JBL SB 300 (serv.man6) EMC - CB Certificate ▷ View online
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 49 of 97
Voltage Source Verification Data (Run time)
EUT:
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature:
23℃
Relative Humidity: 47%
Pressure: 1010
hPa
Test Power :
AC 230V/50Hz
Highest parameter values during test:
V_RMS (Volts): 229.51
V_RMS (Volts): 229.51
Frequency(Hz): 50.00
I_Peak (Amps): 0.479
I_RMS (Amps):
0.094
I_Fund (Amps): 0.035
Crest Factor:
5.422
Power (Watts):
7.3
Power Factor:
0.367
Test Mode:
AUX IN / CNTR, HanWei
Harm# Harmonics V-rms
Limit V-rms
% of Limit
Status
2
0.127
0.459
27.61
OK
3
0.518
2.066
25.08
OK
4
0.063
0.459
13.66
OK
5
0.085
0.918
9.25
OK
6
0.033
0.459
7.26
OK
7
0.036
0.689
5.21
OK
8
0.017
0.459
3.70
OK
9
0.027
0.459
5.97
OK
10
0.021
0.459
4.68
OK
11
0.038
0.229
16.46
OK
12
0.020
0.229
8.69
OK
13
0.021
0.230
8.98
OK
14
0.009
0.230
4.06
OK
15
0.017
0.230
7.20
OK
16
0.011
0.229
4.70
OK
17
0.019
0.230
8.38
OK
18
0.015
0.230
6.50
OK
19
0.019
0.229
8.35
OK
20
0.015
0.230
6.51
OK
21
0.016
0.230
7.02
OK
22
0.013
0.229
5.56
OK
23
0.015
0.230
6.72
OK
24
0.009
0.229
3.71
OK
25
0.015
0.230
6.46
OK
26
0.007
0.229
3.11
OK
27
0.011
0.229
4.72
OK
28
0.007
0.230
3.01
OK
29
0.008
0.229
3.27
OK
30
0.006
0.229
2.44
OK
31
0.007
0.230
3.07
OK
32
0.006
0.230
2.47
OK
33
0.007
0.229
3.17
OK
34
0.003
0.229
1.32
OK
35
0.005
0.230
2.10
OK
36
0.003
0.229
1.40
OK
37
0.004
0.229
1.85
OK
38
0.005
0.229
2.12
OK
39
0.005
0.229
2.38
OK
40
0.006
0.229
2.54
OK
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 50 of 97
Harmonics – Class-A per Ed. 3.2(Run time)
EUT:
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature:
23℃
Relative Humidity: 47%
Pressure: 1010
hPa
Test Power :
AC 230V/50Hz
Test Mode :
AUX IN / Subwoofer, TianBao
Current & voltage waveforms
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
-300
-200
-100
0
100
200
300
Current (Amps)
Voltage (Volts)
Limits
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
Test result: Pass Worst harmonic was #17 with 34.81% of the limit.
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 51 of 97
Current Test Result Summary (Run time)
EUT:
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature:
23℃
Relative Humidity: 47%
Pressure: 1010
hPa
Test Power :
AC 230V/50Hz
Highest parameter values during test:
V_RMS (Volts): 229.52
V_RMS (Volts): 229.52
Frequency(Hz): 50.00
I_Peak (Amps): 1.147
I_RMS (Amps):
0.250
I_Fund (Amps): 0.094
Crest Factor:
5.383
Power (Watts):
19.7
Power Factor:
0.353
Test Mode :
AUX IN / Subwoofer, TianBao
Harm#Harms(avg)100%Limit%of Limit Harms(max) 150%Limit %of Limit Status
2 0.002 1.080 0.0
0.002 1.620 0.15
Pass
3 0.077 2.300 3.4
0.085 3.450 2.46
Pass
4 0.002 0.430 0.0
0.002 0.645 0.35
Pass
5 0.075 1.140 6.6
0.081 1.710 4.76
Pass
6 0.001 0.300 0.0
0.002 0.450 0.41
Pass
7 0.072 0.770 9.3
0.078 1.155 6.76
Pass
8 0.001 0.230 0.0
