Page 54 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
openings completely, and for ventilation not 
exceeding 1 mm in width regardless of length. 
b) The following parts which would contribute 
negligible fuel to a fire: 
- small mechanical parts, the mass of which does 
not exceed 4 g, 
- such as mounting parts, gears, cams, belts and 
bearings; 
small electrical components, such as capacitors 
with a volume not exceeding 1750 mm
3
integrated circuits, transistors and optocoupler 
packages, if these components are mounted on 
material of flammability category V-1 or better 
according to AS/NZS 60695.11.10. 
NOTE - In considering how to minimize 
propagation of fire and what 'small parts' are, 
account should be taken of the cumulative effect 
of small parts adjacent to each other for the 
possible effect of propagating fire from one part 
to another. 
Compliance shall be checked by the tests of 
20.201.2.1, 20.201.2.2. and 20.201.2.3 
For the base material of PRINTED BOARDS, 
compliance shall be checked by the test of 
20.201.2.4.  
The tests shall be carried out on parts of non-
metallic material which have been removed from 
the apparatus. When the glow-wire test is carried 
out, they are placed in the same orientation as 
they would be in normal use. 
These tests are not carried out on internal wiring. 
20.201.2 Tests 
20.201.2.1 Testing of non-metallic parts 
Part of non-metallic material shall be subject to 
the glow-wire test of AS/NZS 60695.2.11 which 
shall be carried out at 550°C. 
Parts for which the glow-wire test cannot be 
carried out, such as those made of soft or foamy 
material, shall meet the requirements specified in 
ISO 9772 for category FH-3 material. The glow-
wire test shall not be carried out on parts of 
material classified at least FH-3 according to ISO 
9772 provided that the sample tested was not 
thicker than the relevant part.  
20.201.2.2 Testing of insulated parts 
Part of insulating material supporting 
POTENTIAL IGNITION SOURCES shall be 
subject to the glow-wire test of AS/NZS 
60695.2.11 which shall be carried out at 750°C. 
The test shall be also carried out on other parts of 
 
Page 55 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
insulating material which are within a distance of 
3 mm of the connection. 
NOTE - Contacts in components such as switch 
contacts are considered to be connections. 
For parts which withstand the glow-wire test but 
produce a flame, other parts above the 
connection within the envelope of a vertical 
cylinder having a diameter of 20 mm and a height 
of 50 mm shall be subjected to the needle flame 
test. However, parts shielded by a barrier which 
meets the needle-flame test need not be tested. 
The needle-flame test shalt be made in 
accordance with AS/NZS 60695.11.5 with the 
following modifications: 
Clause of 
AS/NZS 
60695.11.5 
Change 
9 Test 
Procedure 
 
9.2 
Applicatio
n of 
needle-
flame 
Replace the second sentence of 
the first paragraph with: 
The specimen shall be arranged 
so that the flame can be applied 
t o a vertical or horizontal edge 
as shown in the examples of 
figure 1. 
Add to the end of the first 
paragraph: 
If possible, the flame shall be 
applied at least 10 mm from a 
corner. 
Replace the second paragraph 
with: 
The duration of application of the 
test flame shalt be 30 ±1 s. 
9.3 
Number of 
specimens 
Replace with: 
The test shall be made on one 
specimen. If the specimen does 
not withstand the test, the test 
may be repeated on two further 
specimens, both of which shall 
then withstand the test 
11 
Evaluation 
of test 
results 
Replace with: 
The duration of burning (tb} shall 
not exceed 30 s. However, for 
printed circuit boards, it shall not 
exceed 15 s. 
The needle-flame test shall not be carried out on 
 
Page 56 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
parts of material classified as V-0 or V-1 
according to AS/NZS 60695.11.10 provided that 
the sample tested was not thicker than the 
relevant part. 
20.201.2.3 Testing by needle-flame test 
If parts, other than enclosures, do not withstand 
the glow wire tests of 20.201.2.2, by failure to 
extinguish within 30 s after the removal of the 
glow-wire tip, the needle-flame test detailed in 
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of 50 
mm or which are likely to be impinged upon by 
flame during the tests of 20.201.2.2. Parts 
shielded by a separate barrier that meets the 
needle-flame test shall not be tested. 
NOTE 1 - If the enclosure does not withstand the 
glow-wire test the appliance is considered to 
have failed to meet the requirements of Clause 
21.201 without the need for consequential 
testing. 
NOTE 2- If other parts do not withstand the glow-
wire test due to ignition of the tissue paper and if 
this indicates that burning or glowing particles 
can fall onto an external surface underneath the 
apparatus, the apparatus is considered to have 
failed to meet the requirements of Clause 21 .201 
without the need for consequential testing 
NOTE 3 - Parts likely to be impinged upon by the 
flame are considered to be those within the 
envelope of a vertical cylinder having a radius of 
10 mm and a height equal to the height of the 
flame , positioned above the point of the material 
supporting, in contact with, or in close proximity 
to, connections. 
20.201.2.4 Testing of printed boards 
The base material of PRINTED BOARDS shall be 
subject to the needle-flame test of Clause 
21.201.2.3. The flame shall be applied to the 
edge of the board where the heats ink effect is 
lowest when the board is positioned as in normal 
use. The flame shall not be applied to an edge 
consisting of broken perforations, unless the 
edge is less than 3 mm from a POTENTIAL 
IGNITION SOURCE. 
The test is not carried out if the 
-  PRINTED BOARD does not carry any 
potential ignition source; 
-  base material of PRINTED BOARDS, on 
which the available power at a connection 
exceeds 15 VA operating at a voltage 
exceeding 50 V and equal or less than 400 V 
 
Page 57 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
(peak) a.c. or d.c. under normal operating 
conditions, is of flammability category V-1 or 
better according to AS/NZS 60695.11.10, or 
the PRINTED BOARDS are protected by an 
enclosure meeting the flammability category 
V-0 according to AS/NZS 60695.11.10, or 
made of metal, having openings only for 
connecting wires which fill the openings 
completely; or 
-  base material of PRINTED BOARDS, on 
which the available power at a connection 
exceeds 15 VA operating at a voltage 
exceeding 400 V (peak) a.c. or d.c. under 
normal operating conditions, and base 
material of PRINTED BOARDS supporting 
spark gaps which provides protection against 
overvoltages, is of flammability category V-0 
according to AS/NZS 60695.11 .10 or the 
PRINTED BOARDS are contained in a metal 
enclosure, having openings only for 
connecting wires which fill the openings 
completely. 
Compliance shall be determined using the 
smallest thickness of the material. 
NOTE- Available power is the maximum power 
which can be drawn from the supplying circuit 
through a resistive load whose value is chosen to 
maximize the power for more than 2 min when 
the circuit supplied is disconnected. 
20.201.3 For open circuit voltages greater 
than 4 kV 
POTENTIAL IGNITION SOURCES with open 
circuit voltages exceeding 4 kV (peak) a.c. or d.c. 
under normal operating conditions shall be 
contained in a FIRE ENCLOSURE which shall 
comply with flammability category V-1 or better 
according to AS/NZS 60695.11.10. 
 
Page of 112