Report No.: NEI-EMC-1-1009C113 Page 13 of 97
3.4 DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.
support units. The following support units or accessories were used to form a representative test
configuration during the tests.
Item
Equipment
Mfr/Brand
Model/Type No.
FCC ID
Series No.
Note
E-1-1
E-1-2
E-1-2
Powered soundbar
with powered
woofer
JBL SB300
Verification
N/A EUT
E-2 DVD
Player Pioneer DV-400
Verification GFKD000248CN
Item
Shielded Type
Ferrite Core
Length
Note
C-1
NO NO 1.8M
C-2
NO NO 0.6M
Note:
(1)
The support equipment was authorized by Declaration of Confirmation.
(2)
For detachable type I/O cable should be specified the length in m in『Length』column.
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 14 of 97
4. EMC EMISSION TEST
4.1 MAINS TERMINAL DISTURBANCE VOLTAGE MEASUREMENT
4.1.1 LIMITS OF DISTURBANCE VOLTAGE AT THE MAINS TERMINALS
Limit values (dB(μV) )
Equipment type
Frequency Range
MHz
Quasi-peak
Average
0.15 - 0.5
66-56
a
56-46
a
0.5 - 5
56
46
Television and sound
receivers and
associated equipment
5 - 30
60
50
a
Decreasing linearly with the logarithm of the frequency.
Note:
(1) The tighter limit applies at the band edges.
(2) The limit of " * " marked band means the limitation decreases linearly with the
logarithm of the frequency in the range.
4.1.2 MEASUREMENT INSTRUMENTS LIST
Item Kind of Equipment
Manufacturer
Type No.
Serial No.
Calibrated until
1 LISN
EMCO 3816/2
00052765
May.26.2011
2 LISN
R&S
ENV216 100087 May.26.2011
3 Test
Cable
N/A
C_17
N/A
Mar.31.2011
4
EMI TEST
RECEIVER
R&S ESCS30
8333641017
May.27.2011
5 50Ω Terminator
SHX
TF2-3G-A
08122902
May.26.2011
Remark: ” N/A” denotes No Model Name, Serial No. or No Calibration specified.
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 15 of 97
4.1.3 TEST PROCEDURE
a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
to the power mains through a line impedance stabilization network (LISN). All other support
equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
impedance for the measuring instrument.
b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
and forth in the center forming a bundle 30 to 40 cm long.
c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
cable may be terminated, if required, using the correct terminating impedance. The overall
length shall not exceed 1 m.
d. LISN at least 80 cm from nearest part of EUT chassis.
e. For the actual test configuration, please refer to the related Item –Block Diagram of system
tested (please refer to 3.3).
4.1.4 DEVIATION FROM TEST STANDARD
No deviation
4.1.5 TEST SETUP
LISN
EUT
Test Receiver
40 cm
80 cm
Horizontal Reference Ground Plane
Vertical Reference Ground Plane
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 16 of 97
4.1.6 BLOCK DIAGRAM OF TEST SETUP
EUT-1
L.I.S.N.#1
Test Receiver
DVD
AC
Mains
Audio Cable
EUT-2
L.I.S.N.#2
AC
Mains
Remote
Fiber Cable
4.1.7 EUT OPERATING CONDITIONS
The EUT exercise program used during radiated and/or conducted emission measurement was
designed to exercise the various system components in a manner similar to a typical use. The
standard test signals and output signal as following:
1. Input signal: A sinusoidal signal at 1kHz.
2. Output signal: The audio output signal shall be adjusted by the volume control to be 1/8 of the
rated output power for each output
This operating condition was tested and used to collect the included data.
The EUT exercise program used during radiated and/or conducted emission measurement was
designed to exercise the various system components in a manner similar to a typical use. The
standard test signals and output signal as following:
1. Input signal: A sinusoidal signal at 1kHz.
2. Output signal: The audio output signal shall be adjusted by the volume control to be 1/8 of the
rated output power for each output
This operating condition was tested and used to collect the included data.