JBL SB 300 (serv.man6) EMC - CB Certificate ▷ View online
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 45 of 97
Current Test Result Summary (Run time)
EUT:
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature:
23℃
Relative Humidity: 47%
Pressure: 1010
hPa
Test Power :
AC 230V/50Hz
Highest parameter values during test:
V_RMS (Volts): 229.51
V_RMS (Volts): 229.51
Frequency(Hz): 50.00
I_Peak (Amps): 0.609
I_RMS (Amps):
0.106
I_Fund (Amps): 0.042
Crest Factor:
6.505
Power (Watts):
7.9
Power Factor:
0.336
Test Mode :
AUX IN / CNTR, TianBao
Harm#Harms(avg)100%Limit%of Limit Harms(max) 150%Limit %of Limit Status
2 0.001 1.080 0.0
0.002 1.620 0.12
Pass
3 0.033 2.300 1.5
0.035 3.450 1.01
Pass
4 0.001 0.430 0.0
0.002 0.645 0.26
Pass
5 0.033 1.140 2.9
0.033 1.710 1.93
Pass
6 0.001 0.300 0.0
0.001 0.450 0.28
Pass
7 0.032 0.770 4.1
0.032 1.155 2.79
Pass
8 0.001 0.230 0.0
0.001 0.345 0.30
Pass
9 0.031 0.400 7.6
0.031 0.600 5.13
Pass
10 0.001 0.184 0.0
0.001 0.276 0.39
Pass
11 0.029 0.330 8.8
0.029 0.495 5.93
Pass
12 0.002 0.153 0.0
0.002 0.230 0.96
Pass
13 0.027 0.210 13.0
0.028 0.315 8.78
Pass
14 0.001 0.131 0.0
0.001 0.197 0.50
Pass
15 0.025 0.150 17.0
0.026 0.225 11.44
Pass
16 0.001 0.115 0.0
0.001 0.173 0.55
Pass
17 0.023 0.132 17.8
0.024 0.199 11.89
Pass
18 0.001 0.102 0.0
0.001 0.153 0.59
Pass
19 0.021 0.118 18.0
0.021 0.178 12.07
Pass
20 0.001 0.092 0.0
0.001 0.138 0.64
Pass
21 0.019 0.107 17.9
0.019 0.161 11.97
Pass
22 0.001 0.084 0.0
0.001 0.125 0.65
Pass
23 0.017 0.098 17.3
0.017 0.147 11.57
Pass
24 0.001 0.077 0.0
0.001 0.115 0.67
Pass
25 0.015 0.090 16.3
0.015 0.135 10.98
Pass
26 0.001 0.071 0.0
0.001 0.106 0.66
Pass
27 0.013 0.083 15.0
0.013 0.125 10.12
Pass
28 0.001 0.066 0.0
0.001 0.099 0.69
Pass
29 0.010 0.078 13.4
0.011 0.116 9.10
Pass
30 0.000 0.061 0.0
0.001 0.092 0.61
Pass
31 0.008 0.073 11.6
0.009 0.109 7.85
Pass
32 0.000 0.058 0.0
0.001 0.086 0.62
Pass
33 0.007 0.068 9.7
0.007 0.102 6.63
Pass
34 0.000 0.054 0.0
0.000 0.081 0.55
Pass
35 0.005 0.064 7.7
0.005 0.096 5.41
Pass
36 0.000 0.051 0.0
0.000 0.077 0.47
Pass
37 0.003 0.061 0.0
0.004 0.091 4.27
Pass
38 0.000 0.048 0.0
0.000 0.073 0.47
Pass
39 0.002 0.058 0.0
0.003 0.087 3.14
Pass
40 0.000 0.046 0.0
0.000 0.069 0.39
Pass
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 46 of 97
Voltage Source Verification Data (Run time)
EUT:
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature:
23℃
Relative Humidity: 47%
Pressure: 1010
hPa
Test Power :
AC 230V/50Hz
Highest parameter values during test:
V_RMS (Volts): 229.51
V_RMS (Volts): 229.51
Frequency(Hz): 50.00
I_Peak (Amps): 0.609
I_RMS (Amps):
0.106
I_Fund (Amps): 0.042
Crest Factor:
6.505
Power (Watts):
7.9
Power Factor:
0.336
Test Mode:
AUX IN / CNTR, TianBao
Harm# Harmonics V-rms
Limit V-rms
% of Limit
Status
2
0.127
0.459
27.65
OK
3
0.521
2.065
25.24
OK
4
0.064
0.459
13.84
OK
5
0.081
0.918
8.85
OK
6
0.033
0.459
7.19
OK
7
0.036
0.689
5.20
OK
8
0.017
0.459
3.72
OK
9
0.027
0.459
5.84
OK
10
0.022
0.459
4.71
OK
11
0.041
0.229
17.75
OK
12
0.020
0.229
8.86
OK
13
0.025
0.229
10.98
OK
14
0.009
0.229
4.13
OK
15
0.018
0.229
7.73
OK
16
0.011
0.229
4.89
OK
17
0.023
0.230
9.94
OK
18
0.015
0.230
6.70
OK
19
0.024
0.229
10.30
OK
20
0.015
0.229
6.49
OK
21
0.022
0.230
9.56
OK
22
0.013
0.230
5.49
OK
23
0.019
0.229
8.36
OK
24
0.008
0.229
3.65
OK
25
0.022
0.229
9.44
OK
26
0.007
0.229
3.08
OK
27
0.015
0.229
6.71
OK
28
0.007
0.229
3.13
OK
29
0.014
0.229
5.90
OK
30
0.006
0.230
2.47
OK
31
0.012
0.229
5.18
OK
32
0.006
0.229
2.66
OK
33
0.014
0.229
6.06
OK
34
0.003
0.229
1.33
OK
35
0.009
0.229
3.93
OK
36
0.003
0.230
1.50
OK
37
0.008
0.229
3.48
OK
38
0.004
0.229
1.93
OK
39
0.004
0.230
1.67
OK
40
0.006
0.229
2.67
OK
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 47 of 97
Harmonics – Class-A per Ed. 3.2(Run time)
EUT:
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature:
23℃
Relative Humidity: 47%
Pressure: 1010
hPa
Test Power :
AC 230V/50Hz
Test Mode :
AUX IN / CNTR, HanWei
Current & voltage waveforms
-0.6
-0.4
-0.2
0.0
0.2
0.4
0.6
-300
-200
-100
0
100
200
300
Current (Amps)
Voltage (Volts)
Limits
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
Test result: Pass Worst harmonic was #17 with 14.38% of the limit.
