Page 34 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
RATED CURRENT 
CONSUMPTION of the 
apparatus 
a
 
Nominal cross-
sectional area 
 
mm
2
 
up to and including 6 
Over 6 up to and including 
10 
Over 10 up to and including 
16 
0,75 
                           
1,5 
a
 The RATED CURRENT CONSUMPTION 
includes currents which can be drawn from 
the socket-outlets providing MAINS power for 
other apparatus. 
 
16.3 
Replacement: 
In item a), replace “IEC 60885-1” by “JIS C 3661-
1:1998”. 
 
N/A 
 
Replacement: 
In item b), replace “IEC 60227-2” by “JIS C 3662-
2 (corresponding to IEC 60227-2)”. 
 
N/A 
16.5 
Addition: 
Add “or CLASS 0I EQUIPMENT used a plug with 
an external earth wire” after the words, CLASS I 
EQUIPMENT. 
 
N/A 
20.1 
Replacement: 
In Note 3, replace each IEC 60065 and IEC 
60707 by “JIS C 6065” and “JIS C 0066:2001 
(IEC 60707). 
 
N/A 
Annex B 
Replacement: 
Replace normative by Informative. 
 
N/A 
Annex G 
Replacement: 
Replace IEC 60707 by JIS C 0066:2001 
Replace IEC 60695-2-2 by JIS C 60695-2-
2:2000. 
Replace IEC 60695-11-10 by JIS Z 2391:1999. 
 
N/A 
Annex N 
Addition: 
Add “- protective earthing lead wire, protective 
earthing contact of appliance inlet or external 
protective earthing terminal in case of Class 0I 
apparatus.” after the second dash of N.1.3. 
 
N/A 
 
Replacement: 
Replace the first sentence and two dashes of 
N.2.2, as follows: 
The continuity of the protective earthing 
conecction between  
- the ACCESSIBLE conductive parts, including 
TERMINALS regarded as ACCESSIBLE (see 
 
N/A 
 
Page 35 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
8.4), which should be connected to the 
PROTECTIVE EARTHING TERMINAL, and 
- the protective earthing contact of socket-outlets 
respectively, if provided to deliver power to other 
apparatus 
should be checked between 
- the protective earthing contact of the MAINS 
plug or appliance inlet, or the PROTECTIVE 
EARTHING TERMINAL in case of a 
PERMANENTLY CONNECTED APPARATUS, 
for CLASS I apparatus, and 
- the protective earthing lead wire, the protective 
earthing contact of appliance inlet, or external 
protective earthing terminal, for CLASS 0I 
apparatus. 
 
 
Page 36 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
ATTACHMENT TO TEST REPORT IEC 60065 
 
SWEDEN NATIONAL DIFFERENCES
 
Audio, video and similar electronic apparatus – Safety requirements
 
Differences according .................... : 
SS-EN 60065, 3rd EDITION 
Attachment Form No. ..................... : 
 
Attachment Form Originator ......... : 
TUV Rheinland Taiwan 
Master Attachment Form ............... : 
IECEE CB Bulletin on 2011-04-19 
 
 
 
 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
Annex B 
Replace NOTE 1 by 
In the CENELEC countries listed in IEC 62151, 
special national conditions apply. 
Add the following: 
All subclauses given below are subclauses of IEC 
62151:2000 (ref. Corrigendum 1 and 2 to IEC 
62151). 
Subclause 4.1.1 (Corrigendum 2):  
Add after the first paragraph: 
NOTE - In Sweden, CLASS I equipment which is 
intended for connection to the building installation 
via a non-industrial plug or a non-industrial 
appliance coupler, or both and in addition is 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that 
the equipment must be connected to an earthed 
mains socket -outlet. 
The marking text shall be as follows: 
"Apparaten skall anslutas till jordat uttag” 
Subclause 5.3.1 (Corrigendum 1): 
Add after the first test specifications paragraph: 
NOTE 1 In Finland, Norway and Sweden, there 
are additional requirements for the insulation. 
Renumber the existing note as note 2. 
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is added 
between the first and second paragraph (this text 
is identical to the text in EN 60950-1:2001): 
If this insulation is solid, including insulation 
forming part of a component, it shall at least 
consist of either 
- two layers of thin sheet material, each of which 
 
N/A 
 
Page 37 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
shall pass the electric strength test below, or 
- one layer having a distance through insulation 
of at least 0,4 mm, which shall pass the electric 
strength test below. 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES and CREEPAGE DISTANCES do 
not exist, if the component passes the electric 
strength test in the accordance with the 
compliance clause below and in addition: 
- passes the test and inspection criteria of 13.6 
with an electric strength test of 10.3 using the test 
voltage of 1,5 kV multiplied by 1,6, and 
- is subject to routine testing for electric strength 
during manufacturing, using a test voltage of 1,5 
kV (for performance of the test see N.2.1). 
It is permitted to bridge this insulation with a 
capacitor complying with IEC 60384-14:1993, 
subclass Y2. 
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the 
following conditions: 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
IEC 60384-14, which in addition to the Y3 testing, 
is tested with an Impulse test of 2.5kV defined in 
IEC 62151, subclause 6.2.1; 
- the additional testing shall be performed on all 
the test specimens as described in IEC 60384-
14; 
-  the Impulse test of 2.5kV is to be performed 
before the Endurance Test in IEC 60384-14 in 
the sequence of tests as described in IEC 60384-
14. 
Subclause 5.3.2 (Corrigendum 1): 
Add after the fourth dash: 
NOTE - In Sweden, exclusions are applicable for 
equipment which is intended for connection to the 
building installation wiring using screw terminals 
or other reliable means, and for equipment which 
is intended for connection to the building 
installation wiring via an industrial plug and 
socket -outlet or an appliance coupler, or both, 
complying with IEC 60309 or with a comparable 
national standard 
 