Report No.: NEI-EMC-1-1009C113 Page 53 of 97
Harmonics – Class-A per Ed. 3.2(Run time)
EUT:
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature:
23℃
Relative Humidity: 47%
Pressure: 1010
hPa
Test Power :
AC 230V/50Hz
Test Mode :
AUX IN / Subwoofer, HanWei
Current & voltage waveforms
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
-300
-200
-100
0
100
200
300
Current (Amps)
Voltage (Volts)
Limits
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
Test result: Pass Worst harmonic was #15 with 34.39% of the limit.
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 54 of 97
Current Test Result Summary (Run time)
EUT:
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature:
23℃
Relative Humidity: 47%
Pressure: 1010
hPa
Test Power :
AC 230V/50Hz
Highest parameter values during test:
V_RMS (Volts): 229.51
V_RMS (Volts): 229.51
Frequency(Hz): 50.00
I_Peak (Amps): 1.046
I_RMS (Amps):
0.230
I_Fund (Amps): 0.113
Crest Factor:
5.381
Power (Watts):
19.6
Power Factor:
0.374
Test Mode :
AUX IN / Subwoofer, HanWei
Harm#Harms(avg)100%Limit%of Limit Harms(max) 150%Limit %of Limit Status
2 0.001 1.080 0.0
0.002 1.620 0.13
Pass
3 0.083 2.300 3.6
0.085 3.450 2.46
Pass
4 0.001 0.430 0.0
0.002 0.645 0.30
Pass
5 0.080 1.140 7.0
0.081 1.710 4.72
Pass
6 0.001 0.300 0.0
0.002 0.450 0.39
Pass
7 0.076 0.770 9.9
0.077 1.155 6.67
Pass
8 0.001 0.230 0.0
0.002 0.345 0.47
Pass
9 0.071 0.400 17.7
0.072 0.600 11.96
Pass
10 0.001 0.184 0.0
0.001 0.276 0.54
Pass
11 0.065 0.330 19.8
0.066 0.495 13.29
Pass
12 0.002 0.153 0.0
0.002 0.230 1.07
Pass
13 0.059 0.210 27.9
0.059 0.315 18.74
Pass
14 0.001 0.131 0.0
0.001 0.197 0.66
Pass
15 0.052 0.150 34.4
0.052 0.225 23.07
Pass
16 0.001 0.115 0.0
0.001 0.173 0.69
Pass
17 0.044 0.132 33.6
0.045 0.199 22.45
Pass
18 0.001 0.102 0.0
0.001 0.153 0.78
Pass
19 0.037 0.118 31.3
0.037 0.178 21.04
Pass
20 0.001 0.092 0.0
0.001 0.138 0.78
Pass
21 0.030 0.107 27.9
0.030 0.161 18.82
Pass
22 0.001 0.084 0.0
0.001 0.125 0.81
Pass
23 0.023 0.098 23.6
0.024 0.147 16.03
Pass
24 0.001 0.077 0.0
0.001 0.115 0.72
Pass
25 0.017 0.090 18.7
0.017 0.135 12.82
Pass
26 0.001 0.071 0.0
0.001 0.106 0.76
Pass
27 0.011 0.083 13.5
0.012 0.125 9.38
Pass
28 0.001 0.066 0.0
0.001 0.099 1.01
Pass
29 0.006 0.078 8.3
0.007 0.116 5.94
Pass
30 0.000 0.061 0.0
0.001 0.092 0.64
Pass
31 0.003 0.073 0.0
0.003 0.109 2.90
Pass
32 0.000 0.058 0.0
0.001 0.086 0.60
Pass
33 0.001 0.068 0.0
0.002 0.102 1.92
Pass
34 0.000 0.054 0.0
0.000 0.081 0.61
Pass
35 0.004 0.064 0.0
0.004 0.096 4.11
Pass
36 0.000 0.051 0.0
0.000 0.077 0.62
Pass
37 0.005 0.061 8.4
0.005 0.091 5.90
Pass
38 0.000 0.048 0.0
0.001 0.073 0.70
Pass
39 0.006 0.058 10.2
0.006 0.087 6.99
Pass
40 0.000 0.046 0.0
0.000 0.069 0.71
Pass
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 55 of 97
Voltage Source Verification Data (Run time)
EUT:
Powered soundbar with
powered woofer
powered woofer
Model Name :
SB300
Temperature:
23℃
Relative Humidity: 47%
Pressure: 1010
hPa
Test Power :
AC 230V/50Hz
Highest parameter values during test:
V_RMS (Volts): 229.51
V_RMS (Volts): 229.51
