JBL SUB 250P (serv.man2) EMC - CB Certificate ▷ View online
Page 18 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
by a candle flame is reduced.
NOTE 1 An apparatus with a viewing screen is
not regarded to be a television set if it is declared
not to be so by the manufacturer.
not regarded to be a television set if it is declared
not to be so by the manufacturer.
This requirement does not apply to the display
screen of rear projection TV’s.
screen of rear projection TV’s.
NOTE 2 This exemption has been allowed
because this technology is falling out of use and it
is expected that within a few years it will no
longer exist. This exemption will not be extended
to other technologies.
because this technology is falling out of use and it
is expected that within a few years it will no
longer exist. This exemption will not be extended
to other technologies.
NOTE 3 The frame around the screen is not
exempted from the requirements.
exempted from the requirements.
Wood and WOOD-BASED MATERIAL with a
thickness of at least 6 mm is considered to fulfil
the V-1 requirement when applying CLC/TS
62441.
thickness of at least 6 mm is considered to fulfil
the V-1 requirement when applying CLC/TS
62441.
Compliance is checked according to CLC/TS
62441.
62441.
NOTE 4 The term vertical, as used in the first
dash of clause 5.2 of CLC/TS 62441, does not
mean a perfectly vertical position. It should be
interpreted as any surface that can be touched by
the flame of a candle of 150 mm height and
20mm diameter while the candle is still touching
the supporting surface. A typical candle used in
the home is assumed to be 20 mm diameter.
dash of clause 5.2 of CLC/TS 62441, does not
mean a perfectly vertical position. It should be
interpreted as any surface that can be touched by
the flame of a candle of 150 mm height and
20mm diameter while the candle is still touching
the supporting surface. A typical candle used in
the home is assumed to be 20 mm diameter.
NOTE 5 It is expected that CLC/TS 62441 will in
the future be replaced by a standard, at which
time that standard will become applicable, subject
to a vote by National Committees at the time.
the future be replaced by a standard, at which
time that standard will become applicable, subject
to a vote by National Committees at the time.
General
13.3.1
Delete note 4.
14
Delete note 4 and note 5.
15.1.1
Delete notes 1 and 2.
15.2
Delete note 2.
16.1
Delete note 1.
16.2
Delete the note.
20
Delete note 2.
Annex B
Replace note 1 by: In the CENELEC countries listed in IEC 62151,
special national conditions apply.
Annex G
Delete the note.
Annex J.2
Delete the notes of Table J.1.
Annex N
Add after the introduction: For ROUTINE TEST reference is made
to
EN 50333. (Replaced by EN 50514)
P
General
(A2:2010)
In IEC 60065:2001/A2
Delete all the “country” notes according to the following list:
5.3
5.3
Note
5.4.1
Note
20
Note
For special national conditions, see Annex ZB.
P
Bibliography
Additional EN standards.
P
Page 19 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
ZA
Normative references to international publications
P
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
P
2.6.1
DK: The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish
socket-outlets
may be provided with a plug not establishing
earthing continuity when inserted in Danish
socket-outlets
Justification: Heavy Current Regulations, Section
107.
107.
N/A
3.Z1
(A2:2010)
Denmark
Add to the end of the subclause
Due to many existing installations where the
socket-outlets can be protected with fuses with
higher rating than the rating of the socket-outlets
the protection for pluggable equipment type A
shall be an integral part of the equipment.
socket-outlets can be protected with fuses with
higher rating than the rating of the socket-outlets
the protection for pluggable equipment type A
shall be an integral part of the equipment.
Justification:
In Denmark an existing 13 A socket outlet can be
protected by a 20 A fuse.
protected by a 20 A fuse.
N/A
5.3
(A2:2010)
Finland, Norway and Sweden
To the end of the subclause the following is
added:
added:
CLASS I
apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS
and
ACCESSIBLE
parts, have a marking
stating that the apparatus must be connected to
an earthed
an earthed
MAINS
socket-outlet.
The marking text in the applicable countries shall
be as follows:
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
varustettuun pistorasiaan"
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat
uttag”
uttag”
N/A
5.4
(A11:2008)
Finland, Norway and Sweden
To the end of 5.4 the following is added:
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
N/A
Page 20 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an MAINS socket-outlet with
protective earth.
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an MAINS socket-outlet with
protective earth.
