Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 45 of 97
 
 
Current Test Result Summary (Run time) 
EUT: 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature: 
23℃ 
Relative Humidity: 47% 
Pressure: 1010 
hPa 
Test Power : 
AC 230V/50Hz 
Highest parameter values during test: 
V_RMS (Volts):  229.51 
Frequency(Hz): 50.00 
I_Peak (Amps):  0.609 
I_RMS (Amps): 
0.106 
I_Fund (Amps):  0.042 
Crest Factor: 
6.505 
Power (Watts): 
7.9 
Power Factor: 
0.336 
Test Mode : 
AUX IN / CNTR, TianBao 
 
Harm#Harms(avg)100%Limit%of Limit Harms(max) 150%Limit %of Limit  Status 
 
 
2  0.001 1.080  0.0 
0.002 1.620  0.12 
Pass 
 
3  0.033 2.300  1.5 
0.035 3.450  1.01 
Pass 
 
4  0.001 0.430  0.0 
0.002 0.645  0.26 
Pass 
 
5  0.033 1.140  2.9 
0.033 1.710  1.93 
Pass 
 
6  0.001 0.300  0.0 
0.001 0.450  0.28 
Pass 
 
7  0.032 0.770  4.1 
0.032 1.155  2.79 
Pass 
 
8  0.001 0.230  0.0 
0.001 0.345  0.30 
Pass 
 
9  0.031 0.400  7.6 
0.031 0.600  5.13 
Pass 
 
10  0.001 0.184  0.0 
0.001 0.276  0.39 
Pass 
 
11  0.029 0.330  8.8 
0.029 0.495  5.93 
Pass 
 
12  0.002 0.153  0.0 
0.002 0.230  0.96 
Pass 
 
13  0.027 0.210  13.0 
0.028 0.315  8.78 
Pass 
 
14  0.001 0.131  0.0 
0.001 0.197  0.50 
Pass 
 
15  0.025 0.150  17.0 
0.026 0.225 11.44 
Pass 
 
16  0.001 0.115  0.0 
0.001 0.173  0.55 
Pass 
 
17  0.023 0.132  17.8 
0.024 0.199 11.89 
Pass 
 
18  0.001 0.102  0.0 
0.001 0.153  0.59 
Pass 
 
19  0.021 0.118  18.0 
0.021 0.178 12.07 
Pass 
 
20  0.001 0.092  0.0 
0.001 0.138  0.64 
Pass 
 
21  0.019 0.107  17.9 
0.019 0.161 11.97 
Pass 
 
22  0.001 0.084  0.0 
0.001 0.125  0.65 
Pass 
 
23  0.017 0.098  17.3 
0.017 0.147 11.57 
Pass 
 
24  0.001 0.077  0.0 
0.001 0.115  0.67 
Pass 
 
25  0.015 0.090  16.3 
0.015 0.135 10.98 
Pass 
 
26  0.001 0.071  0.0 
0.001 0.106  0.66 
Pass 
 
27  0.013 0.083  15.0 
0.013 0.125 10.12 
Pass 
 
28  0.001 0.066  0.0 
0.001 0.099  0.69 
Pass 
 
29  0.010 0.078  13.4 
0.011 0.116  9.10 
Pass 
 
30  0.000 0.061  0.0 
0.001 0.092  0.61 
Pass 
 
31  0.008 0.073  11.6 
0.009 0.109  7.85 
Pass 
 
32  0.000 0.058  0.0 
0.001 0.086  0.62 
Pass 
 
33  0.007 0.068  9.7 
0.007 0.102  6.63 
Pass 
 
34  0.000 0.054  0.0 
0.000 0.081  0.55 
Pass 
 
35  0.005 0.064  7.7 
0.005 0.096  5.41 
Pass 
 
36  0.000 0.051  0.0 
0.000 0.077  0.47 
Pass 
 
37  0.003 0.061  0.0 
0.004 0.091  4.27 
Pass 
 
38  0.000 0.048  0.0 
0.000 0.073  0.47 
Pass 
 
39  0.002 0.058  0.0 
0.003 0.087  3.14 
Pass 
 
40  0.000 0.046  0.0 
0.000 0.069  0.39 
Pass 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 46 of 97
 
