Report No.: NEI-EMC-1-1009C113                                                                                                          Page 17 of 97
 
 
4.1.8 TEST RESULTS 
 
E.U.T : 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature : 
25°C 
Relative Humidity : 54 % 
Pressure : 
1010 hPa 
Test Voltage : 
AC 230V/50Hz 
Test Mode : 
AUX IN / Woofer, TianBao 
 
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
0.33
Line
44.11
*
59.35
49.35
-15.24
(QP)
0.41
Line
50.44
38.57
57.57
47.57
-7.13
(QP)
1.13
Line
43.46
*
56.00
46.00
-12.54
(QP)
1.68
Line
45.52
39.43
56.00
46.00
-6.57
(AV)
2.17
Line
43.28
*
56.00
46.00
-12.72
(QP)
27.65
Line
42.95
*
60.00
50.00
-17.05
(QP)
Measured(dBuV)
Limits(dBuV)
Note
 
 
Remark
 
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with 
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。 
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If  the QP 
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT 
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of 
Interference Voltage Measured。 
(3) Measuring frequency range from 150KHz to 30MHz。 
 
 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 18 of 97
 
 
E.U.T : 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature : 
25°C 
Relative Humidity : 54 % 
Pressure : 
1010 hPa 
Test Voltage : 
AC 230V/50Hz 
Test Mode : 
AUX IN / Woofer, TianBao 
 
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
0.41
Neutral
51.52
40.72
57.65
47.65
-6.13
(QP)
1.01
Neutral
44.73
39.95
56.00
46.00
-6.05
(AV)
1.61
Neutral
45.07
40.97
56.00
46.00
-5.03
(AV)
3.23
Neutral
44.24
39.32
56.00
46.00
-6.68
(AV)
24.58
Neutral
46.31
*
60.00
50.00
-13.69
(QP)
27.65
Neutral
44.00
*
60.00
50.00
-16.00
(QP)
Measured(dBuV)
Limits(dBuV)
Note
 
 
Remark
 
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with 
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。 
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If  the QP 
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT 
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of 
Interference Voltage Measured。 
(3) Measuring frequency range from 150KHz to 30MHz。 
 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 19 of 97
 
 
E.U.T : 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature : 
25°C 
Relative Humidity : 54 % 
Pressure : 
1010 hPa 
Test Voltage : 
AC 230V/50Hz 
Test Mode : 
AUX IN / Woofer, HanWei 
 
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
0.16
Line
37.00
*
65.36
55.36
-28.36
(QP)
0.18
Line
36.58
*
64.39
54.39
-27.81
(QP)
0.53
Line
37.05
*
56.00
46.00
-18.95
(QP)
12.29
Line
38.66
*
60.00
50.00
-21.34
(QP)
24.58
Line
37.70
*
60.00
50.00
-22.30
(QP)
27.65
Line
37.05
*
60.00
50.00
-22.95
(QP)
Measured(dBuV)
Limits(dBuV)
Note
 
 
Remark
 
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with 
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。 
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If  the QP 
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT 
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of 
Interference Voltage Measured。 
(3) Measuring frequency range from 150KHz to 30MHz。 
 
 
 
 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 20 of 97
 
 
E.U.T : 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature : 
25°C 
Relative Humidity : 54 % 
Pressure : 
1010 hPa 
Test Voltage : 
AC 230V/50Hz 
Test Mode : 
AUX IN / Woofer, HanWei 
 
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
0.16
Neutral
38.66
*
65.36
55.36
-26.70
(QP)
0.18
Neutral
37.40
*
64.39
54.39
-26.99
(QP)
0.33
Neutral
38.20
*
59.35
49.35
-21.15
(QP)
12.29
Neutral
41.95
*
60.00
50.00
-18.05
(QP)
24.58
Neutral
46.11
*
60.00
50.00
-13.89
(QP)
27.65
Neutral
39.05
*
60.00
50.00
-20.95
(QP)
Measured(dBuV)
Limits(dBuV)
Note
 
 
Remark
 
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with 
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。 
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If  the QP 
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT 
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of 