DOWNLOAD JBL SB 300 (serv.man6) Service Manual ↓ Size: 1.51 MB | Pages: 97 in PDF or view online for FREE

Model
SB 300 (serv.man6)
Pages
97
Size
1.51 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
sb-300-sm6.pdf
Date

JBL SB 300 (serv.man6) EMC - CB Certificate ▷ View online

Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 5 of 97
 
 
 
Table of Contents 
 
 
 
Page 
5.6.3 TEST PROCEDURE 
69
 
5.6.4 TEST RESULT 
70
 
5.7 ESD TESTING 
74
 
5.7.1 TEST SPECIFICATION 
74
 
5.7.2 MEASUREMENT INSTRUMENTS 
74
 
5.7.3 TEST PROCEDURE 
74
 
5.7.4 DEVIATION FROM TEST STANDARD 
75
 
5.7.5 TEST SETUP 
75
 
5.7.6 TEST RESULTS 
76
 
5.7.7 PHOTO(S) SHOWN THE LOCATION(S) OF ESD EVALUATED 
77
 
5.8 EFT/BURST TESTING 
78
 
5.8.1 TEST SPECIFICATION 
78
 
5.8.2 MEASUREMENT INSTRUMENTS 
78
 
5.8.3 TEST PROCEDURE 
78
 
5.8.4 DEVIATION FROM TEST STANDARD 
78
 
5.8.5 TEST SETUP 
79
 
5.8.6 TEST RESULTS 
80
 
6. ATTACHMENT MEASUREMENT DATA
 81
 
7. EUT TEST PHOTO
 95
 
 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 6 of 97
 
 
 
1. CERTIFICATION 
 
  E q u i p m e n t :  Powered soundbar with powered woofer   
 Brand 
Name 
JBL 
 Model 
Name 
SB300   
  A p p l i c a n t :  Harman Consumer, Inc. 
  F a c t o r y 
: GUOGUANG ELECTRIC CO., Ltd 
  A d d r e s s 
: No.8 Jinghu Road, Xinhua Town, Huadu Reg. Guangzhou, 510800 
  Date  of  Test :  Oct. 21, 2010 ~ Jan. 05, 2011 
 T e s t  
I t e m 
ENGINEERING 
SAMPLE 
  S t a n d a r d s 
: EN 
55013: 2001+A1: 2003+A2: 2006 
 
 
  EN 61000-3-2:2006 Class A 
  
 
EN 
61000-3-3:2008 
 
 
  EN 55020: 2007 
 
 
  IEC 61000-4-2: 2008 
 
 
  IEC 61000-4-3: 2006+A1:2007+A2:2010 
 
 
  IEC 61000-4-4: 2004+A1:2010 
 
 
 
The above equipment has been tested and found compliance with the requirement of the relative 
standards by Neutron Engineering Inc. EMC Laboratory. 
The test data, data evaluation, and equipment configuration contained in our test report (Ref No. 
NEI-EMC-1-1009C113) were obtained utilizing the test procedures, test instruments, test sites that 
has been accredited by the Authority of NVLAP and TAF according to the ISO-17025 quality 
assessment standard and technical standard(s).   
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 7 of 97
 
 
2. SUMMARY OF TEST RESULTS 
 
Test procedures according to the technical standards: 
EMC Emission                           
Standard 
Test Item 
Limit 
Judgment  Remark
Mains Terminal Disturbance 
Voltage Test 
------ PASS  
Disturbance Power Test 
------ 
PASS 
 
Radiated Disturbance Test 
------ 
N/A 
 
EN 55013: 2001+A1: 
2003+A2: 2006
 
Disturbance Voltage at the 
Antenna Terminals Test 
------ N/A  
EN 61000-3-2:2006   
Harmonic Current Emission 
Class A
 
PASS  
EN 61000-3-3:2008 
Voltage Fluctuations & Flicker
------ 
PASS 
 
EMC Immunity 
(EN 55020: 2007)
 
Section 
Test Item 
Performance 
Criteria 
Judgment Remark
Input immunity 
 (S1) 
------ N/A 
 
Immunity against 
RFI voltages (S2a) 
------ PASS 
 
Immunity against 
RFI currents (S2b) 
------ N/A 
 
Immunity against radiated RFI 
(S3) 
------ PASS 
 
Screening effectiveness   
(S4) 
------ N/A 
 
Immunity to electromagnetic 
fields Keyed Carrier   
(S5) 
------ PASS 
 
EN 55020 
(2007) 
Immunity against radiated RFI 
(S6) 
------ N/A 
 
IEC 61000-4-2 
(2008) 
Electrostatic Discharge 
PASS 
 
IEC 61000-4-3 
(2006+A1:2007+A2:2010) 
RS electromagnetic field 
PASS 
 
IEC 61000-4-4 
(2004+A1:2010) 
Fast transients 
PASS 
 
NOTE: 
 
(1)” N/A” denotes test is not applicable in this Test Report 
 
 
 
 
 
 
 
 
 
 
Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 8 of 97
 
 
2.1 TEST FACILITY 
  The test facilities used to collect the test data in this report is SR01/SR03  at the location of 
No.3,Jinshagang 1st Road, ShiXia, Dalang Town,Dong Guan, China.523792. 
 
2.2 MEASUREMENT UNCERTAINTY   
 
Where relevant, the following measurement uncertainty levels have been estimated 
for tests performed on the EUT as specified in CISPR 16-4-2: 
 
The reported uncertainty of measurement y  ±  U,where expended uncertainty is based on a 
standard uncertainty multiplied by a coverage factor of    k=2,providing a level of confidence of 
approximately 95 %。 
 
A. Mains Terminal Disturbance Voltage Test : 2.44 dB 
 
B. Radiated Disturbance Test : 
 
Test Site  Method
Measurement Frequency 
Range 
Ant. 
H / V
U,(dB) 
NOTE 
SR01 
 
30MHz ~ 300MHz 
 
2.64 
 
SR03  
 
 2.85 
 
 
  C. Harmonic/ Flicker Measurement : 
 
Test item 
NOTE 
IEC 61000-3-2  Voltage: 0.04%; Current: .191%; Frequency: 2.8x10
-10
 
 
IEC 61000-3-3  Voltage: 0.04%; Current: .191%; Frequency: 2.8x10
-10
 
 
       
  D. Immunity Measurement : 
 
Test item 
NOTE 
IEC 61000-4-2 
Voltage: 1.6%; Timing: 2.8% 
 
IEC 61000-4-3 
2.66 dB 
 
IEC 61000-4-4 
Voltage: 1.6%; Timing: 2.8%; Frequency: 2.8x10
-10  
 
 
       
 
Page of 97