JBL SUB 250P (serv.man2) EMC - CB Certificate ▷ View online

 
Page 18 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
by a candle flame is reduced. 
NOTE 1 An apparatus with a viewing screen is 
not regarded to be a television set if it is declared 
not to be so by the manufacturer. 
This requirement does not apply to the display 
screen of rear projection TV’s. 
NOTE 2 This exemption has been allowed 
because this technology is falling out of use and it 
is expected that within a few years it will no 
longer exist. This exemption will not be extended 
to other technologies. 
NOTE 3 The frame around the screen is not 
exempted from the requirements. 
Wood and WOOD-BASED MATERIAL with a 
thickness of at least 6 mm is considered to fulfil 
the V-1 requirement when applying CLC/TS 
62441. 
Compliance is checked according to CLC/TS 
62441. 
NOTE 4 The term vertical, as used in the first 
dash of clause 5.2 of CLC/TS 62441, does not 
mean a perfectly vertical position. It should be 
interpreted as any surface that can be touched by 
the flame of a candle of 150 mm height and 
20mm diameter while the candle is still touching 
the supporting surface. A typical candle used in 
the home is assumed to be 20 mm diameter. 
NOTE 5 It is expected that CLC/TS 62441 will in 
the future be replaced by a standard, at which 
time that standard will become applicable, subject 
to a vote by National Committees at the time. 
General 
13.3.1 
Delete note 4. 
14  
Delete note 4 and note 5. 
15.1.1 
Delete notes 1 and 2. 
15.2 
Delete note 2. 
16.1 
Delete note 1. 
16.2 
Delete the note. 
20 
Delete note 2. 
Annex B  
Replace note 1 by: In the CENELEC countries listed in IEC 62151, 
 
special national conditions apply. 
Annex G  
Delete the note. 
Annex J.2 
Delete the notes of Table J.1. 
Annex N  
Add after the introduction: For ROUTINE TEST reference is made 
to  
EN 50333. (Replaced by EN 50514) 
General 
(A2:2010) 
In IEC 60065:2001/A2 
Delete all the “country” notes according to the following list: 
5.3  
Note 
5.4.1  
Note 
20  
Note 
For special national conditions, see Annex ZB. 
Bibliography 
Additional EN standards. 
 
Page 19 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
 
 
 
ZA 
Normative references to international publications 
 
 
 
 
ZB 
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN) 
2.6.1 
 
DK: The following is added
Certain types of CLASS I apparatus, see 15.1.1, 
may be provided with a plug not establishing 
earthing continuity when inserted in Danish 
socket-outlets 
Justification: Heavy Current Regulations, Section 
107. 
 
N/A 
3.Z1 
(A2:2010) 
Denmark 
Add to the end of the subclause 
Due to many existing installations where the 
socket-outlets can be protected with fuses with 
higher rating than the rating of the socket-outlets 
the protection for pluggable equipment type A 
shall be an integral part of the equipment. 
Justification
In Denmark an existing 13 A socket outlet can be 
protected by a 20 A fuse. 
 
N/A 
5.3 
(A2:2010) 
Finland, Norway and Sweden 
To the end of the subclause the following is 
added
CLASS I 
apparatus which is intended for 
connection to the building installation wiring via a 
plug or an appliance coupler, or both and in 
addition is intended for connection to other 
apparatus or a network shall, if safety relies on 
connection to protective earth or if surge 
suppressors are connected between the network 
TERMINALS 
and 
ACCESSIBLE 
parts, have a marking 
stating that the apparatus must be connected to 
an earthed 
MAINS 
socket-outlet. 
The marking text in the applicable countries shall 
be as follows: 
In Finland: "Laite on liitettävä suojakoskettimilla 
varustettuun pistorasiaan" 
In Norway: “Apparatet må tilkoples jordet 
stikkontakt” 
In Sweden: “Apparaten skall anslutas till jordat 
uttag” 
 
N/A 
5.4 
(A11:2008) 
 
Finland, Norway and Sweden 
To the end of 5.4 the following is added
CLASS I apparatus which is intended for 
connection to the building installation wiring via a 
plug or an appliance coupler, or both and in 
 
