JBL SUB 250P (serv.man2) EMC - CB Certificate ▷ View online

 
Page 26 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
NOTE  Equipment often transported and used 
should not be Class I equipment nor Class 0I 
equipment. 
4.2.8 
Deletion: 
Delete this clause. 
 
N/A 
4.3.4, b) 
Replacement: 
Replace IEC 60730-1 by JIS C 9730-1 
(corresponding to IEC 60730-1). 
 
N/A 
4.3.12 
Deletion: 
Delete this clause. 
 
N/A 
4.3.13 
Replacement: 
Replace “250 V a.c.” by “the maximum of the 
variable range”. 
 
N/A 
5.4.2A 
Addition: 
For CLASS 0I EQUIPMENT, the following 
instruction shall be indicated where readily visible 
on the mains plug or the product: 
“WARNING:  Provide an earthing connection”  
Example in Japanese: 
 
 
Moreover, for CLASS 0I EQUIPMENT, the 
following instruction shall be indicated where 
readily visible on the product or written in the 
operating instructions: 
“WARNING:  Provide an earthing connection 
before the mains plug is connected to the mains. 
And, when disconnecting the earthing 
connection, be sure to disconnect after pulling out 
the mains plug from the mains.” 
Example in Japanese: 
 
 
N/A 
6.2 
Replacement: 
In NOTE 1, replace IEC 61040 [10] by JIS C 
6181:1995 [10]. 
 
N/A 
7.1.5 
 
Addition: 
Add the words, “without dimensions restrictions” 
after the figure, “65 K” in the first sentence of 
Condition “b” in Table 3 as follows. 
For parts not likely to be touched during intended 
 
N/A 
 
Page 27 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
use, temperature rises up to 65 K without 
dimensions restrictions are allowed under normal 
operating conditions. 
 
Addition: 
Add the following paragraph as 2
nd
 paragraph of 
Condition “d “in Table 3. 
For materials which are not listed in Table 3, 
temperature rises in the normal operating 
conditions are considered satisfactory if these 
materials comply with item 3 of detailed 
regulations, 1.(1),b, Appendix 4 in the Ministerial 
Ordinance on stipulating technical requirements 
for the Electrical Appliance and Material. 
Permissible temperature rise of “Supply cords 
and wiring insulation” is applicable only to the 
materials used in supply cords complying with 
JIS C 3662 (corresponding to IEC 60227) or JIS 
C 3663 (corresponding to IEC 60245). Materials 
used in other wiring shall comply with item 3 of 
detailed regulations, 1.(1).b, Appendix 4 in the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance and 
Material. 
 
N/A 
 
Addition: 
In the first paragraph of Condition “f” of Table 3, 
add ”JIS K 7206:1999 or” before the reference, 
ISO 306. 
 
N/A 
 
Addition: 
In Condition “f,” 1) of Table 3,  add ”JIS K 
7206:1999 or” before the reference, ISO 306. 
 
N/A 
7.2 
Addition: 
In NOTE 2, add ”or JIS standard (identical to or 
modified IEC)” after the word, IEC standard. 
 
N/A 
8.5 
Addition: 
In the first paragraph, add “and Class 0I 
Equipment” after the words, Class I Equipment. 
 
N/A 
8.5 
Addition: 
In the six paragraph (before NOTE 3), add the 
following to the end of the first sentence. 
CLASS 0I EQUIPMENT shall be provided with a 
protective earthing terminal at any point outside 
the apparatus where easily visible or a protective 
external earth wire from mains plug. 
 
N/A 
8.11 
Addition: 
In NOTE 2, c), add “or JIS C 2107, JIS C 2336, 
JIS C 2338” after the reference, IEC 60454. 
 
N/A 
9.1.1.1 
Addition: 
In the last paragraph, add the following sentence 
 
N/A 
 
Page 28 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
after the first sentence. 
For CLASS 0I EQUIPMENT, the r.m.s. TOUCH-
CURRENT to earth shall not be more than 1.0 
mA. 
10 
Replacement: 
In NOTE, replace “IEC 60664-1 and IEC 60664-4 
[9]” by “JIS C 0664:2003 and IEC/TR3 60664-4 
[8]” 
 
N/A 
10.1 
Addition: 
Add “CLASS 0I EQUIPMENT and” to the head of 
the first paragraph. 
 
