JBL SUB 250P (serv.man2) EMC - CB Certificate ▷ View online
Page 26 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
NOTE Equipment often transported and used
should not be Class I equipment nor Class 0I
equipment.
should not be Class I equipment nor Class 0I
equipment.
4.2.8
Deletion:
Delete this clause.
N/A
4.3.4, b)
Replacement:
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
(corresponding to IEC 60730-1).
N/A
4.3.12
Deletion:
Delete this clause.
N/A
4.3.13
Replacement:
Replace “250 V a.c.” by “the maximum of the
variable range”.
variable range”.
N/A
5.4.2A
Addition:
For CLASS 0I EQUIPMENT, the following
instruction shall be indicated where readily visible
on the mains plug or the product:
instruction shall be indicated where readily visible
on the mains plug or the product:
“WARNING: Provide an earthing connection”
Example in Japanese:
Moreover, for CLASS 0I EQUIPMENT, the
following instruction shall be indicated where
readily visible on the product or written in the
operating instructions:
following instruction shall be indicated where
readily visible on the product or written in the
operating instructions:
“WARNING: Provide an earthing connection
before the mains plug is connected to the mains.
And, when disconnecting the earthing
connection, be sure to disconnect after pulling out
the mains plug from the mains.”
before the mains plug is connected to the mains.
And, when disconnecting the earthing
connection, be sure to disconnect after pulling out
the mains plug from the mains.”
Example in Japanese:
N/A
6.2
Replacement:
In NOTE 1, replace IEC 61040 [10] by JIS C
6181:1995 [10].
6181:1995 [10].
N/A
7.1.5
Addition:
Add the words, “without dimensions restrictions”
after the figure, “65 K” in the first sentence of
Condition “b” in Table 3 as follows.
after the figure, “65 K” in the first sentence of
Condition “b” in Table 3 as follows.
For parts not likely to be touched during intended
N/A
Page 27 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
use, temperature rises up to 65 K without
dimensions restrictions are allowed under normal
operating conditions.
dimensions restrictions are allowed under normal
operating conditions.
Addition:
Add the following paragraph as 2
nd
paragraph of
Condition “d “in Table 3.
For materials which are not listed in Table 3,
temperature rises in the normal operating
conditions are considered satisfactory if these
materials comply with item 3 of detailed
regulations, 1.(1),b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements
for the Electrical Appliance and Material.
Permissible temperature rise of “Supply cords
and wiring insulation” is applicable only to the
materials used in supply cords complying with
JIS C 3662 (corresponding to IEC 60227) or JIS
C 3663 (corresponding to IEC 60245). Materials
used in other wiring shall comply with item 3 of
detailed regulations, 1.(1).b, Appendix 4 in the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material.
temperature rises in the normal operating
conditions are considered satisfactory if these
materials comply with item 3 of detailed
regulations, 1.(1),b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements
for the Electrical Appliance and Material.
Permissible temperature rise of “Supply cords
and wiring insulation” is applicable only to the
materials used in supply cords complying with
JIS C 3662 (corresponding to IEC 60227) or JIS
C 3663 (corresponding to IEC 60245). Materials
used in other wiring shall comply with item 3 of
detailed regulations, 1.(1).b, Appendix 4 in the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material.
N/A
Addition:
In the first paragraph of Condition “f” of Table 3,
add ”JIS K 7206:1999 or” before the reference,
ISO 306.
add ”JIS K 7206:1999 or” before the reference,
ISO 306.
N/A
Addition:
In Condition “f,” 1) of Table 3, add ”JIS K
7206:1999 or” before the reference, ISO 306.
7206:1999 or” before the reference, ISO 306.
N/A
7.2
Addition:
In NOTE 2, add ”or JIS standard (identical to or
modified IEC)” after the word, IEC standard.
modified IEC)” after the word, IEC standard.
N/A
8.5
Addition:
In the first paragraph, add “and Class 0I
Equipment” after the words, Class I Equipment.
Equipment” after the words, Class I Equipment.
N/A
8.5
Addition:
In the six paragraph (before NOTE 3), add the
following to the end of the first sentence.
following to the end of the first sentence.
CLASS 0I EQUIPMENT shall be provided with a
protective earthing terminal at any point outside
the apparatus where easily visible or a protective
external earth wire from mains plug.
protective earthing terminal at any point outside
the apparatus where easily visible or a protective
external earth wire from mains plug.
N/A
8.11
Addition:
In NOTE 2, c), add “or JIS C 2107, JIS C 2336,
JIS C 2338” after the reference, IEC 60454.
JIS C 2338” after the reference, IEC 60454.
N/A
9.1.1.1
Addition:
In the last paragraph, add the following sentence
N/A
Page 28 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
after the first sentence.
For CLASS 0I EQUIPMENT, the r.m.s. TOUCH-
CURRENT to earth shall not be more than 1.0
mA.
CURRENT to earth shall not be more than 1.0
mA.
