JBL SUB 250P (serv.man2) EMC - CB Certificate ▷ View online
Page 42 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
test probe B (IEC 61032)
9.1.1.2
Reference to test probes 18 and 19 of IEC 61032
are deleted
are deleted
P
10
Table 5, Note 1: With respect to mains voltages in
the range of 105-130 V (r.m.s.), the test voltages
are considered to be 1414 V peak for basic and
supplementary insulation and 2828 V peak for
reinforced insulation
the range of 105-130 V (r.m.s.), the test voltages
are considered to be 1414 V peak for basic and
supplementary insulation and 2828 V peak for
reinforced insulation
P
11
Component power supplies and their power
transformers complying with UL 1310, UL 1950
Third Edition, UL 60950, or UL 60950-1 are
considered to fulfill the clause
transformers complying with UL 1310, UL 1950
Third Edition, UL 60950, or UL 60950-1 are
considered to fulfill the clause
N/A
11.1
The permissible touch current for terminal contacts
has been increased to twice the value given in
9.1.1.1.
has been increased to twice the value given in
9.1.1.1.
N/A
11.2.1
Additional fuse testing is not required if the
temperature is limited by fuses
temperature is limited by fuses
N/A
12
Component power supply adaptors and their
enclosures complying with UL 1310, UL 1950
Third Edition, UL 60950, or UL 60950-1 are
considered to fulfill the clause.
enclosures complying with UL 1310, UL 1950
Third Edition, UL 60950, or UL 60950-1 are
considered to fulfill the clause.
N/A
12.1.3
Impact test uses the 50 mm steel sphere only
P
12.1.3
Table 6 - Impact test criteria detailing impact
location, impact energy and additional pass/fail
results applied according to UL 60065
location, impact energy and additional pass/fail
results applied according to UL 60065
P
12.1.4
As an alternative, any number from one to three
samples are permitted to be used in any
combination that results in a total of three drops
samples are permitted to be used in any
combination that results in a total of three drops
N/A
12.1.6
Handle strength test. When polymeric materials
are involved, testing is to be conducted before and
after the sub-clause 12.1.5 stress relief test.
are involved, testing is to be conducted before and
after the sub-clause 12.1.5 stress relief test.
N/A
12.8
Test for enclosures, barriers, components and
leads that rely on adhesive
leads that rely on adhesive
N/A
13
Component power supplies and their power
transformers complying with UL 1310, UL 1950
Third Edition, UL 60950, or UL 60950-1 are
considered to fulfill the clause.
transformers complying with UL 1310, UL 1950
Third Edition, UL 60950, or UL 60950-1 are
considered to fulfill the clause.
N/A
13.4
The material group is verified according to UL
746A
746A
N/A
13.4
Reference to the IEC 60112 PTI test is deleted
N/A
13.5.1
Reference to IEC 60249-2 is replaced by UL 796
N/A
13.5.2
Coated printed wiring boards comply with UL 746C
N/A
13.5.3
Multilayer printed boards comply with relevant
requirements in UL 60950-1
requirements in UL 60950-1
N/A
14
Annex Y and additional component requirements
applied according to UL 60065
applied according to UL 60065
P
Page 43 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
14.1
Component power supplies and their resistors
complying with UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfil
the clause
complying with UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfil
the clause
N/A
14.2
Component power supplies and their resistors
complying with UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfil
the clause
complying with UL 1310, UL 1950 Third Edition,
UL 60950, or UL 60950-1 are considered to fulfil
the clause
N/A
14.2.1
As an alternative, a component such as a
capacitor, a combination capacitor and resistor, or
a suppressor may comply with UL 1414.
capacitor, a combination capacitor and resistor, or
a suppressor may comply with UL 1414.
P
14.2.2
As an alternative, a capacitor, a combination
capacitor and resistor, or a varistor, or a
suppressor may comply with UL 1414.
capacitor and resistor, or a varistor, or a
suppressor may comply with UL 1414.
P
14.2.4
Components subjected to the requirements in
14.2.1 and 14.2.2 also comply with UL 1414
enclosure requirements
14.2.1 and 14.2.2 also comply with UL 1414
enclosure requirements
N/A
14.3
Component power supplies and their inductors
and windings complying with UL 1310, UL 1950
Third Edition, UL 60950, or UL 60950-1 are
considered to fulfill the clause
and windings complying with UL 1310, UL 1950
Third Edition, UL 60950, or UL 60950-1 are
considered to fulfill the clause
N/A
14.3.2
Planar transformers comply with the requirements
for multilayer printed boards
for multilayer printed boards
N/A
14.4
Planar transformers comply with the requirements
for multilayer printed boards
for multilayer printed boards
N/A
14.4.1
High voltage arcing test replaces the High voltage
transformers and multipliers test
transformers and multipliers test
N/A
14.4.2
Deleted
N/A
14.4.3
High voltage component part flame test
N/A
14.4.4
High voltage isolating component test
N/A
14.5.1.1
Thermal cut-outs comply with UL 873 or UL
60730-2-9
60730-2-9
N/A
14.5.1.2
Thermal links comply with UL 60691
N/A
14.5.1.3
Deleted
N/A
14.5.2.1
Fuse links comply with UL 248-14
P
14.5.2.2
Reference to IEC 60127 is deleted
N/A
14.5.2.2
Pre-arcing time/current characteristic and breaking
capacity marking requirements are deleted
capacity marking requirements are deleted
N/A
14.5.3
As an alternative, a PTC thermistor may comply
with requirements of UL 1434
with requirements of UL 1434
N/A
14.5.4
Reference to fuse-links is deleted
N/A
14.5.3A
Other protective devices directly connected to the
mains have adequate breaking capacity and
comply with UL 873, UL 1416, UL 1417 or UL
mains have adequate breaking capacity and
comply with UL 873, UL 1416, UL 1417 or UL
N/A
Page 44 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
2111
14.6.1
Switches and relays comply with UL 1054, UL
61058-1 or UL 508
61058-1 or UL 508
P
14.6.1
Mains switch or relay are rated for the total rated
current consumption of the apparatus
current consumption of the apparatus
N/A
14.6.1
Rating of a mains switch or relay in audio
apparatus intended for commercial use
apparatus intended for commercial use
N/A
14.6.2,
14.6.3,
14.6.4
14.6.3,
14.6.4
deleted.
