Page 38 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
ATTACHMENT TO TEST REPORT IEC 60065 
 KOREA NATIONAL DIFFERENCES
 
Audio, video and similar electronic apparatus – Safety requirements
 
Differences according .................... : 
K 60065 
Attachment Form No. ..................... : 
 
Attachment Form Originator ......... : 
TUV Rheinland Taiwan 
Master Attachment Form ............... : 
IECEE CB Bulletin on 2012-05-31 
 
 
 
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
5.101 
Other Marking: Wording  
고고고고  or an 
information regulated in IEC Publication 417 giving 
high voltage warning to layman shall be marked, if 
an apparatus contains a part more than 600 volts. 
 
N/A 
15.1.1 
Plugs for the connection of the apparatus to the 
supply mains and socket outlets for providing 
mains power to other apparatus shall comply with 
the Korean requirement (KSC8300 and 8305) 
 
N/A 
31 
Radio frequency interference 
The apparatus shall comply with the relevant 
CISPR requirements (EMC=EMI+EMS) 
 
N/A 
 
 
Page 39 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
ATTACHMENT TO TEST REPORT IEC 60065 
 
USA NATIONAL DIFFERENCES
 
Audio, video and similar electronic apparatus – Safety requirements
 
Differences according .................... : 
UL 60065 
Attachment Form No. ..................... : 
 
Attachment Form Originator ......... : 
TUV Rheinland Taiwan 
Master Attachment Form ............... : 
IECEE CB Bulletin on 2013-03-06 
 
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
1.1.1 
Delete reference to Annex L: Electronic flash 
apparatus for photographic purposes. Replace this 
with reference to UL 122. 
 
1.1.1 
Mains connected apparatus intended for field 
installation complies with the National Electrical 
Code, ANSI, NFPA 70. 
 
1.1.3 
Requirements of apparatus intended for outdoor 
use comply with applicable clause of Annex A 
 
N/A 
1.1.5 
Some apparatus covered by these requirements 
may also be required to comply with applicable 
requirements in other appropriate standards : 
 
N/A 
1.1.6 
Apparatus with nonmetallic enclosures intended to 
be installed in air-handling spaces shall 
additionally comply with UL 2043 
 
N/A 
4.2.1 
The rated supply voltage for single phase 
apparatus is assumed to be 120V or 120/240V 
 
4.2.4 
a) Minimum audio output is not less than 0.5 W 
per channel unless the maximum audio output is 
less than 0.5 W per channel 
 
N/A 
4.2.4.1 
An apparatus with multiple modes of operation, 
multiple signal input sources, or both, is operated 
according to the manufacturer's instructions to 
produce the maximum power input 
 
Table 2 
Table 2 - External supply sources are assumed to 
be capable of delivering 30 A, unless otherwise 
specified (UL 60065 no-load voltage and internal 
resistance values) 
 
N/A 
4.3.4 
As an alternative, PTC thermistors may also 
comply with UL 1434. 
 
N/A 
Test for conductive labels secured in place by 
adhesive 
 
N/A 
5.1 
Component power supplies and adapters 
complying with UL 1310, UL 1950, UL 60950, or 
UL 60950-1 are considered to fulfill items "a" 
through "i" of this clause. 
 
N/A 
 
Page 40 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
5.1f 
Rated mains frequency marking on apparatus 
 
5.1j 
Date of Manufacture marking 
 
5.1k 
Factory origin identification marking 
 
N/A 
5.1l 
Combination of two graphical symbols and 
supplementary marking and/or single graphical 
symbol marking 
 
N/A 
5.1m 
Equipment rack marking for audio/video systems 
 
N/A 
5.1n 
Class I apparatus having touch current levels 
greater than 0.75 MIU and equal to or less than 
3.5 MIU must be marked with a high touch current 
marking. 
 
