MX-M1205  CONFIGURATION  1 – 3
3.  Paper feed/Paper exit Option combinations list
*1: Installation of a second stacker.
: Necessary option
: Necessary option (Use any one of them)
4.  Weight list
Weight of each model
*1: Excluding consumable parts.
Necessary option
MX-FN21
MX-FN22
MX-FD10
MX-RB18
MX-ST10
MX-RB13
MX-RB16
MX-LC13N
MX-RB17
Install 
model
MX-FN21
MX-FN22
MX-FD10
MX-CF11
MX-ST10
MX-ST10
 *1
MX-PN13
MX-TM10
MX-RB13
MX-LC13N
MX-MF11
MX-RB17
MX-LC13N
 *1
Model name
Weight
Main unit
300kg
*1
MX-FN21
61kg
MX-FN22
108kg
MX-TM10
32kg
MX-FD10
66kg
MX-RB13
14.5kg
MX-RB16
1.9kg
MX-RB17
8.1kg
MX-RB18
18.5kg
MX-CF11
23kg
MX-LC12
28.5kg
MX-LC13N
130.3kg
MX-MF11
21kg
MX-ST10
100kg
MX-CA10
15kg
٤
٤
٤
ٌ
٤
ٌ
ٌ
٤
٤
٤
ٌ
ٌ
٤
٤
ٌ
٤
ٌ
٤
٤
٤
٤
٤
٤
٤
٤
٤
٤
ٌ
2
: ‘17/Apr.
2
2
MX-M1205  CONFIGURATION  1 – 4
5.  Power configuration
North America (105cpm, 120cpm)
NOTE:
• Prepare the interior wiring (power outlet) which can be connected to the AC plug of the machine and the option units.
The interior wiring (power outlet) for the machine differs from that for the option units.
In addition, the required number of interior wirings (power outlets) differs depending on the combination of option units.
Prepare the necessary number as needed. 
Example: (Japan) Finisher 3.3A, Stacker 1.3A, 15A > 4.6A = 3.3A + 1.3A  Connectable to a same kind of circuit (breaker).
• Since the machine operates on 200V, an interior wiring work may be required.
• For additional installation of the breaker or 200V interior wiring, ask a professional expert or company.
4K finisher 
(100-sheets 
binding)
Multi-
folding 
unit
Stacker
Stacker
Inserter
Decurler 
unit
Machine 1
Large-
capacity 
multi-stage 
tray
Large-
capacity 
multi-stage 
tray
AC cord type
Inlet
Inlet
Inlet
Inlet
---
---
Direct
Inlet
Inlet
Power rating
120V/2.9A
AC 
supplied 
from the 
finisher 
(1.1A)
120V/1.3A
120V/1.3A
Power 
suplied 
from the 
machine
Power 
suplied 
from the 
machine
240V/15A
120V/8A
120V/8A
Power capacity
120V/20A
---
120V/20A
120V/20A
---
---
240V/20A
120V/20A
120V/20A
Plug shape
---
---
---
Outlet shape
---
---
---
Paper feed system
After-process system
Large-capacity 
multi-stage tray
Large-capacity 
multi-stage tray
Multi-
folding 
unit
4K 
finisher 
(100-she
ets 
binding)
Machine
Decurler unit
Inserter
Stacker
Stacker
AC supplied
MX-M1205  CONFIGURATION  1 – 5
MEMO: The AC cord of the machine for UK is to be changed in SMF.
Europe/UK (105cpm, 120cpm)
MEMO: The AC cord of the machine for UK is to be changed in SMF.
NOTE:
• Prepare the interior wiring (power outlet) which can be connected to the AC plug of the machine and the option units.
In addition, the required number of interior wirings (power outlets) differs depending on the combination of option units.
Prepare the necessary number as needed. 
Example:Finisher 1.5A, Stacker 1.3A, 10A > 2.8A = 1.5A + 1.3A  Connectable to a same kind of circuit (breaker).
• Since the machine for UK operates on 16A, an interior wiring work may be required.
• For additional installation of the breaker or 16A interior wiring, ask a professional expert or company.
