DOWNLOAD Sharp MX-PEX1 (serv.man13) Service Manual ↓ Size: 1.33 MB | Pages: 86 in PDF or view online for FREE

Model
MX-PEX1 (serv.man13)
Pages
86
Size
1.33 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
Copying Equipment / Fiery PEX1 Configuration Setup Guide
File
mx-pex1-sm13.pdf
Date

Sharp MX-PEX1 (serv.man13) User Manual / Operation Manual ▷ View online

S
ETUP
 
OPTION
 
REFERENCE
61
Font Number
0-999
Designates the default font for the Fiery X3eTY2. To determine font 
numbers, print the internal PCL Font List. The standard fonts are listed 
in order. The font numbers, however, are not displayed.
Font Pitch (char/in)
0.44-99.99 (default is 10.00)
If the default PCL font selected in Font Number represents a fixed pitch 
scalable font, determine the width of scalable type. Pitch is measured by 
characters per inch, so 10-pitch type fits 10 characters per inch. 
Font Size (pt) 
4.0-999.75 (default is 12.00)
If the default PCL font selected in Font Number represents a 
proportionally spaced scalable font, determine the point size (height) of 
the font. 
Font Source
Internal, Soft Font
Specify the PCL font source to be enabled. 
Form Length (lines)
5-128 (default is 60)
Sets the number of lines to be printed per page in PCL jobs.
Halftone Screen
Screen 1, Screen 2, Screen 3
Specify a halftone screening method. See 
Color Printing
.
Image Smoothing
Automatic, Off, On, Below 
90 ppi, Below 150 ppi, Below 200 
ppi, Below 300 ppi
Select On to minimize grainy output when printing low-resolution 
images. If you select On, Image Smoothing is applied to all images.
Select Automatic to use smoothing only when it makes a visible 
difference. When the image is below 150 ppi, image smoothing is 
applied automatically.
Select one of the “ppi” choices (pixels per inch) to apply image 
smoothing to those images whose effective resolution is below the 
specified ppi value.
Output Profile
Default profile
Specify the default output profile to use for printing. Additional profiles 
can be created and downloaded to the Fiery X3eTY2 with ColorWise 
Pro Tools.
Page Order 
Forward, Reverse
Select Forward to print the pages of your job from first to last. 
Select Reverse to print the pages of your job from last to first.
Paper Size
Letter, A4, 11
x
17, A3 (default is 
Letter in the United States, A4 
elsewhere)
Specify the default paper size that the Fiery X3eTY2 uses to print 
PCL jobs.
Paper Size for System 
Pages
US, Metric (default is US in the 
United States, Metric elsewhere)
Specify the paper size that PCL system pages print on. System pages are 
pages that you print from the MFP touch panel, such as the PCL Font 
List.
Print Cover Page
Yes, No
Prints a cover page (job summary) at the end of each print job. If you 
select Yes, each print job is followed by a page containing the name of the 
user who sent the job, the document name, the server name, the time the 
job was printed, the number of pages printed, and the status of the job. If 
a PostScript error occurs and the Print to PS Error option is set to Yes, 
the cover page lists the PostScript error message instead of the job status.
Print Gray Using Black 
Only (CMYK) 
Off, Text/Graphics, Text/Graphics/
Images
Prints gray in an CMYK job as pure black. Specify the items of the job 
that you want to print as black only. 
Option  
Settings
(default is underlined)
Description
S
ETUP
 
