Page 8 of 54 
Report No.: 11034065 001 
 
TRF No. IEC60065K 
 
 
 
or splashing and that no objects filled with liquids shall be placed on the apparatus (see subclause 
5.4.1). 
• 
The installation instructions provided with instructions of correct and safe installation and interconnection 
of the apparatus in multimedia systems. (see subclause 5.4.1). 
• 
Transformers are marked with following: 
Transformer 
Marking 
T1, T2, CT1, DT1 
Manufacturer and type (see 
appended table 14) 
The product also marked with: 
• 
Fuse marking (See subclause 14.5.2.2): F1 120V: T6.3AL/ 250V; F1 230V: T4.0AL/250V. 
• 
 (ISO 7000-0434) in manufacturer’s service documentation for each critical component. 
• 
(IEC 60417-5007) for "ON” of the switch (see subclause 5.4.2). 
• 
(IEC 60417-5008) for “OFF” of the switch (see subclause 5.4.2). 
Page 9 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
General requirements 
 
Safety class of the apparatus  .................................. :  See Test item particulars 
 
4 
General test conditions 
4.1.4 
Ventilation instructions require the use of the test 
box  
See Additional Information. 
 
5 
Marking and instructions 
 
Comprehensible and easily discernible 
The markings are permanent, 
comprehensible and easily 
discernible. 
 
Permanent durability against water and petroleum 
spirit  
 
5.1 
a) Identification, maker  ............................................. :  See Copy of marking plates 
 
b) Model number or type reference .......................... :  See Copy of marking plates 
 
c) Class II symbol if applicable  ................................ :  See Copy of marking plates 
 
d) Nature of supply .................................................... :  See Copy of marking plates 
 
e) Rated supply voltage  ........................................... :  See Copy of marking plates 
 
f) Mains frequency if safety dependant  ................... :  See Copy of marking plates 
 
g) Rated current or power consumption for 
apparatus supplied by supply apparatus for general 
use  ............................................................................ : 
 
N/A 
 
Measured current or power consumption  ............... :   
N/A 
 
Deviation % (max 10%)  ........................................... :   
N/A 
 
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply . : 
See Copy of marking plates 
 
Measured current or power consumption  ............... :  See appended table 7.1. 
 
Measured current or power consumption for 
Television set  ........................................................... : 
 
N/A 
 
Deviation % (max 10%)  ........................................... :   
5.2 
a) Earth terminal  
 
N/A 
 
b) Hazardous live terminals  
 
N/A 
 
c) Markings on supply output terminals 
 
N/A 
5.3 
a) Use of triangle with exclamation mark  
Triangle with exclamation mark 
is marked on each critical 
component in circuit diagram. 
 
b) marking on loudspeaker grille, IEC 60417-5036 
 
N/A 
5.4 
Instructions for use 
 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
See Markings and 
Instructions.
 
Page 10 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
b) Hazardous live terminals, instructions for wiring   
 
N/A 
 
c) Instructions for replacing lithium battery  
 
N/A 
 
d) Class I earth connection warning  
 
N/A 
 
e) Instructions for multimedia system connection  
See Markings and 
Instructions.
 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
 
N/A 
 
g) Warning: battery exposure to heat  
 
N/A 
 
h) Warning: protective film on CRT face  
 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
Inlet as the disconnect device. 
 
c) Instructions for permanently connected equipment    
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
Inlet as the disconnect device. 
However, an all pole power 
switch is used and marked 
according to IEC 60417-
5007/5008. 
N/A 
 
Hazardous radiation 
N/A 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1:2007
 ................................................................................... : 
 
N/A 
 
Emission limits under fault conditions  ..................... :   
N/A 
 
7 
Heating under normal operating conditions 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table) 
7.1.1 
Temperature rise of accessible parts  
(see appended table) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
 
N/A 
7.1.4 
Temperature rise of windings  
(see appended table) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
Certified connector used. See 
appended table 14. 
 
Constructional requirements with regard to the protection against electric 
shock 
Page 11 of 54 
Report No.: 11034065 001 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
Considered. 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
No hygroscopic material is 
used as insulation of 
hazardous live parts. 
Humidity treatment was 
conducted under the required 
relative humidity and  following 
conditioning period: 120h 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand  
No risk of electric shock. See 
8.6. 
8.5 
Class I equipment  
 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 
N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
See below. 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
Hazardous live parts to 
accessible parts are separated 
by either reinforced or double 
insulation. 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
Transformer (T1, T2, CT1 and 
DT1) bridging reinforced or 
double insulation complying 
with 14.3. 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
Y1-capacitor (CY1, CY2, CY3, 
CY4) bridging Reinforced 
insulation. See 14.2.1 b). 
8.7 
This clause is void  
 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
Transformer (DT1 and  T2) 
bobbin thickness is 0.8mm 
min. 
Page of 112