Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 21 of 97
 
 
E.U.T : 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature : 
25°C 
Relative Humidity : 54 % 
Pressure : 
1010 hPa 
Test Voltage : 
AC 230V/50Hz 
Test Mode : 
AUX IN / CNTR, TianBao 
 
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
1.66
Line
48.11
38.16
56.00
46.00
-7.84
(AV)
1.75
Line
46.36
35.16
56.00
46.00
-9.64
(QP)
2.42
Line
45.73
35.39
56.00
46.00
-10.27
(QP)
3.18
Line
45.32
33.42
56.00
46.00
-10.68
(QP)
12.09
Line
48.31
37.55
60.00
50.00
-11.69
(QP)
14.73
Line
54.88
36.82
60.00
50.00
-5.12
(QP)
Measured(dBuV)
Limits(dBuV)
Note
 
 
Remark
 
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with 
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。 
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If  the QP 
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT 
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of 
Interference Voltage Measured。 
(3) Measuring frequency range from 150KHz to 30MHz。 
 
 
 
 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 22 of 97
 
 
E.U.T : 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature : 
25°C 
Relative Humidity : 54 % 
Pressure : 
1010 hPa 
Test Voltage : 
AC 230V/50Hz 
Test Mode : 
AUX IN / CNTR, TianBao 
 
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
1.58
Neutral
48.64
38.11
56.00
46.00
-7.36
(QP)
1.66
Neutral
48.28
37.24
56.00
46.00
-7.72
(QP)
2.00
Neutral
46.71
33.33
56.00
46.00
-9.29
(QP)
2.42
Neutral
46.52
35.44
56.00
46.00
-9.48
(QP)
12.17
Neutral
49.08
37.61
60.00
50.00
-10.92
(QP)
14.69
Neutral
52.23
35.76
60.00
50.00
-7.77
(QP)
Measured(dBuV)
Limits(dBuV)
Note
 
 
Remark
 
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with 
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。 
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If  the QP 
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT 
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of 
Interference Voltage Measured。 
(3) Measuring frequency range from 150KHz to 30MHz。 
 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 23 of 97
 
 
E.U.T : 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature : 
25°C 
Relative Humidity : 54 % 
Pressure : 
1010 hPa 
Test Voltage : 
AC 230V/50Hz 
Test Mode : 
AUX IN / CNTR, HanWei 
 
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
0.17
Line
60.68
38.35
65.16
55.16
-4.48
(QP)
0.20
Line
56.32
35.86
63.69
53.69
-7.37
(QP)
0.23
Line
52.84
32.57
62.31
52.31
-9.47
(QP)
0.27
Line
49.77
31.66
61.24
51.24
-11.47
(QP)
0.52
Line
47.47
36.55
56.00
46.00
-8.53
(QP)
18.85
Line
46.27
*
60.00
50.00
-13.73
(QP)
Measured(dBuV)
Limits(dBuV)
Note
 
 
Remark
 
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with 
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。 
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If  the QP 
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT 
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of 
Interference Voltage Measured。 
(3) Measuring frequency range from 150KHz to 30MHz。 
 
 
 
 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 24 of 97
 
 
E.U.T : 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature : 
25°C 
Relative Humidity : 54 % 
Pressure : 
1010 hPa 
Test Voltage : 
AC 230V/50Hz 
Test Mode : 
AUX IN / CNTR, HanWei 
 
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
0.17
Neutral
59.99
35.35
65.16
55.16
-5.17
(QP)
0.20
Neutral
55.08
31.42
63.53
53.53
-8.45
(QP)
0.23
Neutral
50.92
32.03
62.31
52.31
-11.39
(QP)
0.53
Neutral
45.66
33.99
56.00
46.00
-10.34
(QP)
1.67
Neutral
44.61
34.74
56.00
46.00
-11.26
(AV)
18.96
Neutral
46.51
*
60.00
50.00
-13.49
(QP)
Measured(dBuV)
Limits(dBuV)
Note
 
 
Remark
 
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with 
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。 
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If  the QP 
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT 
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,