DOWNLOAD JBL SB 300 (serv.man6) Service Manual ↓ Size: 1.51 MB | Pages: 97 in PDF or view online for FREE

Model
SB 300 (serv.man6)
Pages
97
Size
1.51 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sb-300-sm6.pdf
Date

JBL SB 300 (serv.man6) EMC - CB Certificate ▷ View online

Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 53 of 97
 
 
Harmonics – Class-A per Ed. 3.2(Run time)
 
EUT: 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature: 
23℃ 
Relative Humidity: 47% 
Pressure: 1010 
hPa 
Test Power : 
AC 230V/50Hz 
Test Mode : 
AUX IN / Subwoofer, HanWei 
 
Current & voltage waveforms 
   
 
-1.5
-1.0
-0.5
0.0
0.5
1.0
1.5
-300
-200
-100
0
100
200
300
  
Current (Amps)
Voltage (Volts)
 
Limits 
 
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
  
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
 
 
Test result:    Pass          Worst harmonic was #15 with 34.39% of the limit.   
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 54 of 97
 
 
Current Test Result Summary (Run time) 
EUT: 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature: 
23℃ 
Relative Humidity: 47% 
Pressure: 1010 
hPa 
Test Power : 
AC 230V/50Hz 
Highest parameter values during test: 
V_RMS (Volts):  229.51 
Frequency(Hz): 50.00 
I_Peak (Amps):  1.046 
I_RMS (Amps): 
0.230 
I_Fund (Amps):  0.113 
Crest Factor: 
5.381 
Power (Watts): 
19.6 
Power Factor: 
0.374 
Test Mode : 
AUX IN / Subwoofer, HanWei 
 
Harm#Harms(avg)100%Limit%of Limit Harms(max) 150%Limit %of Limit  Status 
 
 
2  0.001 1.080  0.0 
0.002 1.620  0.13 
Pass 
 
3  0.083 2.300  3.6 
0.085 3.450  2.46 
Pass 
 
4  0.001 0.430  0.0 
0.002 0.645  0.30 
Pass 
 
5  0.080 1.140  7.0 
0.081 1.710  4.72 
Pass 
 
6  0.001 0.300  0.0 
0.002 0.450  0.39 
Pass 
 
7  0.076 0.770  9.9 
0.077 1.155  6.67 
Pass 
 
8  0.001 0.230  0.0 
0.002 0.345  0.47 
Pass 
 
9  0.071 0.400  17.7 
0.072 0.600 11.96 
Pass 
 
10  0.001 0.184  0.0 
0.001 0.276  0.54 
Pass 
 
11  0.065 0.330  19.8 
0.066 0.495 13.29 
Pass 
 
12  0.002 0.153  0.0 
0.002 0.230  1.07 
Pass 
 
13  0.059 0.210  27.9 
0.059 0.315 18.74 
Pass 
 
14  0.001 0.131  0.0 
0.001 0.197  0.66 
Pass 
 
15  0.052 0.150  34.4 
0.052 0.225 23.07 
Pass 
 
16  0.001 0.115  0.0 
0.001 0.173  0.69 
Pass 
 
17  0.044 0.132  33.6 
0.045 0.199 22.45 
Pass 
 
18  0.001 0.102  0.0 
0.001 0.153  0.78 
Pass 
 
19  0.037 0.118  31.3 
0.037 0.178 21.04 
Pass 
 
20  0.001 0.092  0.0 
0.001 0.138  0.78 
Pass 
 
21  0.030 0.107  27.9 
0.030 0.161 18.82 
Pass 
 
22  0.001 0.084  0.0 
0.001 0.125  0.81 
Pass 
 
23  0.023 0.098  23.6 
0.024 0.147 16.03 
Pass 
 
24  0.001 0.077  0.0 
0.001 0.115  0.72 
Pass 
 
25  0.017 0.090  18.7 
0.017 0.135 12.82 
Pass 
 
26  0.001 0.071  0.0 
0.001 0.106  0.76 
Pass 
 
27  0.011 0.083  13.5 
0.012 0.125  9.38 
Pass 
 
28  0.001 0.066  0.0 
0.001 0.099  1.01 
Pass 
 
29  0.006 0.078  8.3 
0.007 0.116  5.94 
Pass 
 
30  0.000 0.061  0.0 
0.001 0.092  0.64 
Pass 
 
31  0.003 0.073  0.0 
0.003 0.109  2.90 
Pass 
 
32  0.000 0.058  0.0 
0.001 0.086  0.60 
Pass 
 
33  0.001 0.068  0.0 
0.002 0.102  1.92 
Pass 
 
34  0.000 0.054  0.0 
0.000 0.081  0.61 
Pass 
 
35  0.004 0.064  0.0 
0.004 0.096  4.11 
Pass 
 
36  0.000 0.051  0.0 
0.000 0.077  0.62 
Pass 
 
37  0.005 0.061  8.4 
0.005 0.091  5.90 
Pass 
 
38  0.000 0.048  0.0 
0.001 0.073  0.70 
Pass 
 
39  0.006 0.058  10.2 
0.006 0.087  6.99 
Pass 
 
40  0.000 0.046  0.0 
0.000 0.069  0.71 
Pass 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 55 of 97
 
