Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Construction details:
- Three layers insulation tape used between input windings and output windings.
- Outer winding is input winding and wrapped three layers insulation.
- 3.0mm width margin tape provided on both side of each winding.
- Core is considered as floating part.
- Tube used on each exit windings.
- Bottom core is overlapped 2 layers insulation tape
- Three layers insulation tape used between input windings and output windings.
- Outer winding is input winding and wrapped three layers insulation.
- 3.0mm width margin tape provided on both side of each winding.
- Core is considered as floating part.
- Tube used on each exit windings.
- Bottom core is overlapped 2 layers insulation tape
For transformer CT1
- Input wing to output winding (internal)
250
420
4.0
5.4
5.0
5.4
- Input winding to core (internal)
250
420
2.0
Tube
used
2.5
Tube
used
- Output winding to core (internal)
250
420
2.0
2.0
2.5
2.5
- Input pin to core (external)
250
420
2.0
3.7
2.5
3.7
- Output pin to core (external)
250
420
2.0
3.7
2.5
3.7
Page 45 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Construction details:
- Input winding and output winding are separated by design of partition wall.
- Input winding covered by sleeving tube.
- Top core overlapped 2 layers insulation tape.
- Core is considered as floating part.
- Input winding and output winding are separated by design of partition wall.
- Input winding covered by sleeving tube.
- Top core overlapped 2 layers insulation tape.
- Core is considered as floating part.
For transformer DT1
- Input wing to output winding (internal)
250
420
4.0
6.0
5.0
6.0
- windings to exit pins (external)
250
420
4.0
10.8
5.0
10.8
- Input winding to core (internal)
250
420
2.0
3.0
2.5
3.0
Page 46 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
- Output winding to core (internal)
250
420
2.0
3.0
2.5
3.0
- Input pin to core (external)
250
420
2.0
4.0
2.5
4.0
- Output pin to core (external)
250
420
2.0
4.0
2.5
4.0
Construction details:
- Three layers insulation tape used between input windings and output windings.
- Outer winding is input winding and wrapped three layers insulation.
- 3.0mm width margin tape provided on both side of each winding.
- Core is considered as floating part.
- Tube used on each exit windings.
- Three layers insulation tape used between input windings and output windings.
- Outer winding is input winding and wrapped three layers insulation.
- 3.0mm width margin tape provided on both side of each winding.
- Core is considered as floating part.
- Tube used on each exit windings.
14
TABLE: list of critical components and materials
P
Page 47 of 54
Report No.: 11034065 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Object / part No.
Manufacturer/
trademark
Type / model
Technical data
Standard
Mark(s) of
conformity
1)
For unit:
Wood enclosure --
--
Min. 6.0mm thick
--
--
Rear metal plate Various
Various
Metallic, Min.
thickness 2.0mm
thickness 2.0mm
--
--
CHI MEI
Corporation
Corporation
PA-765A(+)
V-0, min. 80°C,
thickness 2.5mm
thickness 2.5mm
UL 94
UL (E56070)
Power switch
CHILY Precision
Industrial Co., Ltd
Industrial Co., Ltd
3024
250Vac/16A,
Number of
operating cycles:
10E3, V-0
Number of
operating cycles:
10E3, V-0
IEC 61058-1,
EN 61058-1+A2:
2008,
UL 61058-1,
GB15092.1
EN 61058-1+A2:
2008,
UL 61058-1,
GB15092.1
ENEC(FI),
UL
(E68037),
CQC
UL
(E68037),
CQC
Speaker for
subwoofer
subwoofer
Various
Various
4Ω, Max. 160W
--
--
PWB material
other than
power board
other than
power board
Various
Various
V-1 or better, min.
105°C
105°C
UL 796
UL
Primary
connector
(connect to CN1
of power board)
connector
(connect to CN1
of power board)
Jowle Technology
Co., Ltd
Co., Ltd
A3961H
series,
Housing type
series,
Housing type
250Vac, 7A, 85°C
IEC 61984,
EN 61984: 2001,
UL 1977
EN 61984: 2001,
UL 1977
VDE, UL
Weli Sheng
Px-I39606,
250Vac, 7A, 70°C
IEC 61984,
EN 61984: 2001,
UL 1977
EN 61984: 2001,
UL 1977
TUV SUD,
UL
(E149293)
UL
(E149293)
Strain relief
Heavy Power Co
Ltd
Ltd
4K-4
PVC plastic
Bushing, outside:
13.5 x 10.3 mm,
inside: 8.5 x 10.3
mm
Bushing, outside:
13.5 x 10.3 mm,
inside: 8.5 x 10.3
mm
UL 635
UL
(E107293)
(E107293)
For non-detachable power cord set (US type for Model: SUB 250P/100, SUB 250P):
- Power plug
I-Sheng Electric
Wire & Cable Co
Ltd
Wire & Cable Co
Ltd
SP-12N
10A, 125V, 1-15P
Plug
Plug
NEMA 1-15P
UL (E55943)
- Power cord
I-Sheng Electric
Wire & Cable Co
Ltd
Wire & Cable Co
Ltd
SPT-1,
SPT-2,
NISPT-2,
SPE-2,
NISPE-2
SPT-2,
NISPT-2,
SPE-2,
NISPE-2
Flexible cord, 18
AWG, min., 1.5m
long min. and 4.5m
long max.
AWG, min., 1.5m
long min. and 4.5m
long max.
UL 62
UL (E88265)
For non-detachable power cord set (EU type for Model: SUB 250P/230):
- Power plug
I-Sheng Electric
Wire & Cable Co
Ltd
Wire & Cable Co
Ltd
SP-021A
250Vac, 2.5A
EN 50075: 1990 VDE
- Power cord
I-Sheng Electric
Wire & Cable Co
Ltd
Wire & Cable Co
Ltd
H03VVH2-F
2 X 0.75mm
2
DIN VDE 0281-5 VDE