DOWNLOAD JBL SUB 250P (serv.man2) Service Manual ↓ Size: 2.17 MB | Pages: 112 in PDF or view online for FREE

Model
SUB 250P (serv.man2)
Pages
112
Size
2.17 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sub-250p-sm2.pdf
Date

JBL SUB 250P (serv.man2) EMC - CB Certificate ▷ View online

Page 4 of 54 
Report No.: 11034065 001 
 
TRF No. IEC60065K 
 
 
 
Copy of marking plate: 
The artwork below may be only a draft. The use of certification marks on a product must be authorized by 
the respective NCBs that own these marks. 
 
Page 5 of 54 
Report No.: 11034065 001 
 
TRF No. IEC60065K 
 
 
 
 
Copy of marking plate: 
The artwork below may be only a draft. The use of certification marks on a product must be authorized by 
the respective NCBs that own these marks. 
 
Page 6 of 54 
Report No.: 11034065 001 
 
TRF No. IEC60065K 
 
 
 
 
Test item particulars ..................................................... :   
Classification of installation and use ............................ :  Class II, Portable equipment 
Supply Connection ....................................................... :  Non-detachable power cord 
 ...................................................................................... :   
Possible test case verdicts: 
 
- test case does not apply to the test object ................. :  N/A (Not Applicable) 
- test object does meet the requirement ....................... :  P (Pass) 
- test object does not meet the requirement ................. :  F (Fail) 
Testing: 
 
Date of receipt of test item ............................................ :  August, 2013 
Date (s) of performance of tests ................................... :  August, 2013 
 
 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
Throughout this report a 
 comma / 
 point is used as the decimal separator. 
 
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02: 
The application for obtaining a CB Test Certificate 
includes more than one factory location and a 
declaration from the Manufacturer stating that the 
sample(s) submitted for evaluation is (are) 
representative of the products from each factory has 
been provided ................................................................ : 
 Yes 
 Not applicable 
When differences exist; they shall be identified in the General product information section. 
Name and address of factory (ies) .............................. :  DONGGUAN MEILOON ACOUSTIC 
EQUIPMENTS CO., LTD. 
NO. 77, Yuanlin Road, Feng Huang, Guang Ind., 
Estate Tangxia, Dongguan, Guangdong Province, 
P.R. China 
General product information: 
Product Description 
• 
This equipment under test (EUT) is a powered subwoofer for the use in the scope of EN 60065. 
• 
Models SUB 250P/100 and SUB 250P are identical to each other and input voltage for these two 
models is 100-120Vac. 
• 
Models SUB 250P/230 and SUB 250P/230-C are identical to each other and input voltage for these 
two models is 220-240Vac. 
• 
One power board used for all models. Jump (J2) is used to switch different input voltage (J2 short for 
input 100-120Vac, J2 open for 220-240Vac) and is not user accessible. 
• 
All components except subwoofer speaker are contained in an enclosure which consists of plastic 
chassis (flammability rated V-1) and metal plate. No ventilation opening provided on this enclosure. 
Engineering Considerations 
 
• 
The product was submitted and tested for use at the maximum ambient temperature (Tma) 
Page 7 of 54 
Report No.: 11034065 001 
 
TRF No. IEC60065K 
 
 
 
permitted by the manufacturer’s specification of: 35°C. 
• 
The product is intended to be used in environment of pollution degree 2. 
• 
The product is intended for use on the following power systems: TN. 
• 
The equipment disconnect device is considered to be: plug. 
• 
Following transformers are provided (See subclause 1.5.4): Transformer (T2, CT1, DT1 and T1) is an 
isolating transformer. 
• 
Components bridging insulation other than functional: 
Components 
ID 
Bridging location 
Bridging insulation 
Capacitor 
CY1, 
CY2, 
CY3, 
CY4 
Primary-to-secondary 
Double/Reinforced (see subclause 
8.6) 
-- 
Primary-to-earth 
Basic  (see subclause 8.5) 
CX1, 
CX2 
Across mains 
conductors 
-- 
Resistor  
-- 
Primary-to-secondary 
Double/Reinforced (see subclause 
8.6) 
-- 
Primary-to-earth 
Basic (see subclause 8.5) 
R5, R8, 
R5A, 
R8A 
Across mains 
conductors 
-- 
VDR  
-- 
Primary-to-earth 
Basic 
ZNR1 
Across mains 
conductors 
-- 
 
• 
Following solid insulation other than wiring insulation are provided (See subclause 8.8): 
Type of Insulation 
Type of solid insulation (distance through 
insulation / thin sheet 
Location 
Layer or 
thickness 
Reinforced insulation 
distance through insulation 
Plastic 
enclosure 
2.5mm 
• 
Following devices were considered protective devices (See subclause 14.5): Fuse (F1). 
Additional Information 
• 
The temperature measurements were carried out with the apparatus positioned in testing box in 
accordance with subclause 4.1.4 
• 
The power supply unit used in the product is not a certified product. Hence, compliance has been 
evaluated in this report. 
• 
The equipment is for use in multimedia systems and was investigated additionally to IEC GUIDE 
112. 
• 
The Label in Copy of marking plate is a draft of an artwork pending approval by National Certification 
Bodies and it shall not be affixed to products prior to such an approval. 
• 
The plug was investigated and found in compliance with applicable parts of corresponding plug 
standard:  EN 50075. 
• 
The connector part of the removable plug portion was investigated and found in compliance with 
applicable parts of IEC 61984. 
• 
Some components are pre-certified, which have been evaluated according to the relevant 
requirements of IEC 60065, are employed in this product.  Their suitability of use has been checked 
accordingly. 
Markings and Instructions 
• 
The instructions for use provided information that stating the apparatus shall not be exposed to dripping 
Page of 112
Display