 
Voltage Source Verification Data (Run time) 
EUT: 
Powered soundbar with 
powered woofer   
Model Name : 
SB300 
Temperature: 
23℃ 
Relative Humidity: 47% 
Pressure: 1010 
hPa 
Test Power : 
AC 230V/50Hz 
Highest parameter values during test: 
V_RMS (Volts):  229.51 
Frequency(Hz): 50.00 
I_Peak (Amps):  1.046 
I_RMS (Amps): 
0.230 
I_Fund (Amps):  0.113 
Crest Factor: 
5.381 
Power (Watts): 
19.6 
Power Factor: 
0.374 
Test Mode: 
AUX IN / Subwoofer, HanWei 
 
Harm#  Harmonics V-rms 
Limit V-rms 
% of Limit 
Status 
 
 2 
0.121 
0.459 
26.44 
OK 
 3 
0.530 
2.066 
25.67 
OK 
 4 
0.065 
0.459 
14.19 
OK 
 5 
0.070 
0.918 
7.61 
OK 
 6 
0.034 
0.459 
7.41 
OK 
 7 
0.039 
0.689 
5.60 
OK 
 8 
0.018 
0.459 
3.89 
OK 
 9 
0.015 
0.459 
3.25 
OK 
 10 
0.021 
0.459 
4.48 
OK 
 11 
0.058 
0.229 
25.42 
OK 
 12 
0.020 
0.230 
8.63 
OK 
 13 
0.042 
0.229 
18.50 
OK 
 14 
0.010 
0.230 
4.46 
OK 
 15 
0.041 
0.229 
17.73 
OK 
 16 
0.012 
0.229 
5.10 
OK 
 17 
0.040 
0.229 
17.25 
OK 
 18 
0.016 
0.229 
6.82 
OK 
 19 
0.038 
0.230 
16.38 
OK 
 20 
0.016 
0.229 
6.92 
OK 
 21 
0.034 
0.229 
14.89 
OK 
 22 
0.014 
0.229 
6.25 
OK 
 23 
0.029 
0.229 
12.84 
OK 
 24 
0.008 
0.229 
3.48 
OK 
 25 
0.022 
0.230 
9.73 
OK 
 26 
0.007 
0.230 
3.25 
OK 
 27 
0.017 
0.229 
7.31 
OK 
 28 
0.008 
0.229 
3.42 
OK 
 29 
0.010 
0.229 
4.23 
OK 
 30 
0.006 
0.229 
2.71 
OK 
 31 
0.007 
0.229 
2.98 
OK 
 32 
0.006 
0.229 
2.40 
OK 
 33 
0.005 
0.230 
2.29 
OK 
 34 
0.003 
0.229 
1.43 
OK 
 35 
0.006 
0.230 
2.76 
OK 
 36 
0.003 
0.229 
1.51 
OK 
 37 
0.012 
0.229 
5.19 
OK 
 38 
0.005 
0.229 
2.31 
OK 
 39 
0.014 
0.230 
6.00 
OK 
 40 
0.006 
0.230 
2.65 
OK 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 56 of 97
 
 
 
4.5 VOLTAGE FLUCTUATION AND FLICKS MEASUREMENT 
 
4.5.1 LIMITS OF VOLTAGE FLUCTUATION AND FLICKSMEASUREMENT 
 
 
 
 
Limits 
Tests 
IEC555-3 IEC 
61000-3-3 
 
 Descriptions 
Pst 
≤ 1.0, Tp= 10 min. 
 
≤ 1.0, Tp= 10 min. 
Short Term Flicker Indicator 
Plt N/A 
 
≤ 0.65, Tp=2 hr. 
Long Term Flicker Indicator 
dc 
≤ 3 % 
 
≤ 3 % 
Relative Steady-State V-Chang 
dmax 
≤ 4 % 
 
≤ 4 % 
Maximum Relative V-change 
d (t) 
N/A 
 
≤ 3% for > 200 ms 
Relative V-change characteristic
 
 
4.5.2 MEASUREMENT INSTRUMENTS LIST 
   
Item  Kind of Equipment 
Manufacturer 
Type No. 
Serial No. 
Calibrated until 
1 Harmonic 
Flicker 
California 
PACS-1 
72344 
May.27.2011 
2 Power 
Source 
California 
3001iX 
56309 
May.27.2011 
 
  Remark: ” N/A” denotes No Model Name / Serial No. and No Calibration specified. 
 
  
 
4.5.3 TEST PROCEDURE 
a. Harmonic Current Test:   
Test was performed according to the procedures specified in Clause 5.0 of IEC555-2 and/or 
Sub-clause 6.2 of IEC 61000-3-2 depend on which standard adopted for compliance 
measurement. 
b. Fluctuation and Flickers Test:   
Tests was performed according to the Test Conditions/Assessment of Voltage Fluctuations 
specified in Clause 5.0/6.0 of IEC555-3 and/or Clause 6.0/4.0 of IEC 61000-3-3 depend on 
which standard adopted for compliance measurement. 
c. All types of harmonic current and/or voltage fluctuation in this report are assessed by direct 
measurement using flicker-meter. 
d. For the actual test configuration, please refer to the related Item –Block Diagram of system 
tested (please refer to 3.3). 
  
4.5.4 DEVIATION FROM TEST STANDARD 
No deviation   
Page of 97