EMC - CB Certificate
Brand
Device
Audio
File
sub-250p-sm2.pdf
Date

JBL SUB 250P (serv.man2) EMC - CB Certificate ▷ View online

 
Page 30 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
4526-1:1999”. 
14.6.5 
Replacement: 
Replace “IEC 61058-1” by “ IEC 61058-1 or JIS C 
4526-1:1999”. 
 
N/A 
14.7 
Replacement: 
Replace “IEC 60950” by “JIS C 6950:2006”. 
 
N/A 
15.1.1 
Replacement: 
Replace the first and second paragraph by the 
following. 
Plugs and appliance couplers for the connection 
of the apparatus to the MAINS and socket-outlets 
and interconnection couplers for providing MAINS 
power to other apparatus shall comply with the 
relevant JIS standards for plugs, socket-outlets, 
appliance couplers or interconnection couplers. If 
there is no appropriate JIS standard, they shall 
comply with the relevant IEC standards. 
Appliance connectors, interconnection outlets 
and interconnection plug-connectors compiled 
with Appendix 3 of the Ministerial Ordinance on 
stipulating technical requirements for the 
Electrical Appliance and Material are accepted. In 
that case, if due to the shape the contact parts 
are connectable to those specified in standard 
sheets of IEC 60320-1, they shall comply with 
dimensions and ratings specified in the relevant 
standard sheets of IEC 60320-1. 
Examples of relevant specifications and 
standards: 
- Plugs / Socket-outlets: Appendix 4 of Article 1 of 
the Ministerial Ordinance on stipulating 
technical requirements for the Electrical 
Appliance. Article 2 (corresponding to IEC 
60884) of the Ordinance. 
-  Appliance couplers: Appendix 4 of Article 1 of 
the Ministerial Ordinance on stipulating 
technical requirements for the Electrical 
Appliance. Article 2 (corresponding to IEC 
60320-1) of the Ordinance. 
-  Appliance inlets: IEC 60320-1 
- Interconnection outlets: Appendix 4 of Article 1 
of the Ministerial Ordinance on stipulating 
technical requirements for the Electrical 
Appliance. IEC 60320-2-2.  
- Interconnection couplers: Appendix 4 of Article 
1 of the Ministerial Ordinance on stipulating 
technical requirements for the Electrical 
Appliance.  
Delete NOTE 1 and NOTE 2. 
 
N/A 
15.1.1 
Replacement: 
Replace the paragraph after NOTE 2 by the 
 
N/A 
 
Page 31 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
following. 
MAINS socket-outlets and interconnection 
couplers mounted on CLASS 0I and CLASS II 
apparatus shall not permit connection of CLASS I 
apparatus. 
15.1.1 
Replacement: 
Replace the paragraph before NOTE 3 by the 
following. 
MAINS socket-outlets and interconnection 
couplers mounted on CLASS I apparatus shall be 
provided with protective earthing contacts which 
are reliably connected to the PROTECTIVE 
EARTHING TERMINAL or contact of the 
apparatus. If not, it shall not permit connection of 
CLASS I apparatus. 
 
N/A 
 
Replacement: 
Replace NOTE 4 by the following. 
NOTE 4  Socket-outlets not allowing the 
connection of CLASS I apparatus can be 
designed, for instance, similar to IEC 60906-1, 
standard sheets 3-1 or 3-2, or according to IEC 
60320-2-2, standard sheets D or H. 
 
N/A 
15.1.2 
Deletion: 
Delete the following sentence in NOTE.  
An example of a connector not meeting the 
requirements of this sub clause is the so-called 
"banana" plug. 
 
N/A 
15.1.3 
Replacement: 
Replace the references, “IEC 60083 [1], IEC 
60320, IEC 60884, IEC 60906” by “JIS C 8282 
(corresponding to IEC 60884), JIS C 8303, IEC 
60320 and IEC 60906”. 
 
N/A 
15.2 
Addition: 
Add “and CLASS 0I EQUIPMENT” after the 
words, “CLASS I EQUIPMENT” 
 
N/A 
15.2 
Addition: 
Add the following paragraphs after the first 
paragraph. 
The external earth wire of plug with an external 
earth wire shall not be earthed by a clip. 
Rated voltage of plug with an protective external 
earth wire shall be less 150 Vac. 
 