The marking text in the applicable countries shall
be as follows:
be as follows:
In Finland: “Laite on liitettävä
suojamaadoituskoskettimilla varustettuun
pistorasiaan”
suojamaadoituskoskettimilla varustettuun
pistorasiaan”
In Norway: “Apparatet må tilkoples jordet
stikkontakt”
stikkontakt”
In Sweden: "Apparaten skall anslutas till jordat
uttag"
uttag"
5.4.1
(A11:2008)
Norway and Sweden
To the end of 5.4.1 (after the compliance
statement) the following is added:
statement) the following is added:
The screen of the cable distribution system is
normally not earthed at the entrance of the
building and there is normally no equipotential
bonding system within the building. Therefore the
protective earthing of the building installation
need to be isolated from the screen of a cable
distribution system.
normally not earthed at the entrance of the
building and there is normally no equipotential
bonding system within the building. Therefore the
protective earthing of the building installation
need to be isolated from the screen of a cable
distribution system.
It is however accepted to provide the insulation
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
external to the equipment by an adapter or an
interconnection cable with galvanic isolator, which
may be provided by e.g. a retailer.
The user manual shall then have the following or
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
similar information in Norwegian and Swedish
language respectively, depending on in what
country the equipment is intended to be used in:
“Equipment connected to the protective earthing
of the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device
providing electrical isolation below a certain
frequency range (galvanic isolator, see EN
60728-11)”
of the building installation through the mains
connection or through other equipment with a
connection to protective earthing – and to a cable
distribution system using coaxial cable, may in
some circumstances create a fire hazard.
Connection to a cable distribution system has
therefore to be provided through a device
providing electrical isolation below a certain
frequency range (galvanic isolator, see EN
60728-11)”
NOTE In Norway, due to regulation for installations of cable
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
distribution systems, and in Sweden, a galvanic isolator shall
provide electrical insulation below 5 MHz. The insulation shall
withstand a dielectric strength of 1,5 kV r.m.s., 50 Hz or 60 Hz,
for 1 min.
Translation to Norwegian (the Swedish text will
also be accepted in Norway):
also be accepted in Norway):
N/A
Page 21 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
“Utstyr som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr –
og er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres
en galvanisk isolator mellom utstyret og kabel-TV
nettet.”
nettplugg og/eller via annet jordtilkoplet utstyr –
og er tilkoplet et kabel-TV nett, kan forårsake
brannfare. For å unngå dette skal det ved
tilkopling av utstyret til kabel-TV nettet installeres
en galvanisk isolator mellom utstyret og kabel-TV
nettet.”
Translation to Swedish:
”Utrustning som är kopplad till skyddsjord via
jordat vägguttag och/eller via annan utrustning
och samtidigt är kopplad till kabel-TV nät kan i
vissa fall medföra risk för brand.
jordat vägguttag och/eller via annan utrustning
och samtidigt är kopplad till kabel-TV nät kan i
vissa fall medföra risk för brand.
Főr att undvika detta skall vid anslutning av
utrustningen till kabel-TV nät galvanisk isolator
finnas mellan utrustningen och kabel-TV nätet.”
utrustningen till kabel-TV nät galvanisk isolator
finnas mellan utrustningen och kabel-TV nätet.”
13.3.1
NO: To the second paragraph the following is
added:
added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
power distribution system where the neutral is not
provided.
P
15.1.1
(A11:2008)
Denmark
The text of the Danish SNC in EN 60065:2002
has been modified as follows:
has been modified as follows:
To the first paragraph the following is added:
In Denmark, supply cords of single-phase
appliances having a rated current not exceeding
13 A shall be provided with a plug according to
the Heavy Current Regulations Section 107-2-D1.
appliances having a rated current not exceeding
13 A shall be provided with a plug according to
the Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-
outlets with earth contact or which are intended to
be used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with the Heavy Current Regulations, Section 107-
2-D1 standard sheet DK 2-1a.
outlets with earth contact or which are intended to
be used in locations where protection against
indirect contact is required according to the wiring
rules shall be provided with a plug in accordance
with the Heavy Current Regulations, Section 107-
2-D1 standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet
DKA 1-4a.
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet
DKA 1-4a.
Other current ratings socket outlets shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or
DKA 1-3b.
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or
DKA 1-3b.
To the third paragraph the following is added:
N/A
Click on the first or last page to see other SUB 250P (serv.man2) service manuals if exist.