Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
limited to 120 V that is permanently connected to
the mains
the mains
15.1.3.1
Quick Connect Terminals:
a) Male tabs firmly mounted in place;
b) Mating female connectors provided with the
apparatus;
apparatus;
c) Strain Relief Test of Clause 16.5;
d) Installation instructions provided for assembly of
terminal to a conductor and strain relief
terminal to a conductor and strain relief
e) Terminals are appropriate for use with the size
and type of wire specified
and type of wire specified
P
15.1.3.2
Audio amplifiers having an audio output not limited
to 120 V that are connected to the mains by a
flexible cord
to 120 V that are connected to the mains by a
flexible cord
N/A
15.2
Protective earthing conductor termination
construction
construction
N/A
15.2
Cross-sectional area of the earthing conductor in a
supply cord or in an interconnecting cable
supply cord or in an interconnecting cable
N/A
15.2
Earthing conductors may have green or
green/yellow insulation
green/yellow insulation
N/A
15.3.5
Reference to IEC 60950 is replaced by Article 310
of the National Electrical Code, ANSI/NFPA 70
of the National Electrical Code, ANSI/NFPA 70
N/A
15.3.5
Table 15 - "AWG" replace mm
2
values
N/A
15.4
Component power supply adaptors complying with
UL 1310, UL 1950 Third Edition, UL 60950, or UL
60950-1 fulfill the clause
UL 1310, UL 1950 Third Edition, UL 60950, or UL
60950-1 fulfill the clause
N/A
15.4.2
NOTE – include references to UL 498 and
ANSI/NEMA WD6 for mains plug dimensions
ANSI/NEMA WD6 for mains plug dimensions
N/A
15.4.2.1
Construction of the mains plug blade assembly
complies with UL 1310
complies with UL 1310
N/A
15.4.2.1
Direct plug-in units designed for use by travelers
comply with UL 1310
comply with UL 1310
N/A
16.1
Reference in the first paragraph to “sheathed”
flexible cords is deleted
flexible cords is deleted
N/A
References to IEC 60227 and IEC 60245 are
deleted
deleted
N/A
Ampacity and VW-1 marking of mains supply
flexible cords
flexible cords
N/A
Table 17A - Cords for apparatus
N/A
Table 17A: Certain supply apparatus may be
provided with a supply cord having 0,5 m minimum
length
provided with a supply cord having 0,5 m minimum
length
N/A
16.2
Power supply cord earthing conductor size
N/A
Reference to IEC 60950, Table 3B is replaced by
N/A
Page 47 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
Article 400 of the National Electrical Code
Table 18 - Upper current limit in column 1
increased from 16 to 30 A and "AWG" wire sizes
used
increased from 16 to 30 A and "AWG" wire sizes
used
N/A
16.3
c) Flexible cords not complying with 16.1, used as
connection between the apparatus and other
apparatus are marked VW-1
connection between the apparatus and other
apparatus are marked VW-1
N/A
16.5
When polymeric materials are involved, strain and
twist testing is to be conducted before and after
the sub-clause 12.1.5 stress relief test.
twist testing is to be conducted before and after
the sub-clause 12.1.5 stress relief test.
N/A
17.8
Expanded to include all cart/stand parts supplied
by the manufacturer, such as casters and
brackets. Suitable assembly instructions are
required.
by the manufacturer, such as casters and
brackets. Suitable assembly instructions are
required.
N/A
17.8
Relevant fixing means are not required when
installation is to be done by a skilled person
installation is to be done by a skilled person
N/A
17.10
Termination of aluminum conductors used as
internal wiring
internal wiring
N/A
17.11
An accessory was investigated to determine that:
a) The accessory, and the combination of the
accessory and the apparatus presents no hazard
in the sense of this standard, and
accessory and the apparatus presents no hazard
in the sense of this standard, and
b) The accessory is provided with installation
instructions.
instructions.
N/A
17.11.1
Installation of an accessory by a skilled person:
a) The mechanical positioning is accomplished by
means of tools normally available or by means of
special tools provided as part of the installation kit,
means of tools normally available or by means of
special tools provided as part of the installation kit,
b) The electrical connections are made by using
existing terminals and connections in the
apparatus or the building wiring
existing terminals and connections in the
apparatus or the building wiring
N/A
18
Non-intrinsically protected picture tubes shall
comply with 18.1, 18.2.2 and 18.3. Intrinsically
protected picture tubes with a maximum face
dimension exceeding 7.5 cm shall comply with UL
61965.
comply with 18.1, 18.2.2 and 18.3. Intrinsically
protected picture tubes with a maximum face
dimension exceeding 7.5 cm shall comply with UL
61965.
N/A
Enclosure opening dimensions
N/A
18.1
All tubes are mounted such that the enclosure of
the apparatus protects the tube against the effects
of implosion.
the apparatus protects the tube against the effects
of implosion.
N/A
Reference to IEC 61965 replaced by UL 61965
N/A
19
The tests in 19.1, 19.2 and 19.3 do not cause the
apparatus to overturn.
apparatus to overturn.
N/A
The test in 19.2.1 does not cause the apparatus to
slide
slide
N/A
When polymeric materials are involved, testing is
N/A
Page 48 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
to be conducted before and after the sub-clause
12.1.5 stress relief test.