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 48 of 97
Current Test Result Summary (Run time)
EUT:
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature:
23℃
Relative Humidity: 47%
Pressure: 1010
hPa
Test Power :
AC 230V/50Hz
Highest parameter values during test:
V_RMS (Volts): 229.51
V_RMS (Volts): 229.51
Frequency(Hz): 50.00
I_Peak (Amps): 0.479
I_RMS (Amps):
0.094
I_Fund (Amps): 0.035
Crest Factor:
5.422
Power (Watts):
7.3
Power Factor:
0.367
Test Mode :
AUX IN / CNTR, HanWei
Harm#Harms(avg)100%Limit%of Limit Harms(max) 150%Limit %of Limit Status
2 0.001 1.080 0.0
0.002 1.620 0.10
Pass
3 0.031 2.300 1.3
0.032 3.450 0.92
Pass
4 0.001 0.430 0.0
0.001 0.645 0.22
Pass
5 0.030 1.140 2.6
0.030 1.710 1.76
Pass
6 0.001 0.300 0.0
0.001 0.450 0.22
Pass
7 0.029 0.770 3.7
0.029 1.155 2.53
Pass
8 0.001 0.230 0.0
0.001 0.345 0.25
Pass
9 0.027 0.400 6.8
0.027 0.600 4.57
Pass
10 0.001 0.184 0.0
0.001 0.276 0.33
Pass
11 0.025 0.330 7.7
0.026 0.495 5.21
Pass
12 0.002 0.153 0.0
0.002 0.230 0.89
Pass
13 0.023 0.210 11.2
0.024 0.315 7.56
Pass
14 0.001 0.131 0.0
0.001 0.197 0.37
Pass
15 0.021 0.150 14.2
0.022 0.225 9.58
Pass
16 0.001 0.115 0.0
0.001 0.173 0.38
Pass
17 0.019 0.132 14.4
0.019 0.199 9.67
Pass
18 0.001 0.102 0.0
0.001 0.153 0.42
Pass
19 0.017 0.118 14.0
0.017 0.178 9.48
Pass
20 0.001 0.092 0.0
0.001 0.138 0.45
Pass
21 0.014 0.107 13.3
0.014 0.161 8.96
Pass
22 0.000 0.084 0.0
0.001 0.125 0.46
Pass
23 0.012 0.098 12.2
0.012 0.147 8.21
Pass
24 0.000 0.077 0.0
0.001 0.115 0.49
Pass
25 0.010 0.090 10.7
0.010 0.135 7.27
Pass
26 0.001 0.071 0.0
0.001 0.106 0.73
Pass
27 0.008 0.083 9.0
0.008 0.125 6.15
Pass
28 0.000 0.066 0.0
0.000 0.099 0.50
Pass
29 0.006 0.078 7.2
0.006 0.116 4.95
Pass
30 0.000 0.061 0.0
0.000 0.092 0.44
Pass
31 0.004 0.073 0.0
0.004 0.109 3.66
Pass
32 0.000 0.058 0.0
0.000 0.086 0.39
Pass
33 0.002 0.068 0.0
0.002 0.102 2.45
Pass
34 0.000 0.054 0.0
0.000 0.081 0.41
Pass
35 0.001 0.064 0.0
0.001 0.096 1.33
Pass
36 0.000 0.051 0.0
0.000 0.077 0.45
Pass
37 0.001 0.061 0.0
0.001 0.091 0.95
Pass
38 0.000 0.048 0.0
0.000 0.073 0.51
Pass
39 0.001 0.058 0.0
0.001 0.087 1.69
Pass
40 0.000 0.046 0.0
0.000 0.069 0.43
Pass
Click on the first or last page to see other SB 300 (serv.man6) service manuals if exist.