Report No.: NEI-EMC-1-1009C113 Page 41 of 97
4.3.8 TEST RESULTS
E.U.T :
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature :
---
Relative Humidity :
---
Pressure :
---
Test Voltage :
---
Test Mode :
“N/A” denotes test is not applicable in this Test Report
Remark:
(1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak
Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW
=120KHz, Swp. Time = 0.3 sec./MHz。
=120KHz, Swp. Time = 0.3 sec./MHz。
(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes
that the Peak reading compliance with the QP Limits and then QP Mode measurement
didn‘t perform。
didn‘t perform。
(3) Measuring frequency range from 30MHz to 1000MHz。
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
in table。
(5) “N/A” denotes test is not applicable in this Test Report
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 42 of 97
4.4 HARMONICS CURRENT MEASUREMENT
4.4.1 LIMITS OF HARMONICS CURRENT MEASUREMENT
IEC 555-2
Table - I
Table - II
Equipment
Category
Harmonic
Order
n
Max. permissible
harmonic current
harmonic current
(in Ampers)
Equipment
Category
Harmonic
Order
n
Max. permissible
harmonic current
harmonic current
(in Ampers)
odd harmonics
odd harmonics
3 2.30 3 0.80
5 1.14 5 0.60
7 0.77 7 0.45
5 1.14 5 0.60
7 0.77 7 0.45
Non 9
0.40 TV
9
0.30
Portable 11
0.33 Receivers
11 0.17
Tools 13
0.21
13 0.12
or
15
≤n≤39 0.15.15/n
15
≤n≤39 0.10.15/n
TV
even harmonics
even harmonics
Receivers 2
1.08
2 0.30
4 0.43 4 0.15
6 0.30
6 0.30
8
≤n≤40 0.23.8/n
DC
0.05
EN 61000-3-2/IEC 61000-3-2
Equipment
Category
Max. permissible
harmonic current
harmonic current
(in Ampers)
Equipment
Category
Harmonic
Order
n
Max. permissible
harmonic current
harmonic current
(in A) (mA/w)
3
2.30
3.4
Same as Limits
5
1.14
1.9
Class A
Specified in
Class D
7
0.77
1.0
4-2.1,
Table
-
I, 9
0.40
0.5
but only odd
11
0.33
0.35
harmonics
required
13
≤n≤39
see Table I
3.85/n
only odd harmonics required
4.4.2 MEASUREMENT INSTRUMENTS LIST
Item Kind of Equipment
Manufacturer
Type No.
Serial No.
Calibrated until
1 Harmonic
&
Flicker
California
PACS-1
72344
May.27.2011
2 Power
Source
California
3001iX
56309
May.27.2011
Remark: ” N/A” denotes No Model Name / Serial No. and No Calibration specified.
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 43 of 97
4.4.3 TEST PROCEDURE
a. The EUT was placed on the top of a wooden table 0.8 meters above the ground and operated
to produce the maximum harmonic components under normal operating conditions.
b. The classification of EUT is according to section 5 of EN 61000-3-2: 2006.The EUT is
classified as follows:
Class A: Balanced three-phase equipment, Household appliances excluding equipment as
Class D, Tools excluding portable tools, Dimmers for incandescent lamps, audio
equipment, equipment not specified in one of the three other classes.
equipment, equipment not specified in one of the three other classes.
Class B: Portable tools. Arc welding equipment which is not professional equipment.
Class C: Lighting equipment.
Class D: Equipment having a specified power less than or equal to 600 W of the following
Class C: Lighting equipment.
Class D: Equipment having a specified power less than or equal to 600 W of the following
types: Personal computers and personal computer monitors and television
receivers.
receivers.
c. The correspondent test program of test instrument to measure the current harmonics
emanated from EUT is chosen. The measure time shall be not less than the time necessary for
the EUT to be exercised.
the EUT to be exercised.
d. For the actual test configuration, please refer to the related Item –Block Diagram of system
tested (please refer to 3.3).
4.4.4 DEVIATION FROM TEST STANDARD
No deviation
4.4.5 TEST SETUP
EUT
To AC Mains
Power Supply
Non-Metallic Table
Power Analyzer &
Power Source
Voltage Supply
To EUT
4.4.6 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 4.1.7 Unless otherwise a special
operating condition is specified in the follows during the testing.
The EUT tested system was configured as the statements of 4.1.7 Unless otherwise a special
operating condition is specified in the follows during the testing.
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 44 of 97
4.4.7 TEST RESULTS
Harmonics – Class-A per Ed. 3.2(Run time)
EUT:
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature:
23℃
Relative Humidity: 47%
Pressure: 1010
hPa
Test Power :
AC 230V/50Hz
Test Mode :
AUX IN / CNTR, TianBao
Current & voltage waveforms
-0.6
-0.4
-0.2
0.0
0.2
0.4
0.6
-300
-200
-100
0
100
200
300
Current (Amps)
Voltage (Volts)
Limits
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
Test result: Pass Worst harmonic was #19 with 18.02% of the limit.