil 
53.6 
T1 core 
51.9 
DT1 coil 
49.5 
DT1 core 
47.5 
CT1 coil 
63.4 
CT1 core 
62.9 
External metal 
cover 
31.3 
Ambient 
24.7 
30 
Speaker 
Maximum 
Power 
T2 coil 
67.6 
Input current= 0.34A to 0.054A 
Unit shutdown instantly. No hazards, 
no damaged. 
 
T2 core 
66.3 
T1 coil 
52.8 
T1 core 
50.9 
DT1 coil 
47.4 
DT1 core 
45.5 
CT1 coil 
63.2 
CT1 core 
62.8 
External metal 
cover 
23.7 
Ambient 
23.8 
31 
Speaker 
(1/3W) 
Maximum 
Power 
T2 coil 
78.1 
Input current= 0.34A to 0.53A  
Unit operated normally. No 
damaged, no hazards. 
 
T2 core 
77.1 
T1 coil 
60.3 
Page of 112