N/A
14.6.5
A switch or relay that controls a mains socket-
outlet have a rating equal to the rated current
consumption of the apparatus plus the current
rating of the socket-outlet
outlet have a rating equal to the rated current
consumption of the apparatus plus the current
rating of the socket-outlet
N/A
14.6.6
Mains switches comply with (a), (b) or (c). The
contacts of a mains relay complies with (a), (b) or
(d). A switch that controls a mains receptacle
complies with (b) and a relay that controls a mains
receptacle complies with (b) or (d)
contacts of a mains relay complies with (a), (b) or
(d). A switch that controls a mains receptacle
complies with (b) and a relay that controls a mains
receptacle complies with (b) or (d)
N/A
14.6.6a
Switch or relay contacts have an rms current rating
equal to or greater than the peak inrush current of
the apparatus divided by 1.414
equal to or greater than the peak inrush current of
the apparatus divided by 1.414
N/A
14.6.6a
Switch or relay contacts have an rms current rating
equal to or greater than the peak inrush current of
the apparatus divided by 10, when:
equal to or greater than the peak inrush current of
the apparatus divided by 10, when:
- the rms current during normal operation
controlled by the switch is less than or equal to ½
the rms rating of the switch, and
controlled by the switch is less than or equal to ½
the rms rating of the switch, and
- the switch has double or multiple poles
controlling the mains current, either in series or
switching each mains line
controlling the mains current, either in series or
switching each mains line
N/A
14.6.6b
Switch or relay is TV rated
N/A
14.6.6c
Switch is located on the back of apparatus and is
not operable from a remote control
not operable from a remote control
N/A
14.6.6d
Relay is to be subjected to the Relay endurance
test
test
N/A
14.6.6.1
Peak inrush current test
N/A
14.6.6.2
Relay endurance test
N/A
14.6.7
Double pole switch controlling a.c. and d.c. circuits
N/A
14.7
The jointed test finger (figure 18) is used to
determine accessibility and operation of the
interlock
determine accessibility and operation of the
interlock
N/A
14.10.1
N/A
Page 45 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
14.10.1
Test requirements from UL 2054 are added for
special battery packs that are removable by the
user from the apparatus and may be carried
separately from the apparatus – Short circuit test,
Abnormal charging test, Forced-discharge test,
and 250-N steady force test.
special battery packs that are removable by the
user from the apparatus and may be carried
separately from the apparatus – Short circuit test,
Abnormal charging test, Forced-discharge test,
and 250-N steady force test.
N/A
14.10.1
Note: Consumer grade, non-rechargeable carbon-
zinc or alkaline batteries are not subjected to the
tests specified in 14.10.2 –14.10.5.
zinc or alkaline batteries are not subjected to the
tests specified in 14.10.2 –14.10.5.
N/A
14.10.5
As an alternative, one sample may be subjected to
three drops
three drops
N/A
14.10.6
Location of overcurrent protective device
N/A
14.10.6
As an alternative, the overcurrent protective device
in the apparatus battery-supply circuit is not
required if the apparatus is intended to be
connected to a vehicle power outlet using a UL
2089 vehicle battery adapter
in the apparatus battery-supply circuit is not
required if the apparatus is intended to be
connected to a vehicle power outlet using a UL
2089 vehicle battery adapter
N/A
14.11
As an alternative, the overcurrent protective device
in the apparatus battery-supply circuit is not
required if the apparatus is intended to be
connected to a vehicle power outlet using a UL
2089 vehicle battery adapter
in the apparatus battery-supply circuit is not
required if the apparatus is intended to be
connected to a vehicle power outlet using a UL
2089 vehicle battery adapter
N/A
14.11
As an alternative, the overcurrent protective device
in the apparatus battery-supply circuit is not
required if the apparatus is intended to be
connected to a vehicle power outlet using a UL
2089 vehicle battery adapter
in the apparatus battery-supply circuit is not
required if the apparatus is intended to be
connected to a vehicle power outlet using a UL
2089 vehicle battery adapter
N/A
14.11
Optocouplers bridging reinforced insulation comply
with requirements for double protection as
specified in UL 1577
with requirements for double protection as
specified in UL 1577
P
14.11
External clearances and creepage distances of
optocouplers comply with 13.1
optocouplers comply with 13.1
P
14.12
Reference to IEC 61051-2 replaced by UL 1449
P
14.12
Reference to IEC 60695-11-10 replaced by UL 94
P
14.12
All references to IEC 60151 are deleted
N/A
15.1.1
Attachment plug current rating (no less than 125%
of the current drawn under normal operating
conditions) and voltage rating
of the current drawn under normal operating
conditions) and voltage rating
P
15.1.1
Configuration and electrical rating of an
attachment plug for apparatus designed to be
used on more than one supply voltage by means
of a voltage selector
attachment plug for apparatus designed to be
used on more than one supply voltage by means
of a voltage selector
N/A
15.1.1
Polarized attachment plug
N/A
15.1.1
Wire gauge of conductors and internal wiring
connecting mains socket-outlets
connecting mains socket-outlets
N/A
15.1.3.1
Means of output connections on an audio amplifier
having an open-circuit audio output voltage not
having an open-circuit audio output voltage not
N/A