OPTION
 
REFERENCE
62
Print Gray Using Black 
Only (RGB) 
Off, Text/Graphics, Text/Graphics/
Images
Prints gray in an RGB job as pure black. Specify the items of the job that 
you want to print as black only. 
Print Master
Yes, No
Select Yes to print a FreeForm master when created and printed to the 
Fiery X3eTY2. The master is retained on the Fiery X3eTY2 after 
printing unless deleted later. Select No only to process and hold a 
FreeForm master on the Fiery X3eTY2.
Print to PS Error
Yes, No
Specify whether the Fiery X3eTY2 should print the available portion of a 
print job when it encounters a PostScript error. Select Yes to print the 
portion of the job that was processed before the error occurred; select No 
to cancel the print job entirely when a PostScript error is encountered. 
Select No unless you encounter printing problems.
Rendering Style
Photographic, Presentation, Abs. 
Colorimetric, Rel. Colorimetric
The color rendering dictionary (CRD) defines how colors are converted 
from the RGB color space to device CMYK. Photographic, designed for 
images, retains the relative balance between colors to maintain the overall 
appearance of the image. Presentation, designed for bright colors, 
produces the saturated prints needed for most business presentations, but 
handles photographic images the same way as the Photographic CRD. 
Absolute Colorimetric provides the closest match to the CMYK device 
being simulated, including rendering the paper color as the background. 
Relative Colorimetric provides a close match to the CMYK device being 
simulated, regardless of the media used.
RGB Separation
Output, Simulation
Defines how the Fiery X3eTY2 processes RGB jobs. Select Output for 
RGB jobs that you print to the final output device. Select Simulation to 
simulate an output device that is not the device to which you are 
printing.
RGB Source Profile
EFIRGB, sRGB (PC), Apple 
Standard, Adobe RGB(1998), 
ECI-RGB.icc, Fiery RGB v2, 
None
The RGB source is the color space used to control color for conversion 
from monitor to printed output. EFIRGB is based on the reference 
points used in the creation of the Fiery X3eTY2 software. sRGB is based 
on an average of a large number of PC monitors. Apple Standard is the 
standard reference point for Apple’s ColorSync software.
Scale to Fit
On, Off
Specify whether to scale a document size to a selected paper size if the 
document size is different from the paper size. With the Off setting, if 
the document size is larger than the selected paper size, the document is 
cropped to the paper size when printed. 
Spot Color Matching
On, Off
Select On and the Fiery X3eTY2 uses an internal lookup table to print 
the best equivalents of PANTONE colors. Select Off and PANTONE 
colors are printed using the CMYK values defined in the original 
applications. For more information, see 
Color Printing
.
Symbol Set
ASCII, Roman_8, ECMA-94 L1, 
PC_8...
Choose the PCL symbol set that best matches the needs of users printing 
to the Fiery X3eTY2.
Option  
Settings
(default is underlined)
Description
C
ONFIGURING
 W
EB
T
OOLS
63
C
ONFIGURING
 W
EB
T
OOLS
WebTools allow you to manage your Fiery X3eTY2 remotely from the Internet or from your 
company’s intranet. The Fiery X3eTY2 has its own home page, from which you can select the 
WebTool to use.
For information about using WebTools, see 
Utilities
.
Configuring the Fiery X3eTY2 and clients for WebTools
WebTools provide access to many Fiery X3eTY2 functions via the Internet (or intranet), 
providing additional flexibility in remote management. After they are enabled, you can access 
the WebTools from a network computer. 
T
O
 
SET
 
UP 
W
EB
T
OOLS
 
ON
 
THE
 F
IERY 
X3
E
TY2
1 In Network Setup on the Fiery X3eTY2, enable TCP/IP.
2 Set a valid, unique IP address, subnet mask, and gateway address (if required) for the 
Fiery X3eTY2.
3 In Network Setup, enable Web Services.
To use WebTools for printing, follow the remaining steps.
4 In Port Setup, enable port 515 (LPD/Fiery Tools).
5 In Printer Setup, confirm that the Print queue is published.
T
O
 
SET
 
UP 
W
EB
T
OOLS
 
ON
 
A
 
COMPUTER
1 Enable TCP/IP networking.
2 Assign the workstation a valid, unique IP address, subnet mask, and gateway address, 
if required.
3 Install an Internet browser that supports the Java language and frames.
Make sure Java is enabled. For more information about supported browsers and WebTools 
requirements, see 
Welcome
.
C
ONFIGURING
 W
EB
T
OOLS
64
T
O
 
ACCESS 
W
EB
T
OOLS
1 Start your Internet browser and type the IP address or DNS name of the Fiery X3eTY2.
2 Click the Fiery button in the lower-left corner.
The Fiery X3eTY2 home page appears.
N
OTE
SSL communication is supported.
3 Click the tab that corresponds to the WebTool that you want to use.
Page of 86
Display

Click on the first or last page to see other MX-PEX1 (serv.man13) service manuals if exist.