JBL SB 300 (serv.man6) EMC - CB Certificate ▷ View online
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 5 of 97
Table of Contents
Page
5.6.3 TEST PROCEDURE
69
5.6.4 TEST RESULT
70
5.7 ESD TESTING
74
5.7.1 TEST SPECIFICATION
74
5.7.2 MEASUREMENT INSTRUMENTS
74
5.7.3 TEST PROCEDURE
74
5.7.4 DEVIATION FROM TEST STANDARD
75
5.7.5 TEST SETUP
75
5.7.6 TEST RESULTS
76
5.7.7 PHOTO(S) SHOWN THE LOCATION(S) OF ESD EVALUATED
77
5.8 EFT/BURST TESTING
78
5.8.1 TEST SPECIFICATION
78
5.8.2 MEASUREMENT INSTRUMENTS
78
5.8.3 TEST PROCEDURE
78
5.8.4 DEVIATION FROM TEST STANDARD
78
5.8.5 TEST SETUP
79
5.8.6 TEST RESULTS
80
6. ATTACHMENT MEASUREMENT DATA
81
7. EUT TEST PHOTO
95
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 6 of 97
1. CERTIFICATION
E q u i p m e n t : Powered soundbar with powered woofer
Brand
Name
:
JBL
Model
Name
:
SB300
A p p l i c a n t : Harman Consumer, Inc.
F a c t o r y
F a c t o r y
: GUOGUANG ELECTRIC CO., Ltd
A d d r e s s
: No.8 Jinghu Road, Xinhua Town, Huadu Reg. Guangzhou, 510800
Date of Test : Oct. 21, 2010 ~ Jan. 05, 2011
T e s t
T e s t
I t e m
:
ENGINEERING
SAMPLE
S t a n d a r d s
: EN
55013: 2001+A1: 2003+A2: 2006
EN 61000-3-2:2006 Class A
EN
61000-3-3:2008
EN 55020: 2007
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006+A1:2007+A2:2010
IEC 61000-4-4: 2004+A1:2010
The above equipment has been tested and found compliance with the requirement of the relative
standards by Neutron Engineering Inc. EMC Laboratory.
The test data, data evaluation, and equipment configuration contained in our test report (Ref No.
NEI-EMC-1-1009C113) were obtained utilizing the test procedures, test instruments, test sites that
has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality
assessment standard and technical standard(s).
standards by Neutron Engineering Inc. EMC Laboratory.
The test data, data evaluation, and equipment configuration contained in our test report (Ref No.
NEI-EMC-1-1009C113) were obtained utilizing the test procedures, test instruments, test sites that
has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality
assessment standard and technical standard(s).
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 7 of 97
2. SUMMARY OF TEST RESULTS
Test procedures according to the technical standards:
EMC Emission
Standard
Test Item
Limit
Judgment Remark
Mains Terminal Disturbance
Voltage Test
------ PASS
Disturbance Power Test
------
PASS
Radiated Disturbance Test
------
N/A
EN 55013: 2001+A1:
2003+A2: 2006
Disturbance Voltage at the
Antenna Terminals Test
------ N/A
EN 61000-3-2:2006
Harmonic Current Emission
Class A
PASS
EN 61000-3-3:2008
Voltage Fluctuations & Flicker
------
PASS
EMC Immunity
(EN 55020: 2007)
Section
Test Item
Performance
Criteria
Judgment Remark
Input immunity
(S1)
------ N/A
Immunity against
RFI voltages (S2a)
------ PASS
Immunity against
RFI currents (S2b)
------ N/A
Immunity against radiated RFI
(S3)
------ PASS
Screening effectiveness
(S4)
------ N/A
Immunity to electromagnetic
fields Keyed Carrier
(S5)
------ PASS
EN 55020
(2007)
Immunity against radiated RFI
(S6)
------ N/A
IEC 61000-4-2
(2008)
Electrostatic Discharge
B
PASS
IEC 61000-4-3
(2006+A1:2007+A2:2010)
RS electromagnetic field
A
PASS
IEC 61000-4-4
(2004+A1:2010)
Fast transients
B
PASS
NOTE:
(1)” N/A” denotes test is not applicable in this Test Report
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 8 of 97
2.1 TEST FACILITY
The test facilities used to collect the test data in this report is SR01/SR03 at the location of
No.3,Jinshagang 1st Road, ShiXia, Dalang Town,Dong Guan, China.523792.
2.2 MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated
for tests performed on the EUT as specified in CISPR 16-4-2:
for tests performed on the EUT as specified in CISPR 16-4-2:
The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
approximately 95 %。
A. Mains Terminal Disturbance Voltage Test : 2.44 dB
B. Radiated Disturbance Test :
Test Site Method
Measurement Frequency
Range
Ant.
H / V
U,(dB)
NOTE
SR01
30MHz ~ 300MHz
2.64
SR03
2.85
C. Harmonic/ Flicker Measurement :
Test item
U
NOTE
IEC 61000-3-2 Voltage: 0.04%; Current: .191%; Frequency: 2.8x10
-10
IEC 61000-3-3 Voltage: 0.04%; Current: .191%; Frequency: 2.8x10
-10
D. Immunity Measurement :
Test item
U
NOTE
IEC 61000-4-2
Voltage: 1.6%; Timing: 2.8%
IEC 61000-4-3
2.66 dB
IEC 61000-4-4
Voltage: 1.6%; Timing: 2.8%; Frequency: 2.8x10
-10