N/A 
5.1o 
Marking on apparatus having grille/ventilation 
areas of the top surface that are permitted to have 
higher temperature rises according to Note b of 
Table 3 
 
N/A 
5.1p 
Marking for apparatus intended to be installed in 
air-handling spaces 
 
N/A 
5.2c 
Output terminals are marked with voltage, 
frequency and current or power; output terminals 
installed or interconnected in the field must be 
marked with the class of wiring 
 
N/A 
5.2d 
Speaker terminals are marked "Class 1 Wiring", 
"Class 2 Wiring" or "Class 3 Wiring". 
 
N/A 
5.2d 
Operation manual explains risks and proper 
connecting and insulating techniques when 
connecting a speaker 
 
N/A 
5.3c 
An explanation and illustration of safety related 
graphical symbols used on the apparatus are 
included in the user instructions preceding any 
operating instructions 
 
5.4 
Important safety instructions are packed with each 
apparatus 
 
5.4.1 
Outdoor use marking for apparatus having no 
protection against exposure to water 
 
N/A 
5.4.1e 
Deleted 
 
N/A 
5.4.1e 
Reference to IEC 61695 is replaced by UL 61965 
 
N/A 
5.4.3 
When user operation and installation instructions 
contains instructions for use by skilled persons, the 
instructions are separate in format and preceded 
by a precautionary warning statement 
 
N/A 
6.1 
Compliance is checked in accordance with the 
requirements in the U.S. Code of Federal 
Regulations, Title 21, Chapter 1, Subchapter J, 
Sections 1010.2, 1010.3, and 1020.10 by 
measuring the radiation produced by the 
apparatus employing a production chassis 
 
N/A 
 
Page 41 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
6.2 
References to IEC 60825-1 are deleted 
 
N/A 
6.2 
Apparatus is classified and labeled according to 
the Code of Federal Regulations, Title 21, Chapter 
1, Subchapter J, Sections 1010.2, 1010.3, 1040.10 
and 1040.11. 
 
N/A 
6.2.2 
Deleted 
 
N/A 
Table 3: Delete reference to conditions h and i 
under Table item e for lithium batteries 
 
N/A 
Table 3: Temperature limits for various classes of 
insulation systems according to UL 60065 
 
N/A 
Table 3, Note a: Materials rated in accordance 
with UL 746B may be used within their rated 
temperature 
 
N/A 
Table 3, Note b: For grille/ventilation areas in the 
top surface directly above internal heatsinks, a 
temperature rise up to 65 K is allowed 
 
N/A 
7.2 
Applies to thermoplastic materials only. A material 
temperature rating can be accepted in lieu of the 
softening temperature. 
 
N/A 
7.2 
The softening test need not be performed on 
materials used in UL Listed or Recognized 
components 
 
N/A 
8.1 
Metal parts are corrosion resistant 
 
N/A 
8.9.1 
Sleeving, tape, tubing, and wire insulation comply 
with UL 224, UL 510, or UL 1441 
 
8.10 
Component power supplies and their internal 
insulation complying with UL 1310, UL 1950 Third 
Edition, UL 60950, or UL 60950-1 are considered 
to fulfill the clause 
 
N/A 
8.17 
As an option, winding wire insulation complies with 
the requirements in UL 2353 
 
N/A 
8.19.1 
An all-pole switch or circuit breaker is not required 
to have contact separation of 3 mm 
 
N/A 
8.23 
Printed wiring boards involved with the risk of 
electric shock comply with the requirements in UL 
796. 
 
N/A 
9.1.1.1a 
For audio signals of professional and commercial 
apparatus, 120 V r.m.s. 
 
N/A 
9.1.1.1a 
For audio signals other than professional and 
commercial apparatus, 71 V r.m.s. 
 
N/A 
9.1.1.1b 
Touch current carried out in accordance with UL 
101 with the measuring instrument described in 
Annex D shall not exceed 0.5 MIU. 
Delete Note 2. 
 
9.1.1.2 
UL articulated finger (figure 18) used instead of the   
Page of 112