10
Replacement:
In NOTE, replace “IEC 60664-1 and IEC 60664-4
[9]” by “JIS C 0664:2003 and IEC/TR3 60664-4
[8]”
[9]” by “JIS C 0664:2003 and IEC/TR3 60664-4
[8]”
N/A
10.1
Addition:
Add “CLASS 0I EQUIPMENT and” to the head of
the first paragraph.
the first paragraph.
N/A
10.3.2
Addition:
In Table 5, add the following values to the sub-
table of NOTE.
table of NOTE.
Operating Voltage U
(peak)
(peak)
Test voltage
(peak)
(peak)
Curve A Curve B
142 V
1 414 V 2 828 V
N/A
11.2.1
Addition:
Add the following after the original NOTE.
NOTE 2 Fuses except for the ones according to
IEC 60127 shall be tested in consideration of the
characteristic.
IEC 60127 shall be tested in consideration of the
characteristic.
N/A
11.2.3
Addition:
Add “and CLASS 0I” after the words, CLASS I.
N/A
13.4
Replacement:
In NOTE 2 of Table 11, replace “IEC 60664-1” by
“JIS C 0664:2003” (corresponding to IEC 60664-
1).
“JIS C 0664:2003” (corresponding to IEC 60664-
1).
N/A
14.3.3.2
Addition:
In the second sentence of the first paragraph,
add “or JIS C 2107, JIS C 2336 and JIS C 2338”
after the reference, IEC 60454.
add “or JIS C 2107, JIS C 2336 and JIS C 2338”
after the reference, IEC 60454.
N/A
14.5.1.1
Addition:
In item a), add “JIS C 9730 series or” before the
reference, IEC 60730 series.
reference, IEC 60730 series.
N/A
14.5.1.2
Replacement:
In the first sentence of item a), replace IEC 60691
by “IEC 60691 or JIS C 6691:2003 or Appendix 3
of the Ministerial Ordinance on stipulating
technical requirements for the Electrical
Appliance and Material”.
by “IEC 60691 or JIS C 6691:2003 or Appendix 3
of the Ministerial Ordinance on stipulating
technical requirements for the Electrical
Appliance and Material”.
N/A
Replacement:
After the second sentence of item a), replace
“IEC 60691” by “JIS C 6691:2003 or IEC 60691”.
“IEC 60691” by “JIS C 6691:2003 or IEC 60691”.
N/A
Page 29 of 57
Report No.: 11034065 001
IEC 60065 ATTACHMENT
Clause
Requirement + Test
Result - Remark
Verdict
14.5.2.1
Replacement:
Replace the first and the second sentence as
follows:
follows:
Fuse-links, DIRECTLY CONNECTED TO THE
MAINS, used in order to prevent the apparatus
from becoming unsafe within the sense of this
standard shall comply with
MAINS, used in order to prevent the apparatus
from becoming unsafe within the sense of this
standard shall comply with
- the relevant part of IEC 60127 or JIS C 6575,
unless they have a rated current outside the
range specified in that standard. In the latter
case, they shall comply with the relevant part of
IEC 60127 or JIS C 6575 as far as applicable, or
range specified in that standard. In the latter
case, they shall comply with the relevant part of
IEC 60127 or JIS C 6575 as far as applicable, or
- Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the
Electrical Appliance and Material (limited to
Fuses with the rated current of 1 A or more).
stipulating technical requirements for the
Electrical Appliance and Material (limited to
Fuses with the rated current of 1 A or more).
N/A
14.5.2.2
Addition:
Add the following sentence before the last
paragraph.
paragraph.
For fuses according to Appendix 3 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, all that needs to be marked is the rated
current.
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, all that needs to be marked is the rated
current.
N/A
14.5.3
Replacement:
Replace “IEC 60730-1” by “JIS C 9730-1”
(corresponding to IEC 60730-1).
(corresponding to IEC 60730-1).
N/A
14.5.4
Replacement:
Replace “IEC 60127” by “IEC 60127 or JIS C
6575 ”.
6575 ”.
N/A
14.6.1
Addition:
Add the following paragraph after NOTE.
The following manually operated mechanical
switches shall meet the requirements specified in
item a) or b) below.
switches shall meet the requirements specified in
item a) or b) below.
- the controlling current exceeds 0.2 A r.m.s a.c.
or d.c.
- the voltage across the open switch contacts
exceeds 35 Vpeak ac or 24 Vdc.
N/A
14.6.1
Replacement:
In item a), replace “IEC 61058-1” by “IEC 61058-
1 or JIS C 4526-1:1999”.
1 or JIS C 4526-1:1999”.
N/A
14.6.2
Replacement:
Replace “IEC 61058-1” by “IEC 61058-1 or JIS C
4526-1:1999”.
4526-1:1999”.
N/A
14.6.3
Replacement:
Replace “IEC 61058-1” by “ IEC 61058-1 or JIS C
N/A