Page 20 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60384-1, 4.38 
category B or better  ................................................ : 
 
N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal  ........................................................................ : 
 
N/A 
14.3 
Inductors and windings  
See 14.3.1 through 14.3.5. 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
Complied. 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  ............................... : 
See Markings and 
Instructions 
 
Transformers and inductors separately approved  . : 
No 
N/A 
14.3.2 
General  
Complied with the applicable 
subclauses of 14.3.3 through 
14.3.5. 
 
Insulation material complies with clause 20.1.4  
Complied with 20.1.4. 
14.3.3 
Constructional requirements  
See below. 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13  
See appended table 13.1. 
14.3.3.2 
Transformers meet the constructional requirements 
Complied. 
14.3.4 
Separation between windings 
See below. 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) .............................. : 
Complied with 8.8. 
 
Coil formers and partition walls > 0,4 mm  
 
N/A 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met  
 
N/A 
14.3.4.3 
Separating transformers with at least basic insulation   
N/A 
14.3.5 
Insulation between HAZARDOUS LIVE parts and 
ACCESSIBLE parts 
See below. 
N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation)  
Complied with 8.8. 
 
Coil formers and partition walls > 0,4 mm  
Complied. 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal  
 
N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity  
 
N/A 
14.4 
High voltage components  
 
N/A 
Page 21 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
 
N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 
N/A 
14.5 
Protective devices  
See below 
 
Protective devices used within their ratings  
Complied. 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
See appended table 13.1. 
14.5.1.1 
a) Thermal cut-outs separately approved  
 
N/A 
 
b) Thermal cut-outs tested as part of the submission   
N/A 
14.5.1.2 
a) Thermal links separately approved  
 
N/A 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
See appended table 14. 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ... : 
See Markings and 
Instructions 
14.5.2.3 
Not possible to connect fuses in parallel  ................ : 
 
N/A 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ......... : 
 
N/A 
14.5.3 
PTC thermistors comply with IEC 60730-1:2007 
 
N/A 
 
PTC devices (15 W) category V-1 or better  
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked  
 
N/A 
14.6 
Switches  
See below. 
14.6.1 a) 
Separate testing to IEC 61058-1 including: 
- 10 000 operations 
- Normal pollution suitability 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
Certified sources of switch 
used that comply with the 
requirements and 
characteristics.  
See appended table 14 for 
details. 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage 
 > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage  
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1  
 
N/A 
Page 22 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
Switch controlling < 0.2A with open contact  voltage 
 > 35 V (peak)/24 V dc complying with  14.6.4 and  
V-0 in annex G, G.1.1  
 
N/A 
14.6.2 
Switch tested to 14.6.1 b) constructed to IEC 61058-
1 subclause 13.1 and has making/breaking  action 
independent of speed of actuation  
 
N/A 
14.6.3 
Switch tested to 14.6.1 b) compliant with IEC 61058-
1 subclause 16.2.2 d) and  m) not attaining 
excessive temperatures in use  
 
N/A 
14.6.4 
Switch tested to 14.6.1 b) has adequate dielectric 
strength  
 
N/A 
14.6.5 
Mains switch controlling mains socket outlets 
additional tests to IEC 61058-1  
 
N/A 
 
Socket outlet current marking correct  
 
N/A 
14.7 
Safety interlocks  
 
N/A 
 
Safety interlocks to 2.8 of IEC 60950-1 
 
N/A 
14.8 
Voltage setting devices and the like  
 
N/A 
 
Voltage setting device not likely to be changed 
accidentally  
 
N/A 
14.9 
Motors 
 
N/A 
14.9.1 
Endurance test on motors  
 
N/A 
 
Motor start test  
 
N/A 
 
Dielectric strength test  
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc.   
 
N/A 
14.9.3 
Protection against moving parts  
 
N/A 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet clause. B.8, B.9 and 
B.10 of IEC 60950-1, Annex B  
 
N/A 
14.10 
Batteries 
 
N/A 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases  
 
N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries  
 
N/A 
14.10.3 
Recharging currents and times within manufacturers 
limits  
 
N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits  
 
N/A 
14.10.4 
Battery mould stress relief  
 
N/A 
14.10.5 
Battery drop test  
 
N/A 
14.11 
Optocouplers  
Certified optical isolator. See 
appended table 14 for details. 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
N/A 
Page 23 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
b) Comply with IEC 60747-5-5:2007 
 
N/A 
 
Alternative to a) and b) optocoupler comply with 13.8   
N/A 
 
a) Comply with 13.6 (jointed insulation) and N.2.1  
 
N/A 
14.12 
Surge suppression varistors  
Certified photo-coupler. See 
appended table 14 for details. 
 
Comply with IEC 61051-2  
 
 
Not connected between mains and accessible parts 
except for earthed parts of permanently connected 
apparatus  
 
N/A 
 
Complies with the current pulse, fire hazard and 
thermal stress requirements of 14.12  
 
 
15 
Terminals 
15.1.1 
Mains plug, appliance inlet, interconnection couplers 
and mains socket-outlet meet the appropriate 
standard  
Approved power cord with plug 
provided. 
 
Overloading of plugs or appliance inlets prevented if 
the apparatus has mains socket outlets  
 
N/A 
 
Overloading of internal wiring prevented if the 
apparatus has mains socket outlets  
 
N/A 
15.1.2 
Connectors for antenna, earth, audio, video or  
data  
None of mismatch of 
connectors to AC mains 
occurred. 
N/A 
 
No risk of insertion in mains socket-outlets  
No such outlets. 
N/A 
 
No risk of insertion into audio- or video- outlets 
marked with the symbol of 5.2  
 
N/A 
15.1.3 
Output terminals of a.c. adaptors or similar devices 
not compatible with household mains socket-outlets  
 
N/A 
15.2 
Provision for protective earthing 
N/A 
 
Accessible conductive parts of Class I equipment 
reliably connected to earth terminal, within 
equipment  
 
N/A 
 
Protective earth conductors correctly coloured  
 
N/A 
 
Equipment with non-detachable mains cord provided 
with separate protective earth terminal near mains 
input  
 
N/A 
 
Protective earth terminal resistant to corrosion  
 
N/A 
 
Earth resistance  test: < 0,1 Ω at 25 A  ................... : 
 
N/A 
15.3 
Terminals for external flexible cords and for 
permanent connection to the mains supply 
See below. 
15.3.1 
Adequate terminals for connection of permanent 
wiring  
Not permanently connected 
equipment. 
N/A 
15.3.2 
Reliable connection of non-detachable cords  
See below. 