12.1.5 stress relief test.
19.1
References to an apparatus in combination with a
supplied cart or recommended stand are deleted
supplied cart or recommended stand are deleted
N/A
19.2
References to an apparatus in combination with a
supplied cart or recommended stand are deleted
supplied cart or recommended stand are deleted
N/A
19.2.1
Glass Slide test
N/A
19.3
Horizontal force stability test using Table 20A
values from UL 60065
values from UL 60065
N/A
19.5
Reference to the impact hammer in the first
compliance paragraph is deleted
compliance paragraph is deleted
N/A
19.6.
Includes Equipment rack mounting test
N/A
20.1a
Delete
N/A
20.1b
Exception for parts such as protection TV lenses,
loudspeaker parts, external accessories, and
fibrous materials
loudspeaker parts, external accessories, and
fibrous materials
N/A
Reference to IEC 60695-11-10 is replaced by UL
94
94
N/A
20.1.2
Sleeving, extruded tubing and insulation on wiring
are rated VW-1:
are rated VW-1:
a) wiring located in a circuit that is considered a
potential ignition source, or
potential ignition source, or
b) wiring not located in a circuit that is a potential
ignition source but is in contact with wiring located
in a circuit that is a potential ignition source
ignition source but is in contact with wiring located
in a circuit that is a potential ignition source
P
Tape in contact with parts of circuits that are
potential ignition sources is flame retardant
potential ignition sources is flame retardant
P
20.1.3
Printed wiring boards, on which the available
power as the connection exceeds 15 W or the
operating voltage exceeds 50 V a.c. or d.c under
normal operating conditions, is of flammability
category V-1 or better
power as the connection exceeds 15 W or the
operating voltage exceeds 50 V a.c. or d.c under
normal operating conditions, is of flammability
category V-1 or better
P
Reference to IEC 60695-11-10 replaced by UL 94
P
Exception for printed boards housed in metal
enclosures is deleted
enclosures is deleted
N/A
Option to use Clause G.1 of Annex G is deleted
N/A
20.1.4
Components and parts comply with the relevant
flammability category according to UL 94 as
specified in table 21
flammability category according to UL 94 as
specified in table 21
P
20.1.4
Component power supplies complying with UL
1310, UL 1950 Third Edition, UL 60950, or UL
60950-1 fulfill the clause
1310, UL 1950 Third Edition, UL 60950, or UL
60950-1 fulfill the clause
N/A
20.1.4
Table 21 - Flammability categories for components
and parts
and parts
N/A
Page 49 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
20.2.1
Fire enclosure required:
1) circuits and components where the available
power exceeds 15 W,
power exceeds 15 W,
2) inductors and windings conductively connected
to the mains, and
to the mains, and
3) high-voltage products.
P
20.2.1
The fire enclosure complies with the flammability
requirements of Table 22 according to UL 94 and
746C
requirements of Table 22 according to UL 94 and
746C
P
20.2.1
Reference to IEC 60695-11-10 or clause G.1 of
annex G replaced by UL 94 or UL 746C
annex G replaced by UL 94 or UL 746C
P
20.2.1
Table 22 - Flammability categories for fire
enclosures
enclosures
P
20.2.2
P
20.2.2
Compliance is checked by inspection and
measurement and using the articulated finger
probe, figure 18.
measurement and using the articulated finger
probe, figure 18.
P
20.2.3
Outer enclosures have a minimum flammability
rating of HB when an internal fire enclosure is
provided
rating of HB when an internal fire enclosure is
provided
N/A
A
Apparatus intended for outdoor use or for wet
locations has any of the following attributes:
locations has any of the following attributes:
a) provided with a means to be transportable,
b) has a mass less than 35 kg,
c) can be battery operated, or
d) associated literature states or implies such use
N/A
A
An apparatus as described in a), b), or c) above
that is marked as specified in 5.4.1 a) is not
intended for outdoor or wet location use
that is marked as specified in 5.4.1 a) is not
intended for outdoor or wet location use
N/A
A
Apparatus permanently installed outdoors is
considered to be for permanent outdoor use
considered to be for permanent outdoor use
N/A
A.5
Clauses A.5, A.5.1 and A.5.4.1 are deleted
N/A
A.9.1.1
Touch current test after the water spray test
described in A.11.1.1
described in A.11.1.1
N/A
A.10
Clauses A.10, A.10.2 and A.10.2.1-2 are deleted
N/A
A.11.1.1
Clauses A.10, A.10.2 and A.10.2.1-2 are deleted
N/A
A.16.1
Flexible cords are suitable for outdoor use
N/A
A.20.2.1
Enclosures for an apparatus intended for
permanent outdoor location comply with
requirements for Type 3 enclosures in UL 50
permanent outdoor location comply with
requirements for Type 3 enclosures in UL 50
N/A
B
IEC 62151 Clause 4 applies except for 4.1.2,
4.1.3, 4.2.1.1 and 4.2.1.2
4.1.3, 4.2.1.1 and 4.2.1.2
N/A
B
The requirements of 4.2.1.1 are replaced by the
N/A