Report No.: NEI-EMC-1-1009C113 Page 37 of 97
4.3 RADIATED DISTURBANCE MEASUREMENT
4.3.1 LIMITS OF RADIATED DISTURBANCE MEASUREMENT (at 3 m distance)
Frequency
Limit values(dB(μV/m))
Equipment type
Source
MHz
Quasi-peak
Local oscillator
≤1000
Fundamental 57
a
30 to 300
Harmonics
52
300 to 1000
Harmonics
56
Other
30 to 230
40
Television receivers,
video recorders and PC
tuner cards
230 to 1000
47
Other
30 to 230
40
230 to 1000
47
Television and sound
receivers for broadcast
satellite transmissions
(except outdoor units).
Infrared remote control
units and
Infrared headphone
systems
Local oscillator
≤1000
Fundamental 60
30 to 300
Harmonics
52
300 to 1000
Harmonics
56
Other
30 to 230
40
Frequency modulation
sound receiver and PC
tuner cards
230 to 1000
47
a
In Japan: 57 dB(μV/m) is relaxed to 66 dB(μV/m) for operating channels <300
MHz and to 70 dB(μV/m) for operating channels >300 MHz.
Notes:
(1) For car radio receivers and for LW, MW and SW AM broadcast receivers no radiation
limits apply.
LIMITS OF RADIATED POWER OF TUNER UNITS OF DIRECT TO HOME SATELLITE
RECEINERS
RECEINERS
Equipment type
Source
Frequency
MHz
Limit values
dB(pW)
1 to 3
Fundamental 57
Television and sound
receivers for broadcast
satellite transmissions:
tuner units
Local oscillator
1 to 3
Harmonics 57
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 38 of 97
LIMITS OF RADIATED POWER OF OUTDOOR UNITS OF DIRECT TO HOME STELLITE
RECEIVERS
RECEIVERS
Equipment type
Source
Frequency
GHz
Limit values
dB(pW)
Outdoor units of direct
to home satellite
receivers
to home satellite
receivers
Local oscillator
leakage radiated
from the antenna
within ±7° of the
main beam axis
leakage radiated
from the antenna
within ±7° of the
main beam axis
a
0.9 to 18
Fundamental 30
Equivalent radiated
power from outdoor
unit including the
local oscillator
leakage
b
1 to 2.5
2.5 to 18
43
57
57
a
The direct measurement is carried out according to 5.9. When the reflector of the
parabolic antenna cannot be removed, the indirect measurement according to 5.8 is
carried out. In that case, the antenna gain shall be taken into account.
carried out. In that case, the antenna gain shall be taken into account.
b
Measurement of the equivalent radiated power shall be in accordance with 5.8. No
requirements within ±7° off the main beam axis of the antenna.
4.3.2 MEASUREMENT INSTRUMENTS LIST
Item Kind of Equipment
Manufacturer
Type No.
Serial No.
Calibrated until
1
Antenna
Schwarzbeck
VULB 9160
9160-3060
Jun .30.2011
2 Amplifier
HP
8447D
1937A02847
May.26.2011
3 Test
Receiver
R&S
ESCI
100382 May.26.2011
4 Test
Cable
N/A
C-05_OS01
N/A
Jul.08.2011
5 Controller
CT
SC100 N/A
N/A
Remark: ” N/A” denotes No Model Name / Serial No. and No Calibration specified.
Receiver Parameter
Setting
Attenuation Auto
Start ~ Stop Frequency
9kHz~150kHz / RB 200Hz for QP
Start ~ Stop Frequency
150kHz~30MHz / RB 9kHz for QP
Start ~ Stop Frequency
30MHz~1000MHz / RB 120kHz for QP
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 39 of 97
4.3.3 TEST PROCEDURE
a. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz.
For frequencies above 1GHz, any suitable measuring distance may be used.
b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter
semi-anechoic chamber. The table was rotated 360 degrees to determine the position of the
highest radiation.
highest radiation.
c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test
antenna shall vary between 1 m to 4 m. Both horizontal and vertical polarizations of the
antenna are set to make the measurement.
antenna are set to make the measurement.
d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector
mode pre-scanning the measurement frequency range. Significant peaks are then marked and
then Quasi Peak detector mode re-measured.
then Quasi Peak detector mode re-measured.
e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
performed.
performed.
f. For the actual test configuration, please refer to the related Item –Block Diagram of system
tested (please refer to 3.3).
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz
for Quasi-peak detection (QP) at frequency below 1GHz.
4.3.4 DEVIATION FROM TEST STANDARD
No deviation
No deviation
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 40 of 97
4.3.5 TEST SETUP-SEMI-ANECHOIC CHAMBER
4.3.6 BLOCK DIAGRAM OF TEST SETUP-OS
N/A
4.3.7 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 4.1.7 Unless otherwise a special
operating condition is specified in the follows during the testing.
The EUT tested system was configured as the statements of 4.1.7 Unless otherwise a special
operating condition is specified in the follows during the testing.
Click on the first or last page to see other SB 300 (serv.man6) service manuals if exist.