Frequency(Hz): 50.00
I_Peak (Amps): 1.046
I_RMS (Amps):
0.230
I_Fund (Amps): 0.113
Crest Factor:
5.381
Power (Watts):
19.6
Power Factor:
0.374
Test Mode:
AUX IN / Subwoofer, HanWei
Harm# Harmonics V-rms
Limit V-rms
% of Limit
Status
2
0.121
0.459
26.44
OK
3
0.530
2.066
25.67
OK
4
0.065
0.459
14.19
OK
5
0.070
0.918
7.61
OK
6
0.034
0.459
7.41
OK
7
0.039
0.689
5.60
OK
8
0.018
0.459
3.89
OK
9
0.015
0.459
3.25
OK
10
0.021
0.459
4.48
OK
11
0.058
0.229
25.42
OK
12
0.020
0.230
8.63
OK
13
0.042
0.229
18.50
OK
14
0.010
0.230
4.46
OK
15
0.041
0.229
17.73
OK
16
0.012
0.229
5.10
OK
17
0.040
0.229
17.25
OK
18
0.016
0.229
6.82
OK
19
0.038
0.230
16.38
OK
20
0.016
0.229
6.92
OK
21
0.034
0.229
14.89
OK
22
0.014
0.229
6.25
OK
23
0.029
0.229
12.84
OK
24
0.008
0.229
3.48
OK
25
0.022
0.230
9.73
OK
26
0.007
0.230
3.25
OK
27
0.017
0.229
7.31
OK
28
0.008
0.229
3.42
OK
29
0.010
0.229
4.23
OK
30
0.006
0.229
2.71
OK
31
0.007
0.229
2.98
OK
32
0.006
0.229
2.40
OK
33
0.005
0.230
2.29
OK
34
0.003
0.229
1.43
OK
35
0.006
0.230
2.76
OK
36
0.003
0.229
1.51
OK
37
0.012
0.229
5.19
OK
38
0.005
0.229
2.31
OK
39
0.014
0.230
6.00
OK
40
0.006
0.230
2.65
OK
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 56 of 97
4.5 VOLTAGE FLUCTUATION AND FLICKS MEASUREMENT
4.5.1 LIMITS OF VOLTAGE FLUCTUATION AND FLICKSMEASUREMENT
Limits
Tests
IEC555-3 IEC
61000-3-3
Descriptions
Pst
≤ 1.0, Tp= 10 min.
≤ 1.0, Tp= 10 min.
Short Term Flicker Indicator
Plt N/A
≤ 0.65, Tp=2 hr.
Long Term Flicker Indicator
dc
≤ 3 %
≤ 3 %
Relative Steady-State V-Chang
dmax
≤ 4 %
≤ 4 %
Maximum Relative V-change
d (t)
N/A
≤ 3% for > 200 ms
Relative V-change characteristic
4.5.2 MEASUREMENT INSTRUMENTS LIST
Item Kind of Equipment
Manufacturer
Type No.
Serial No.
Calibrated until
1 Harmonic
&
Flicker
California
PACS-1
72344
May.27.2011
2 Power
Source
California
3001iX
56309
May.27.2011
Remark: ” N/A” denotes No Model Name / Serial No. and No Calibration specified.
4.5.3 TEST PROCEDURE
a. Harmonic Current Test:
Test was performed according to the procedures specified in Clause 5.0 of IEC555-2 and/or
Sub-clause 6.2 of IEC 61000-3-2 depend on which standard adopted for compliance
measurement.
Sub-clause 6.2 of IEC 61000-3-2 depend on which standard adopted for compliance
measurement.
b. Fluctuation and Flickers Test:
Tests was performed according to the Test Conditions/Assessment of Voltage Fluctuations
specified in Clause 5.0/6.0 of IEC555-3 and/or Clause 6.0/4.0 of IEC 61000-3-3 depend on
which standard adopted for compliance measurement.
specified in Clause 5.0/6.0 of IEC555-3 and/or Clause 6.0/4.0 of IEC 61000-3-3 depend on
which standard adopted for compliance measurement.
c. All types of harmonic current and/or voltage fluctuation in this report are assessed by direct
measurement using flicker-meter.
d. For the actual test configuration, please refer to the related Item –Block Diagram of system
tested (please refer to 3.3).
4.5.4 DEVIATION FROM TEST STANDARD
No deviation
No deviation
Click on the first or last page to see other SB 300 (serv.man6) service manuals if exist.