N/A 
 
Deletion: 
Delete the following paragraph. 
In SUPPLY APPARATUS of CLASS I with non-
HAZARDOUS LIVE output voltage, output circuits 
shall not be connected to the protective earthing 
conductor. 
 
N/A 
 
Page 32 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
15.3.1 
Replacement: 
In the first paragraph, replace “IEC 60998-2-2” by 
“ IEC 60998-2-2 or JIS C 2814-2-2:2001”. 
 
N/A 
 
Replacement: 
In the first paragraph, replace “IEC 60999” by 
“IEC 60999-1”. 
 
N/A 
 
Replacement: 
In the third paragraph, replace “IEC 60335-1” by 
“JIS C 9335-1:2003 (corresponding to IEC 
60335-1)”. 
 
N/A 
15.3.3 
Replacement: 
Replace “ISO 261 or ISO 262” by “JIS B 0205-
2:2001 or JIS B 0205-3:2001”. 
 
N/A 
15.3.5 
Replacement: 
In the second paragraph, replace  
“IEC 60950” by “JIS C 6950:2006”. 
 
N/A 
15.3.5 
Replacement: 
Replace Table 15 by the following. 
RATED CURRENT 
CONSUMPTION of the 
apparatus 
a
 
Nominal cross-
sectional area 
mm
2
 
Up to and including 6 
                    
0.75 to 1 
Over 6 up to and including 
10 
1     to  1.5 
Over 10 up to and including 
16 
1.5  to  2.5 
 The RATED CURRENT CONSUMPTION 
includes currents which can be drawn from 
socket-outlets providing MAINS power for 
other apparatus. 
 
 
N/A 
15.3.9 
Addition: 
Add the following to the last of the first paragraph. 
This does not apply to CLASS 0I EQUIPMENT 
with a protectiive earthing terminal separately. 
 
N/A 
15.4.1 
Replacement: 
In NOTE 1, replace “IEC 60884-1” by “JIS C 8282 
(corresponding to IEC 60884-1)”. 
 
N/A 
 
Replacement: 
In NOTE 2, replace “IEC 60083 [1]” by “JIS C 
8303”. 
 
N/A 
15.4.2 
Replacement: 
In NOTE, replace “IEC 60083 [1]” by “JIS C 
 
N/A 
 
Page 33 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
8303:1993 [1]”. 
15.4.3 
Addition: 
Add the following NOTE to Table 17. 
NOTE  If mains plug is parallel blade, a pull force 
as given in  “Over 10 A up to and including 16 A, 
130/250 V” of Table 17 is applied. 
 
N/A 
16.1 
Addition: 
Add the following to the last of first paragraph. 
Or mains cords shall be of the sheathed type 
complying with Appendix 1 of Article 1 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance..  
Deletion: 
Delete NOTE 1. 
Replacement: 
Replace the second paragraph by the following. 
Compliance is checked by testing MAINS supply 
flexible cords in accordance with JIS C 3662 
(corresponding to IEC60227) or JIS C 3663 
(corresponding to IEC 60245), or Appendix 1 of 
Article 1 of the Ministerial Ordinance on 
stipulating technical requirements for the 
Electrical Appliance.   
 
N/A 
 
Replacement: 
In this sub-clause, replace “IEC 60227” by “JIS C 
3662 (corresponding to IEC 60227)”. 
In this sub-clause, replace “IEC 60245” by “JIS C 
3663 (corresponding to IEC 60245)”. 
 
N/A 
 
Addition: 
Add the following paragraph after the third 
paragraph. 
An external earth wire of Class 0I equipment shall 
be green/yellow, and the length of the external 
earth wire of plug with an external earth wire shall 
be equal or more than 10 cm from the plug. 
 
N/A 
16.2
 
Replacement: 
Replace the first paragraph by the following. 
Power supply cord conductors complied with JIS 
C 3662 (corresponding to IEC 60227) or JIS C 
3663 (corresponding to IEC 60245) shall have a 
nominal cross-sectional area not less than those 
shown in table 18. If power supply cord 
conductors comply with other standards, it shall 
comply with relevant wiring requirements.
 
 
N/A 
16.2 
Replacement: 
Replace Table 18 by the following. 
 
N/A 
Page of 112