JBL SB 300 (serv.man6) EMC - CB Certificate ▷ View online
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 33 of 97
E.U.T :
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature :
25°C
Relative Humidity :
50 %
Pressure :
1010 hPa
Test Voltage :
AC 230V/50Hz
Test Mode :
AUX IN/ AC Cable CNTR ,TianBao
Freq.
Factor(CF)
Measured(dBuV)
Limits(dBuV)
Safe Margins
(MHz)
QP
AV
(dB)
QP-Mode AV-Mode QP-Mode AV-Mode (dBuV)
Note
30.00
49.07
42.15
-14.44
34.63
27.71
45.00
35.00
- 7.29
AV
43.50
55.20
48.65
-17.30
37.90
31.35
45.50
35.50
- 4.15
AV
70.50
51.40
0.00
-18.58
32.82
-18.58
46.50
36.50
-13.68
86.03
59.62
48.20
-18.45
41.17
29.75
47.08
37.08
- 5.91
107.62 55.91
47.23
-18.75
37.16
28.48
47.87
37.87
- 9.39
AV
196.72 52.14
0.00
-19.58
32.56
-19.58
51.17
41.17
-18.61
Read
(RA)(dBuV)
Remark:
(1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak
Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW
=120KHz, Swp. Time = 0.3 sec./MHz。
=120KHz, Swp. Time = 0.3 sec./MHz。
(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes
that the Peak reading compliance with the QP Limits and then QP Mode measurement
didn‘t perform。
didn‘t perform。
(3) Measuring frequency range from 30MHz to 300MHz。
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
in table。
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 34 of 97
E.U.T :
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature :
25°C
Relative Humidity :
50 %
Pressure :
1010 hPa
Test Voltage :
AC 230V/50Hz
Test Mode :
AUX IN/ AC Cable CNTR ,HanWei
Freq.
Factor(CF)
Measured(dBuV)
Limits(dBuV)
Safe Margins
(MHz)
QP
AV
(dB)
QP-Mode AV-Mode QP-Mode AV-Mode (dBuV)
Note
36.08
49.52
*
-17.15
32.37
*
45.23
35.23
-12.86
83.33
53.10
*
-18.53
34.57
*
46.98
36.98
-12.41
98.85
54.65
48.98
-17.53
37.12
31.45
47.55
37.55
- 6.10
AV
107.63 56.90
49.75
-18.75
38.15
31.00
47.88
37.88
- 6.88
AV
135.30 53.93
*
-19.04
34.89
*
48.90
38.90
-14.01
184.58 56.05
*
-19.42
36.63
*
50.73
40.73
-14.10
Read
(RA)(dBuV)
Remark:
(1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak
Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW
=120KHz, Swp. Time = 0.3 sec./MHz。
=120KHz, Swp. Time = 0.3 sec./MHz。
(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes
that the Peak reading compliance with the QP Limits and then QP Mode measurement
didn‘t perform。
didn‘t perform。
(3) Measuring frequency range from 30MHz to 300MHz。
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
in table。
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 35 of 97
E.U.T :
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature :
23°C
Relative Humidity :
51 %
Pressure :
1010 hPa
Test Voltage :
AC 230V/50Hz
Test Mode :
AUX IN / AUX IN Cable CNTR, TianBao
Freq.
Factor(CF)
Measured(dBuV)
Limits(dBuV)
Safe Margins
(MHz)
QP
AV
(dB)
QP-Mode AV-Mode QP-Mode AV-Mode (dBuV)
Note
30.00
48.29
39.25
-14.44
33.85
24.81
45.00
35.00
-10.19
AV
36.08
52.73
40.58
-17.15
35.58
23.43
45.23
35.23
- 9.65
43.50
51.51
42.83
-17.30
34.21
25.53
45.50
35.50
- 9.97
AV
89.40
55.66
51.06
-18.34
37.32
32.72
47.20
37.20
- 4.48
AV
95.48
55.22
48.95
-17.84
37.38
31.11
47.43
37.43
- 6.31
AV
101.55 55.39
52.11
-17.70
37.69
34.41
47.65
37.65
- 3.24
AV
Read
(RA)(dBuV)
Remark:
(1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak
Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW
=120KHz, Swp. Time = 0.3 sec./MHz。
=120KHz, Swp. Time = 0.3 sec./MHz。
(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes
that the Peak reading compliance with the QP Limits and then QP Mode measurement
didn‘t perform。
didn‘t perform。
(3) Measuring frequency range from 30MHz to 300MHz。
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
in table。
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 36 of 97
E.U.T :
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature :
23°C
Relative Humidity :
51 %
Pressure :
1010 hPa
Test Voltage :
AC 230V/50Hz
Test Mode :
AUX IN / AUX IN Cable CNTR, HanWei
Freq.
Factor(CF)
Measured(dBuV)
Limits(dBuV)
Safe Margins
(MHz)
QP
AV
(dB)
QP-Mode AV-Mode QP-Mode AV-Mode (dBuV)
Note
70.50
55.05
49.80
-18.58
36.47
31.22
46.50
36.50
- 5.28
AV
77.25
56.18
50.15
-18.62
37.56
31.53
46.75
36.75
- 5.22
AV
83.33
57.55
50.78
-18.53
39.02
32.25
46.98
36.98
- 4.73
AV
89.40
56.07
50.60
-18.34
37.73
32.26
47.20
37.20
- 4.94
AV
101.55 55.46
51.50
-17.70
37.76
33.80
47.65
37.65
- 3.85
AV
107.62 55.87
49.91
-18.75
37.12
31.16
47.87
37.87
- 6.71
AV
Read
(RA)(dBuV)
Remark:
(1) Reading in which marked as QP or Peak means measurements by using are Quasi-Peak
Mode or Peak Mode with Detector BW=120KHz;SPA setting in RBW=120KHz, VBW
=120KHz, Swp. Time = 0.3 sec./MHz。
=120KHz, Swp. Time = 0.3 sec./MHz。
(2) All readings are Peak unless otherwise stated QP in column of『Note』. Peak denotes
that the Peak reading compliance with the QP Limits and then QP Mode measurement
didn‘t perform。
didn‘t perform。
(3) Measuring frequency range from 30MHz to 300MHz。
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
(4) If the peak scan value lower limit more than 20dB, then this signal data does not show
in table。
Click on the first or last page to see other SB 300 (serv.man6) service manuals if exist.