N/A 
 
Page 20 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
addition is intended for connection to other 
apparatus or a network shall, if safety relies on 
connection to protective earth or if surge 
suppressors are connected between the network 
TERMINALS and ACCESSIBLE parts, have a 
marking stating that the apparatus must be 
connected to an MAINS socket-outlet with 
protective earth. 
The marking text in the applicable countries shall 
be as follows: 
In Finland: “Laite on liitettävä 
suojamaadoituskoskettimilla varustettuun 
pistorasiaan” 
In Norway: “Apparatet må tilkoples jordet 
stikkontakt” 
In Sweden: "Apparaten skall anslutas till jordat 
uttag" 
5.4.1 
(A11:2008) 
 
Norway and Sweden  
To the end of 5.4.1 (after the compliance 
statement) the following is added:  
The screen of the cable distribution system is 
normally not earthed at the entrance of the 
building and there is normally no equipotential 
bonding system within the building. Therefore the 
protective earthing of the building installation 
need to be isolated from the screen of a cable 
distribution system.  
It is however accepted to provide the insulation 
external to the equipment by an adapter or an 
interconnection cable with galvanic isolator, which 
may be provided by e.g. a retailer.  
The user manual shall then have the following or 
similar information in Norwegian and Swedish 
language respectively, depending on in what 
country the equipment is intended to be used in:  
“Equipment connected to the protective earthing 
of the building installation through the mains 
connection or through other equipment with a 
connection to protective earthing – and to a cable 
distribution system using coaxial cable, may in 
some circumstances create a fire hazard. 
Connection to a cable distribution system has 
therefore to be provided through a device 
providing electrical isolation below a certain 
frequency range (galvanic isolator, see EN 
60728-11)”  
NOTE In Norway, due to regulation for installations of cable 
distribution systems, and in Sweden, a galvanic isolator shall 
provide electrical insulation below 5 MHz. The insulation shall 
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz, 
for 1 min.  
Translation to Norwegian (the Swedish text will 
also be accepted in Norway):  
 
N/A 
 
Page 21 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
“Utstyr som er koplet til beskyttelsesjord via 
nettplugg og/eller via annet jordtilkoplet utstyr – 
og er tilkoplet et kabel-TV nett, kan forårsake 
brannfare. For å unngå dette skal det ved 
tilkopling av utstyret til kabel-TV nettet installeres 
en galvanisk isolator mellom utstyret og kabel-TV 
nettet.”  
Translation to Swedish:  
”Utrustning som är kopplad till skyddsjord via 
jordat vägguttag och/eller via annan utrustning 
och samtidigt är kopplad till kabel-TV nät kan i 
vissa fall medföra risk för brand.  
Főr att undvika detta skall vid anslutning av 
utrustningen till kabel-TV nät galvanisk isolator 
finnas mellan utrustningen och kabel-TV nätet.” 
13.3.1 
 
NO: To the second paragraph the following is 
added: 
In Norway, due to the IT power distribution 
system used, the a.c. MAINS supply voltage is 
considered to be equal to the line-to-line voltage, 
and will remain 230 V in case of a single earth 
fault. 
Justification: Based on a use in Norway of an IT 
power distribution system where the neutral is not 
provided. 
 
15.1.1 
(A11:2008) 
 
Denmark  
The text of the Danish SNC in EN 60065:2002 
has been modified as follows:  
To the first paragraph the following is added:  
In Denmark, supply cords of single-phase 
appliances having a rated current not exceeding 
13 A shall be provided with a plug according to 
the Heavy Current Regulations Section 107-2-D1.  
Appliances of CLASS I provided with socket-
outlets with earth contact or which are intended to 
be used in locations where protection against 
indirect contact is required according to the wiring 
rules shall be provided with a plug in accordance 
with the Heavy Current Regulations, Section 107-
2-D1 standard sheet DK 2-1a.  
To the second paragraph the following is added:  
Socket outlets intended for providing power to 
CLASS II apparatus with a rated current of 2,5 A 
shall be in accordance with the Heavy Current 
Regulation, Section 107-2-D1 standard sheet 
DKA 1-4a.  
Other current ratings socket outlets shall be in 
compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DKA 1-3a or 
DKA 1-3b.  
To the third paragraph the following is added:  
 
N/A 