 
Voltage Source Verification Data (Run time) 
EUT: 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature: 
23℃ 
Relative Humidity: 47% 
Pressure: 1010 
hPa 
Test Power : 
AC 230V/50Hz 
Highest parameter values during test: 
V_RMS (Volts):  229.51 
Frequency(Hz): 50.00 
I_Peak (Amps):  0.609 
I_RMS (Amps): 
0.106 
I_Fund (Amps):  0.042 
Crest Factor: 
6.505 
Power (Watts): 
7.9 
Power Factor: 
0.336 
Test Mode: 
AUX IN / CNTR, TianBao 
 
Harm#  Harmonics V-rms 
Limit V-rms 
% of Limit 
Status 
 
 2 
0.127 
0.459 
27.65 
OK 
 3 
0.521 
2.065 
25.24 
OK 
 4 
0.064 
0.459 
13.84 
OK 
 5 
0.081 
0.918 
8.85 
OK 
 6 
0.033 
0.459 
7.19 
OK 
 7 
0.036 
0.689 
5.20 
OK 
 8 
0.017 
0.459 
3.72 
OK 
 9 
0.027 
0.459 
5.84 
OK 
 10 
0.022 
0.459 
4.71 
OK 
 11 
0.041 
0.229 
17.75 
OK 
 12 
0.020 
0.229 
8.86 
OK 
 13 
0.025 
0.229 
10.98 
OK 
 14 
0.009 
0.229 
4.13 
OK 
 15 
0.018 
0.229 
7.73 
OK 
 16 
0.011 
0.229 
4.89 
OK 
 17 
0.023 
0.230 
9.94 
OK 
 18 
0.015 
0.230 
6.70 
OK 
 19 
0.024 
0.229 
10.30 
OK 
 20 
0.015 
0.229 
6.49 
OK 
 21 
0.022 
0.230 
9.56 
OK 
 22 
0.013 
0.230 
5.49 
OK 
 23 
0.019 
0.229 
8.36 
OK 
 24 
0.008 
0.229 
3.65 
OK 
 25 
0.022 
0.229 
9.44 
OK 
 26 
0.007 
0.229 
3.08 
OK 
 27 
0.015 
0.229 
6.71 
OK 
 28 
0.007 
0.229 
3.13 
OK 
 29 
0.014 
0.229 
5.90 
OK 
 30 
0.006 
0.230 
2.47 
OK 
 31 
0.012 
0.229 
5.18 
OK 
 32 
0.006 
0.229 
2.66 
OK 
 33 
0.014 
0.229 
6.06 
OK 
 34 
0.003 
0.229 
1.33 
OK 
 35 
0.009 
0.229 
3.93 
OK 
 36 
0.003 
0.230 
1.50 
OK 
 37 
0.008 
0.229 
3.48 
OK 
 38 
0.004 
0.229 
1.93 
OK 
 39 
0.004 
0.230 
1.67 
OK 
 40 
0.006 
0.229 
2.67 
OK 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 47 of 97
 
 
Harmonics – Class-A per Ed. 3.2(Run time)
 
EUT: 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature: 
23℃ 
Relative Humidity: 47% 
Pressure: 1010 
hPa 
Test Power : 
AC 230V/50Hz 
Test Mode : 
AUX IN / CNTR, HanWei 
 
Current & voltage waveforms 
   
 
-0.6
-0.4
-0.2
0.0
0.2
0.4
0.6
-300
-200
-100
0
100
200
300
  
Current (Amps)
Voltage (Volts)
 
Limits 
 
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
  
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
 
 
Test result:    Pass          Worst harmonic was #17 with 14.38% of the limit.   
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 48 of 97
 
