4.1.8 TEST RESULTS
E.U.T :
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature :
25°C
Relative Humidity : 54 %
Pressure :
1010 hPa
Test Voltage :
AC 230V/50Hz
Test Mode :
AUX IN / Woofer, TianBao
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
0.33
Line
44.11
*
59.35
49.35
-15.24
(QP)
0.41
Line
50.44
38.57
57.57
47.57
-7.13
(QP)
1.13
Line
43.46
*
56.00
46.00
-12.54
(QP)
1.68
Line
45.52
39.43
56.00
46.00
-6.57
(AV)
2.17
Line
43.28
*
56.00
46.00
-12.72
(QP)
27.65
Line
42.95
*
60.00
50.00
-17.05
(QP)
Measured(dBuV)
Limits(dBuV)
Note
Remark
:
:
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of
Interference Voltage Measured。
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of
Interference Voltage Measured。
(3) Measuring frequency range from 150KHz to 30MHz。
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 18 of 97
E.U.T :
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature :
25°C
Relative Humidity : 54 %
Pressure :
1010 hPa
Test Voltage :
AC 230V/50Hz
Test Mode :
AUX IN / Woofer, TianBao
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
0.41
Neutral
51.52
40.72
57.65
47.65
-6.13
(QP)
1.01
Neutral
44.73
39.95
56.00
46.00
-6.05
(AV)
1.61
Neutral
45.07
40.97
56.00
46.00
-5.03
(AV)
3.23
Neutral
44.24
39.32
56.00
46.00
-6.68
(AV)
24.58
Neutral
46.31
*
60.00
50.00
-13.69
(QP)
27.65
Neutral
44.00
*
60.00
50.00
-16.00
(QP)
Measured(dBuV)
Limits(dBuV)
Note
Remark
:
:
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of
Interference Voltage Measured。
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of
Interference Voltage Measured。
(3) Measuring frequency range from 150KHz to 30MHz。
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 19 of 97
E.U.T :
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature :
25°C
Relative Humidity : 54 %
Pressure :
1010 hPa
Test Voltage :
AC 230V/50Hz
Test Mode :
AUX IN / Woofer, HanWei
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
0.16
Line
37.00
*
65.36
55.36
-28.36
(QP)
0.18
Line
36.58
*
64.39
54.39
-27.81
(QP)
0.53
Line
37.05
*
56.00
46.00
-18.95
(QP)
12.29
Line
38.66
*
60.00
50.00
-21.34
(QP)
24.58
Line
37.70
*
60.00
50.00
-22.30
(QP)
27.65
Line
37.05
*
60.00
50.00
-22.95
(QP)
Measured(dBuV)
Limits(dBuV)
Note
Remark
:
:
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of
Interference Voltage Measured。
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of
Interference Voltage Measured。
(3) Measuring frequency range from 150KHz to 30MHz。
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 20 of 97
E.U.T :
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature :
25°C
Relative Humidity : 54 %
Pressure :
1010 hPa
Test Voltage :
AC 230V/50Hz
Test Mode :
AUX IN / Woofer, HanWei
Freq.
Terminal
Margin
(MHz)
L/N
QP-Mode
AV-Mode
QP-Mode
AV-Mode
(dB)
0.16
Neutral
38.66
*
65.36
55.36
-26.70
(QP)
0.18
Neutral
37.40
*
64.39
54.39
-26.99
(QP)
0.33
Neutral
38.20
*
59.35
49.35
-21.15
(QP)
12.29
Neutral
41.95
*
60.00
50.00
-18.05
(QP)
24.58
Neutral
46.11
*
60.00
50.00
-13.89
(QP)
27.65
Neutral
39.05
*
60.00
50.00
-20.95
(QP)
Measured(dBuV)
Limits(dBuV)
Note
Remark
:
:
(1) Reading in which marked as QP means measurements by using are Quasi-Peak Mode with
Detector BW=9KHz;SPA setting in RBW=10KHz,VBW =10KHz, Swp. Time = 0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。
Reading in which marked as AV means measurements by using are Average Mode with
instrument setting in RBW=10KHz,VBW=10KHz, Swp. Time =0.3 sec./MHz。
(2) All readings are QP Mode value unless otherwise stated AVG in column of『Note』. If the QP
Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of
Interference Voltage Measured。
shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
but AVG Mode didn‘t perform。In this case, a “ * ” marked in AVG Mode column of
Interference Voltage Measured。
(3) Measuring frequency range from 150KHz to 30MHz。
Click on the first or last page to see other SB 300 (serv.man6) service manuals if exist.