JBL SUB 250P (serv.man2) EMC - CB Certificate ▷ View online
Page 36 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
No.
Component
Fault
dT (K) / Component
Other results
(include description and test duration)
(include description and test duration)
T1 core
58.8
DT1 coil
56.8
DT1 core
54.7
CT1 coil
74.7
CT1 core
74.2
External metal
cover
cover
29.2
Ambient
24.0
32
T1 (5 – 4)
(after D1)
Overload
T2 coil
61.7
Input current= 0.34A to 0.51A to
0.054A
When transformer overload to 1.6A,
then unit shutdown instantly. No
hazards.
0.054A
When transformer overload to 1.6A,
then unit shutdown instantly. No
hazards.
T2 core
61.4
T1 coil
88.2
T1 core
77
DT1 coil
49.7
DT1 core
47.1
CT1 coil
66.3
CT1 core
65.2
External metal
cover
cover
22.2
Ambient
27.8
33
T1 (3 – 4)
(Before D9)
Overload
T2 coil
65.6
Input current= 0.34A to 0.48A to
0.054A
When transformer overload to 2A,
then unit shutdown instantly. No
hazards.
0.054A
When transformer overload to 2A,
then unit shutdown instantly. No
hazards.
T2 core
65.4
T1 coil
104.4
T1 core
91.6
DT1 coil
53.6
DT1 core
50.9
CT1 coil
69.7
CT1 core
69.1
External metal
cover
cover
25.7
Ambient
25.2
34
T1 (2 – 1)
(after D4)
Overload
T2 coil
69.5
Input current= 0.34A to 0.51A to
0.054A
When transformer overload to 0.6A ,
10 minutes then unit shutdown, no
hazards.
0.054A
When transformer overload to 0.6A ,
10 minutes then unit shutdown, no
hazards.
T2 core
67.6
T1 coil
92.3
T1 core
79
DT1 coil
49.1
DT1 core
47.1
Page 37 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
No.
Component
Fault
dT (K) / Component
Other results
(include description and test duration)
(include description and test duration)
CT1 coil
64.4
CT1 core
64.1
External metal
cover
cover
24.5
Ambient
24.3
35
T2 (9 – 10,
11) (after D8)
Overload
T2 coil
108.4
Input current= 0.34A to 1.4A to
0.054A
When transformer overload to 2.4A ,
unit into after 79 minutes, then unit
shutdown. No hazards.
0.054A
When transformer overload to 2.4A ,
unit into after 79 minutes, then unit
shutdown. No hazards.
T2 core
100.3
T1 coil
78.7
T1 core
78.6
DT1 coil
81.3
DT1 core
78.8
CT1 coil
107.3
CT1 core
105.7
External metal
cover
cover
34.1
Ambient
24.7
Model SUB 250P/120 (input: 132Vac)
36
BR1
Short
--
Input current= 0.68A to 0A.
Fuse open instantly. No hazards.
Fuse open instantly. No hazards.
73
C1
Short
--
Input current= 0.68A to 0A.
Fuse open instantly. No hazards.
Fuse open instantly. No hazards.
38
U2 (1 – 2)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
39
U2 (3 – 4)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
40
U2 pin 1
Open
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
41
U2 pin 3
Open
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
42
Q6 (G – D)
Short
--
Input current= 0.68A to 0A.
Fuse open instantly. No hazards.
Fuse open instantly. No hazards.
43
Q6 (G – S)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
44
Q6 (D – S)
Short
--
Input current= 0.68A to 0A.
Fuse open instantly, no hazards.
Fuse open instantly, no hazards.
Page 38 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
No.
Component
Fault
dT (K) / Component
Other results
(include description and test duration)
(include description and test duration)
45
Q7 (G – D)
Short
--
Input current= 0.68A to 0A.
Fuse open instantly, no hazards.
Fuse open instantly, no hazards.
46
Q7 (G – S)
Short
--
Input current= 0.6A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
47
Q7 (D – S)
Short
--
Input current= 0.68A to 0A.
Fuse open instantly, no hazards.
Fuse open instantly, no hazards.
48
T2 (1 – 3)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
49
T2 (4 – 5)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
50
T2 (9 – 10,
11)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
51
T2 (7 – 10,
11)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
52
CT1 (1 – 2)
Short
--
Input current= 0.68A
Unit operated normally. No hazards,
no damaged.
Unit operated normally. No hazards,
no damaged.
53
CT1 (3 – 4)
Short
--
Input current= 0.68A
Unit operated normally. No hazards,
no damaged.
Unit operated normally. No hazards,
no damaged.
54
DT1 (9 – 8)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
55
DT1 (4 – 2)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
56
DT1 (3 – 1)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
57
T1 (6 – 10)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
58
T1 (8 – 9)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
59
T1 (5 – 4)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
60
T1 (3 – 4)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
Page 39 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
No.
Component
Fault
dT (K) / Component
Other results
(include description and test duration)
(include description and test duration)
61
T1 (2 – 1)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly. No hazards,
no damaged.
Unit shutdown instantly. No hazards,
no damaged.
62
U1 (5 – 2)
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly and TVS
damage. No hazards
Repeated three times.
Unit shutdown instantly and TVS
damage. No hazards
Repeated three times.
63
R20
Short
--
Input current= 0.68A to 0.03A.
Unit shutdown instantly and U1
damage. No hazards
Repeated three times.
Unit shutdown instantly and U1
damage. No hazards
Repeated three times.
64
Speaker
output
Short
T2 coil
60.5
Input current= 0.68A to 0.42A
Unit operated normally. No
damaged, no hazards.
Unit operated normally. No
damaged, no hazards.
T2 core
57.2
T1 coil
52.4
T1 core
50.7
DT1 coil
48.9
DT1 core
47.2
CT1 coil
65.2
CT1 core
65.1
External metal
cover
cover
28.6
Ambient
25.0
65
Speaker
Maximum
Power
T2 coil
95.9
Input current= 0.68A to 2.4A
Unit shutdown instantly. No hazards,
no damaged.
no damaged.
T2 core
86.4
T1 coil
73.5
T1 core
73.4
DT1 coil
76.3
DT1 core
73.9
CT1 coil
96.1
CT1 core
95.8
External metal
cover
cover
37.7
Ambient
25.5
66
Speaker
(1/3W)
Maximum
Power
T2 coil
71.2
Input current= 0.68A to 0.98A
Unit operated normally. No
damaged, no hazards.
Unit operated normally. No
damaged, no hazards.
T2 core
71
T1 coil
56.1
T1 core
55.6
DT1 coil
55.3
Click on the first or last page to see other SUB 250P (serv.man2) service manuals if exist.