0.002 0.345 0.51
Pass
9 0.068 0.400 16.9
0.073 0.600 12.24
Pass
10 0.001 0.184 0.0
0.002 0.276 0.63
Pass
11 0.063 0.330 19.1
0.068 0.495 13.79
Pass
12 0.002 0.153 0.0
0.003 0.230 1.14
Pass
13 0.058 0.210 27.5
0.062 0.315 19.80
Pass
14 0.001 0.131 0.0
0.002 0.197 0.79
Pass
15 0.052 0.150 34.6
0.056 0.225 24.88
Pass
16 0.001 0.115 0.0
0.001 0.173 0.84
Pass
17 0.046 0.132 34.8
0.049 0.199 24.80
Pass
18 0.001 0.102 0.0
0.001 0.153 0.93
Pass
19 0.040 0.118 33.6
0.043 0.178 23.94
Pass
20 0.001 0.092 0.0
0.001 0.138 0.98
Pass
21 0.034 0.107 31.5
0.036 0.161 22.31
Pass
22 0.001 0.084 0.0
0.001 0.125 0.99
Pass
23 0.028 0.098 28.5
0.029 0.147 20.01
Pass
24 0.001 0.077 0.0
0.001 0.115 0.99
Pass
25 0.022 0.090 24.7
0.023 0.135 17.27
Pass
26 0.001 0.071 0.0
0.001 0.106 1.03
Pass
27 0.017 0.083 20.5
0.018 0.125 14.13
Pass
28 0.001 0.066 0.0
0.001 0.099 1.18
Pass
29 0.012 0.078 16.0
0.013 0.116 11.26
Pass
30 0.001 0.061 0.0
0.001 0.092 1.21
Pass
31 0.008 0.073 11.4
0.010 0.109 9.55
Pass
32 0.001 0.058 0.0
0.001 0.086 0.92
Pass
33 0.005 0.068 7.1
0.008 0.102 8.23
Pass
34 0.001 0.054 0.0
0.001 0.081 0.85
Pass
35 0.002 0.064 3.4
0.007 0.096 7.03
Pass
36 0.000 0.051 0.0
0.001 0.077 0.80
Pass
37 0.002 0.061 3.6
0.005 0.091 5.82
Pass
38 0.000 0.048 0.0
0.001 0.073 0.86
Pass
39 0.003 0.058 0.0
0.004 0.087 4.55
Pass
40 0.000 0.046 0.0
0.000 0.069 0.65
Pass
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 52 of 97
Voltage Source Verification Data (Run time)
EUT:
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature:
23℃
Relative Humidity: 47%
Pressure: 1010
hPa
Test Power :
AC 230V/50Hz
Highest parameter values during test:
V_RMS (Volts): 229.52
V_RMS (Volts): 229.52
Frequency(Hz): 50.00
I_Peak (Amps): 1.147
I_RMS (Amps):
0.250
I_Fund (Amps): 0.094
Crest Factor:
5.383
Power (Watts):
19.7
Power Factor:
0.353
Test Mode:
AUX IN / Subwoofer, TianBao
Harm# Harmonics V-rms
Limit V-rms
% of Limit
Status
2
0.126
0.459
27.45
OK
3
0.534
2.065
25.84
OK
4
0.066
0.459
14.33
OK
5
0.078
0.918
8.50
OK
6
0.033
0.459
7.27
OK
7
0.035
0.689
5.08
OK
8
0.018
0.459
3.89
OK
9
0.024
0.459
5.28
OK
10
0.021
0.459
4.57
OK
11
0.063
0.230
27.48
OK
12
0.020
0.229
8.74
OK
13
0.048
0.230
21.01
OK
14
0.010
0.229
4.54
OK
15
0.037
0.230
16.13
OK
16
0.012
0.229
5.39
OK
17
0.046
0.229
19.90
OK
18
0.015
0.230
6.63
OK
19
0.044
0.230
19.09
OK
20
0.016
0.230
6.77
OK
21
0.037
0.230
16.22
OK
22
0.014
0.230
6.13
OK
23
0.031
0.230
13.61
OK
24
0.008
0.229
3.50
OK
25
0.033
0.229
14.57
OK
26
0.007
0.230
3.09
OK
27
0.021
0.230
9.16
OK
28
0.009
0.229
3.79
OK
29
0.017
0.229
7.55
OK
30
0.006
0.230
2.67
OK
31
0.013
0.229
5.71
OK
32
0.006
0.230
2.73
OK
33
0.017
0.230
7.21
OK
34
0.003
0.229
1.50
OK
35
0.010
0.230
4.31
OK
36
0.004
0.229
1.62
OK
37
0.011
0.230
4.84
OK
38
0.005
0.230
2.22
OK
39
0.010
0.229
4.16
OK
40
0.006
0.230
2.76
OK
Click on the first or last page to see other SB 300 (serv.man6) service manuals if exist.