 
Current Test Result Summary (Run time) 
EUT: 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature: 
23℃ 
Relative Humidity: 47% 
Pressure: 1010 
hPa 
Test Power : 
AC 230V/50Hz 
Highest parameter values during test: 
V_RMS (Volts):  229.51 
Frequency(Hz): 50.00 
I_Peak (Amps):  0.479 
I_RMS (Amps): 
0.094 
I_Fund (Amps):  0.035 
Crest Factor: 
5.422 
Power (Watts): 
7.3 
Power Factor: 
0.367 
Test Mode : 
AUX IN / CNTR, HanWei 
 
Harm#Harms(avg)100%Limit%of Limit Harms(max) 150%Limit %of Limit  Status 
 
 
2  0.001 1.080  0.0 
0.002 1.620  0.10 
Pass 
 
3  0.031 2.300  1.3 
0.032 3.450  0.92 
Pass 
 
4  0.001 0.430  0.0 
0.001 0.645  0.22 
Pass 
 
5  0.030 1.140  2.6 
0.030 1.710  1.76 
Pass 
 
6  0.001 0.300  0.0 
0.001 0.450  0.22 
Pass 
 
7  0.029 0.770  3.7 
0.029 1.155  2.53 
Pass 
 
8  0.001 0.230  0.0 
0.001 0.345  0.25 
Pass 
 
9  0.027 0.400  6.8 
0.027 0.600  4.57 
Pass 
 
10  0.001 0.184  0.0 
0.001 0.276  0.33 
Pass 
 
11  0.025 0.330  7.7 
0.026 0.495  5.21 
Pass 
 
12  0.002 0.153  0.0 
0.002 0.230  0.89 
Pass 
 
13  0.023 0.210  11.2 
0.024 0.315  7.56 
Pass 
 
14  0.001 0.131  0.0 
0.001 0.197  0.37 
Pass 
 
15  0.021 0.150  14.2 
0.022 0.225  9.58 
Pass 
 
16  0.001 0.115  0.0 
0.001 0.173  0.38 
Pass 
 
17  0.019 0.132  14.4 
0.019 0.199  9.67 
Pass 
 
18  0.001 0.102  0.0 
0.001 0.153  0.42 
Pass 
 
19  0.017 0.118  14.0 
0.017 0.178  9.48 
Pass 
 
20  0.001 0.092  0.0 
0.001 0.138  0.45 
Pass 
 
21  0.014 0.107  13.3 
0.014 0.161  8.96 
Pass 
 
22  0.000 0.084  0.0 
0.001 0.125  0.46 
Pass 
 
23  0.012 0.098  12.2 
0.012 0.147  8.21 
Pass 
 
24  0.000 0.077  0.0 
0.001 0.115  0.49 
Pass 
 
25  0.010 0.090  10.7 
0.010 0.135  7.27 
Pass 
 
26  0.001 0.071  0.0 
0.001 0.106  0.73 
Pass 
 
27  0.008 0.083  9.0 
0.008 0.125  6.15 
Pass 
 
28  0.000 0.066  0.0 
0.000 0.099  0.50 
Pass 
 
29  0.006 0.078  7.2 
0.006 0.116  4.95 
Pass 
 
30  0.000 0.061  0.0 
0.000 0.092  0.44 
Pass 
 
31  0.004 0.073  0.0 
0.004 0.109  3.66 
Pass 
 
32  0.000 0.058  0.0 
0.000 0.086  0.39 
Pass 
 
33  0.002 0.068  0.0 
0.002 0.102  2.45 
Pass 
 
34  0.000 0.054  0.0 
0.000 0.081  0.41 
Pass 
 
35  0.001 0.064  0.0 
0.001 0.096  1.33 
Pass 
 
36  0.000 0.051  0.0 
0.000 0.077  0.45 
Pass 
 
37  0.001 0.061  0.0 
0.001 0.091  0.95 
Pass 
 
38  0.000 0.048  0.0 
0.000 0.073  0.51 
Pass 
 
39  0.001 0.058  0.0 
0.001 0.087  1.69 
Pass 
 
40  0.000 0.046  0.0 
0.000 0.069  0.43 
Pass 
 
Page of 97
Display

Click on the first or last page to see other SB 300 (serv.man6) service manuals if exist.