DOWNLOAD JBL SB 300 (serv.man6) Service Manual ↓ Size: 1.51 MB | Pages: 97 in PDF or view online for FREE

Model
SB 300 (serv.man6)
Pages
97
Size
1.51 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sb-300-sm6.pdf
Date

JBL SB 300 (serv.man6) EMC - CB Certificate ▷ View online

Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 61 of 97
 
 
 
EUT: 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature: 
23℃ 
Relative Humidity: 47% 
Pressure: 1010 
hPa 
Test Power : 
AC 230V/50Hz 
Test Mode : 
AUX IN / Subwoofer, HanWei 
 
 
Pst
i
 and limit line  
Limits 
0.25
0.50
0.75
1.00
  
Pst
12:01:05
 
Time is too short for Plt plot
 
 
 
Parameter values recorded during the test: 
 
Vrms at the end of test (Volt): 229.45 
Highest dt (%): 
0.0 Test limit (%):
3.30 
PASS 
Time(mS) > dt: 
0.0 Test limit (mS):
500.0 
PASS 
Highest dc (%): 
0.00 Test limit (%):
3.30 
PASS 
Highest dmax (%): 
0.00 Test limit (%):
4.00 
PASS 
Highest Pst (10 min. period): 
0.064 Test limit: 
1.000 
PASS 
Highest Plt (2 hr. period): 
0.028 Test limit: 
0.650 
PASS 
 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 62 of 97
 
 
 
 
5. IMMUNITY TEST 
 
5.1 GENERAL DESCRIPTION 
 
Tests 
Standard No. 
TEST SPECIFICATION 
Level 
Test Mode 
Test Ports 
Perform. 
Criteria 
Remark 
1. Input immunity (S1)
---- 
---- 
---- 
N/A 
2. Immunity against 
  RFI voltages (S2a) 
---- ---- 
---- 
PASS 
3. Immunity against 
  RFI currents (S2b) 
---- ---- 
---- 
N/A 
4. Immunity against 
  radiated RFI (S3)(S6)
---- ---- 
---- 
PASS 
(S3) 
5. Screening 
effectiveness (S4) 
---- ---- 
---- 
N/A 
6. Immunity to 
electromagnetic fields 
Keyed Carrier (S5) 
IEC 61000-4-3 
900 MHz  3V/m(rms) 
Duty Cycle:1/8 
  Modulation: Pulse 217 Hz
Enclosure A PASS 
  8KV air discharge 
  4KV contact discharge 
Direct Mode 
PASS 
7. ESD 
IEC 61000-4-2   
 
 4KV HCP discharge 
  4KV VCP discharge 
Indirect Mode 
PASS 
 1.0KV(peak) 
 5/50ns Tr/Th 
  5KHz Repetition Freq. 
Power Supply 
Port  
B PASS 
8. EFT/Burst 
IEC 61000-4-4 
 0.5 KV(peak) 
 5/50ns Tr/Th 
  5KHz Repetition Freq. 
CTL/Signal 
 Data Line 
Port 
B PASS 
* Remark: 
N/A :  denotes test is not applicable in this Test Report 
(1) :  The EUT is a battery operating device and no any other cable connection to PC device. 
(2) :  Applicable only to cables which according to the manufacturer’s specification supports 
communication on cables lengths greater than 3 m. 
(3) :  Applicable only to equipment containing devices susceptible to magnetic fields 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 63 of 97
 
 
 
5.2 GENERAL PERFORMANCE CRITERIA
 
 
             
   
Criterion A
 
The equipment shall continue to operate as intended without operator 
intervention. No degradation of performance or loss of function is allowed below 
a performance level specified by the manufacturer when the equipment is used 
as intended. The performance level may be replaced by a permissible loss of 
performance. 
If the minimum performance level or the permissible performance loss is not 
specified by the manufacturer, then either of these may be derived from the 
product description and documentation, and by what the user product 
description and documentation, and by what the user may reasonably expect 
from the equipment if used as intended. 
Criterion B
 
After the test, the equipment shall continue to operate as intended without 
operator  
Intervention. No degradation of performance or loss of function is allowed, after 
the application of the phenomenon below a performance level specified by the 
manufacturer, when the equipment is used as intended. The performance level 
may be replaced by a permissible loss of performance. 
During the test, degradation of performance is allowed. However, no change of 
operating state if stored data allowed to persist after the test. If the minimum 
performance level (or the permissible performance loss ) is not specified by the 
manufacturer, then either of these may be derived from the product description 
and documentation, and by what the user may reasonably expect from the 
equipment if used as intended. 
Criterion C
 
Loss of function is allowed, provided the function is self-recoverable, or can be 
restored by the operation of the controls by the user in accordance with the 
manufacturer’s instructions. 
Functions, and/or information stored in non-volatile memory, or protected by a 
battery backup, shall not be lost. 
 
5.3 TEST SETUP 
The EUT tested system was configured as the statements of 4.1.7  Unless otherwise a special 
operating condition is specified in the follows during the testing. 
  
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 64 of 97
 
 
 
5.4 IMMUNITY AGAINST RFI VOLTAGES (S2a) 
 
5.4.1 TEST LIMIT 
 
 
Limits of immunity to RF voltages of AUX IN and output terminals 
Frequency 
MHz 
Level 
dB (uV) (e.m.f.) 
0.15 to 1.6 
80 – 90
a
 
1.6 to 20 
90 – 120
a
 
20 to 100 
120 
100 to 150 
120 – 110
b
 
a
 Increasing linearly with the logarithm of the frequency
 
b
 Decreasing linearly with the logarithm of the frequency
 
 
Limits of immunity to RF voltages of mains, loudspeaker and headphone terminals 
Frequency 
MHz 
Level 
dB (uV) (e.m.f.) 
0.15 to 30 
130 
30 to 100 
120 
100 to 150 
120 – 110
a
 
a
 Decreasing linearly with the logarithm of the frequency
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 97
Display

Click on the first or last page to see other SB 300 (serv.man6) service manuals if exist.