JBL SB 300 (serv.man6) EMC - CB Certificate ▷ View online

Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 25 of 97
 
 
 
E.U.T : 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature : 
25°C 
Relative Humidity : 54 % 
Pressure : 
1010 hPa 
Test Voltage : 
AC 230V/50Hz 
Test Mode : 
Optical IN / CNTR, TianBao 
 
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
1.03
Line
42.62
*
56.00
46.00
-13.38
(QP)
1.66
Line
46.52
38.56
56.00
46.00
-7.44
(AV)
2.02
Line
45.92
34.17
56.00
46.00
-10.08
(QP)
2.45
Line
46.52
35.69
56.00
46.00
-9.48
(QP)
14.77
Line
54.32
36.92
60.00
50.00
-5.68
(QP)
24.58
Line
48.38
46.48
60.00
50.00
-3.52
(AV)
Measured(dBuV)
Limits(dBuV)
Note
 
 
Remark
 
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with 
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。 
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If  the QP 
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT 
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of 
Interference Voltage Measured。 
(3) Measuring frequency range from 150KHz to 30MHz。 
 
 
 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 26 of 97
 
 
 
E.U.T : 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature : 
25°C 
Relative Humidity : 54 % 
Pressure : 
1010 hPa 
Test Voltage : 
AC 230V/50Hz 
Test Mode : 
Optical IN / CNTR, TianBao 
 
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
1.03
Neutral
44.51
33.17
56.00
46.00
-11.49
(QP)
1.58
Neutral
47.33
32.61
56.00
46.00
-8.67
(QP)
1.66
Neutral
47.59
33.14
56.00
46.00
-8.41
(QP)
2.30
Neutral
46.81
35.44
56.00
46.00
-9.19
(QP)
14.75
Neutral
53.01
32.96
60.00
50.00
-6.99
(QP)
24.58
Neutral
48.90
46.58
60.00
50.00
-3.42
(AV)
Measured(dBuV)
Limits(dBuV)
Note
 
 
Remark
 
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with 
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。 
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If  the QP 
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT 
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of 
Interference Voltage Measured。 
(3) Measuring frequency range from 150KHz to 30MHz。 
 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 27 of 97
 
 
E.U.T : 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature : 
25°C 
Relative Humidity : 54 % 
Pressure : 
1010 hPa 
Test Voltage : 
AC 230V/50Hz 
Test Mode : 
Optical IN / CNTR, HanWei 
 
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
0.17
Line
59.82
37.15
65.16
55.16
-5.34
(QP)
0.20
Line
55.23
34.16
63.69
53.69
-8.46
(QP)
0.77
Line
43.04
*
56.00
46.00
-12.96
(QP)
1.53
Line
36.42
*
56.00
46.00
-19.58
(QP)
2.31
Line
36.36
*
56.00
46.00
-19.64
(QP)
27.65
Line
44.08
*
60.00
50.00
-15.92
(QP)
Measured(dBuV)
Limits(dBuV)
Note
 
 
Remark
 
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with 
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。 
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If  the QP 
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT 
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of 
Interference Voltage Measured。 
(3) Measuring frequency range from 150KHz to 30MHz。 
 
 
 
 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 28 of 97
 
 
E.U.T : 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature : 
25°C 
Relative Humidity : 54 % 
Pressure : 
1010 hPa 
Test Voltage : 
AC 230V/50Hz 
Test Mode : 
Optical IN / CNTR, HanWei 
 
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
0.17
Neutral
59.78
36.75
65.16
55.16
-5.38
(QP)
0.20
Neutral
55.64
33.62
63.53
53.53
-7.89
(QP)
0.23
Neutral
51.38
32.43
62.31
52.31
-10.93
(QP)
0.77
Neutral
42.89
*
56.00
46.00
-13.11
(QP)
1.54
Neutral
34.73
*
56.00
46.00
-21.27
(QP)
24.58
Neutral
44.80
*
60.00
50.00
-15.20
(QP)
Measured(dBuV)
Limits(dBuV)
Note
 
 
Remark
 
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with 
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。 
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If  the QP 
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT 
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of 
Interference Voltage Measured。 
(3) Measuring frequency range from 150KHz to 30MHz。 
 
 