N/A 
10.3.2 
Addition: 
In Table 5, add the following values to the sub-
table of NOTE. 
Operating Voltage 
(peak) 
Test voltage 
(peak) 
Curve A  Curve B 
142 V 
1 414 V  2 828 V 
 
 
N/A 
11.2.1 
Addition: 
Add the following after the original NOTE. 
NOTE 2  Fuses except for the ones according to 
IEC 60127 shall be tested in consideration of the 
characteristic. 
 
N/A 
11.2.3 
Addition: 
Add “and CLASS 0I” after the words, CLASS I. 
 
N/A 
13.4 
Replacement: 
In NOTE 2 of Table 11, replace “IEC 60664-1” by 
“JIS C 0664:2003” (corresponding to IEC 60664-
1). 
 
N/A 
14.3.3.2 
Addition: 
In the second sentence of the first paragraph, 
add “or JIS C 2107, JIS C 2336 and JIS C 2338” 
after the reference, IEC 60454. 
 
N/A 
14.5.1.1 
Addition: 
In item a), add “JIS C 9730 series or” before the 
reference, IEC 60730 series. 
 
N/A 
14.5.1.2 
Replacement: 
In the first sentence of item a), replace IEC 60691 
by “IEC 60691 or JIS C 6691:2003 or Appendix 3 
of the Ministerial Ordinance on stipulating 
technical requirements for the Electrical 
Appliance and Material”. 
 
N/A 
 
Replacement: 
After  the  second  sentence  of  item  a),  replace 
“IEC 60691” by “JIS C 6691:2003 or IEC 60691”. 
 
N/A 
 
Page 29 of 57 
Report No.: 11034065 001 
 
IEC 60065 ATTACHMENT 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
14.5.2.1 
Replacement: 
Replace the first and the second sentence as 
follows: 
Fuse-links, DIRECTLY CONNECTED TO THE 
MAINS, used in order to prevent the apparatus 
from becoming unsafe within the sense of this 
standard shall comply with 
- the relevant part of IEC 60127 or JIS C 6575, 
unless they have a rated current outside the 
range specified in that standard. In the latter 
case, they shall comply with the relevant part of 
IEC 60127 or JIS C 6575 as far as applicable, or 
- Appendix 3 of the Ministerial Ordinance on 
stipulating technical requirements for the 
Electrical Appliance and Material (limited to 
Fuses with the rated current of 1 A or more). 
 
N/A 
14.5.2.2 
Addition: 
Add the following sentence before the last 
paragraph. 
For fuses according to Appendix 3 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance and 
Material, all that needs to be marked is the rated 
current. 
 
N/A 
14.5.3 
Replacement: 
Replace “IEC 60730-1” by “JIS C 9730-1” 
(corresponding to IEC 60730-1). 
 
N/A 
14.5.4 
Replacement: 
Replace “IEC 60127” by “IEC 60127 or JIS C 
6575 ”. 
 
N/A 
14.6.1 
Addition: 
Add the following paragraph after NOTE. 
The following manually operated mechanical 
switches shall meet the requirements specified in 
item a) or b) below. 
-  the controlling current exceeds 0.2 A r.m.s a.c. 
or d.c. 
-  the voltage across the open switch contacts 
exceeds 35 Vpeak ac or 24 Vdc.   
 
N/A 
14.6.1 
Replacement: 
In item a), replace “IEC 61058-1” by “IEC 61058-
1 or JIS C 4526-1:1999”. 
 
N/A 
14.6.2 
Replacement: 
Replace “IEC 61058-1” by “IEC 61058-1 or JIS C 
4526-1:1999”. 
 
N/A 
14.6.3 
Replacement: 
Replace “IEC 61058-1” by “ IEC 61058-1 or JIS C 
 
N/A 
Page of 112