JBL SB 300 (serv.man6) EMC - CB Certificate ▷ View online
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 29 of 97
4.2 DISTURBANCE POWER MEASUREMENT
4.2.1 LIMITS OF DISTURBANCE POWER
Limit values
dB(μV) 75Ω
Equipment type
Frequency
MHz
Quasi-peak
Average
Associated equipment
(video recorders excluded)
30 to 300
45 to 55
a
35 to 45
a
a
Increasing linearly with the frequency.
Notes:
(1). lf the limits for the average detector are met when using the quasi-peak detector,
the limits for the measurements with average detector are considered to be met.
4.2.2 MEASUREMENT INSTRUMENTS LIST
Item Kind of Equipment
Manufacturer
Type No.
Serial No.
Calibrated until
1 Absorbing
Clamp
R&S
MDS-21
3985
Nov.08.2011
2 Test
Cable
N/A
C-04_Clamp
N/A
Jul.06.2011
3 Amplifier
HP
8447D
1937A02847
May.26.2011
4 Attenuator BroadWave
Tech
352-057-006
N/A
Jul.06.2011
5 Test
Receiver
R&S
ESCI
100895 May.26.2011
Remark: ” N/A” denotes No Model Name / Serial No. and No Calibration specified.
4.2.3 TEST PROCEDURE
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter
chamber room. The table was rotated 360 degrees to determine the position of the highest
radiation.
radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted
on the top of a variable-height antenna tower.
c. The antenna is a broadband antenna, and its height is varied from one meter to four meters
above the ground to determine the maximum value of the field strength. Both horizontal and
vertical polarizations of the antenna are set to make the measurement.
vertical polarizations of the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna
was tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0
degrees to 360 degrees to find the maximum reading.
degrees to 360 degrees to find the maximum reading.
e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with
maximum hold mode when the test frequency is below 1 GHz.
f. Mode Optical IN test is not applicable in this Test Report
Note:
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz
for Quasi-peak detection (QP) at frequency below 1GHz.
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 30 of 97
4.2.4 DEVIATION FROM TEST STANDARD
No deviation
No deviation
4.2.5 TEST SETUP-CLAMP
4.2.6 BLOCK DIAGRAM OF TEST SETUP-CLAMP
EUT-1
Test Receiver
DVD
AC
Mains
Audio Cable
EUT-2
AC
Mains
Clamp
Remote
Fiber Cable
4.2.7 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 4.1.7 Unless otherwise a special
operating condition is specified in the follows during the testing.
The EUT tested system was configured as the statements of 4.1.7 Unless otherwise a special
operating condition is specified in the follows during the testing.
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 31 of 97
4.2.8 TEST RESULTS
E.U.T :
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature :
25°C
Relative Humidity :
50 %
Pressure :
1010 hPa
Test Voltage :
AC 230V/50Hz
Test Mode :
AUX IN/ AC Cable Woofer ,TianBao
Freq.
Factor(CF)
Measured(dBuV)
Limits(dBuV)
Safe Margins
(MHz)
QP
AV
(dB)
QP-Mode AV-Mode QP-Mode AV-Mode (dBuV)
Note
30.00
47.37
0.00
-14.44
32.93
-14.44
45.00
35.00
-12.07
36.75
49.55
0.00
-17.26
32.29
-17.26
45.25
35.25
-12.96
101.55 51.21
0.00
-17.70
33.51
-17.70
47.65
37.65
-14.14
111.00 55.44
54.71
-19.13
36.31
35.58
48.00
38.00
- 2.42
AV
135.30 55.09
0.00
-19.04
36.05
-19.04
48.90
38.90
-12.85
233.85 46.20
0.00
-18.81
27.39
-18.81
52.55
42.55
-25.16
Read
(RA)(dBuV)
Remark:
(1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak
Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW
=120KHz, Swp. Time = 0.3 sec./MHz。
=120KHz, Swp. Time = 0.3 sec./MHz。
(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes
that the Peak reading compliance with the QP Limits and then QP Mode measurement
didn‘t perform。
didn‘t perform。
(3) Measuring frequency range from 30MHz to 300MHz。
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
in table。
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 32 of 97
E.U.T :
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature :
25°C
Relative Humidity :
50 %
Pressure :
1010 hPa
Test Voltage :
AC 230V/50Hz
Test Mode :
AUX IN/ AC Cable Woofer ,HanWei
Freq.
Factor(CF)
Measured(dBuV)
Limits(dBuV)
Safe Margins
(MHz)
QP
AV
(dB)
QP-Mode AV-Mode QP-Mode AV-Mode (dBuV)
Note
30.00
51.16
38.54
-14.44
36.72
24.10
45.00
35.00
- 8.28
71.17
54.90
39.21
-18.59
36.31
20.62
46.52
36.52
-10.21
86.03
56.24
49.28
-18.45
37.79
30.83
47.08
37.08
- 6.25
AV
92.10
55.48
40.52
-18.14
37.34
22.38
47.30
37.30
- 9.96
111.00
55.44
52.52
-19.13
36.31
33.39
48.00
38.00
- 4.61
AV
135.30
56.31
54.44
-19.04
37.27
35.40
48.90
38.90
- 3.50
AV
Read
(RA)(dBuV)
Remark:
(1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak
Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW
=120KHz, Swp. Time = 0.3 sec./MHz。
=120KHz, Swp. Time = 0.3 sec./MHz。
(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes
that the Peak reading compliance with the QP Limits and then QP Mode measurement
didn‘t perform。
didn‘t perform。
(3) Measuring frequency range from 30MHz to 300MHz。
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
in table。