4K finisher 
(100-
sheets 
binding)
Multi-
folding 
unit
Stacker
Stacker
Inserter
Decurler 
unit
Machine1 
Europe 
(105com, 
120cpm)
Machine1 
UK 
(105com, 
120cpm)
Large-
capacity 
multi-stage 
tray
Large-
capacity 
multi-stage 
tray
AC cord type
Inlet
Inlet
Inlet
Inlet
---
---
Direct
Direct
Inlet
Inlet
Power rating
230V/1.5A
AC 
supplied
 from the 
finisher 
(0.6A)
230V/1.3A
230V/1.3A
Power 
suplied 
from the 
machine
Power 
suplied 
from the 
machine
230V/13A
240V/13A
230V/4A
230V/4A
Power capacity
230V/20A
---
230V/20A
230V/20A
---
---
230V/20A
240V/20A
230V/20A
230V/20A
Plug shape
---
---
---
Outlet shape
---
---
---
MX-M1205  MX-M1055/M1205 (MAIN UNIT)  2 – 1
MX-M1205
Service Manual
 
[2] MX-M1055/M1205 (MAIN UNIT)
1.  NOTE FOR SERVICING
This Service Manual uses some symbols to assure safe operation.
Please understand the meanings of photographs before servicing.
A. Precautions for servicing
1) When servicing, disconnect the power plug, the printer cable,
the  network  cable,  and  the  telephone  line  from  the  machine,
except when performing the communication test, etc.
It may cause an injury or an electric shock.
2) There  is  a  high  temperature  area  inside  the  machine.  Use
extreme care when servicing.
It may cause a burn.
3) There is a high voltage section inside the machine which may
cause an electric shock. Be careful when servicing.
4) Do  not  disassemble  the  laser  unit.  Do  not  insert  a  reflective
material such as a screwdriver in the laser beam path.
It may damage the eyes by reflection of laser beams.
5) When  servicing  the  machine  while  it  is  operating,  be  careful
when working around chains, belts, gears and drive sections.
6) Do not leave the machine with the cabinet disassembled.
Do not allow any person other than a serviceman access to the
inside of the machine. It may cause an electric shock, a burn,
or an injury.
7) When servicing, do not breathe toner or developer or get toner
or developer in the eyes. If toner or developer contact the eyes,
wash eyes immediately and contact a doctor if necessary.
8) The interior of the machine has sharp edges.   Be careful when
servicing the machine, to avoid contact with these edges.
9) Do not throw toner or a toner cartridge in a fire. Toner is com-
bustible and may explode and burn you.
10) When replacing the lithium battery on the PWB, only use the
specified battery.
If a battery of different specification is used, it may not be com-
patible and cause breakdown or malfunction of the machine.
11) When  carrying  a  PWB,  be  sure  to  transport  the  PWB  in  an
anti-static bag.Failure to do so may cause malfunction or fail-
ure of the PWB.
B. Warning for servicing
1) Be sure to only connect  the power cord to an outlet that meets
the specified voltage and current requirements. Avoid complex
wiring which may lead to a fire or an electric shock.
It may cause a fire or an electric shock.
2) If  there  is  any  abnormality  such  as  a  smoke  or  an  abnormal
smell, interrupt the job and disconnect the power cord.
It may cause a fire or an electric shock.
3) Be sure to connect the grounding wire. If an electric leakage
occurs  without  grounding,  a  fire  or  an  electric  shock  may
result.
To  protect  the  machine  and  the  power  unit  from  lightening,
proper grounding must be made.
4) When  connecting  the grounding  wire, never connect it  to the
following points.
It may cause an explosion, a fire or an electric shock.
• Gas tube
• Lightning conductor
• A water pipe or a water faucet.
• Grounding wire for telephone line
5)
Do not damage, break, or stress the power cord.
Do not put heavy objects on the power cable. Do not forcibly
bend or pull the power cable.
It may cause a fire or an electric shock.
6)
Keep the power cable away from a heat source.
Do not insert the power plug with dust on it into a power outlet.
It may cause a fire or an electric shock.
7)
Do not put any foreign liquid or metal piece (that may fall into
or spill) inside of the machine.
It may cause a fire or an electric shock.
8)
Do  not  touch  the  power  plug,  insert  a  telephone  line  jack  or
network  jack,  operate  the  machine,  or  service  the  machine
with wet or oily hands.
It may cause an electric shock.
C. Note for installing site
Do not install the machine at the following sites.
1)
Places  of  high  temperature,  high  humidity,  low  tempera-
ture, low humidity, places of extreme change in tempera-
ture and humidity.
Paper  may  get  damp  and  form  moisture  inside  the  machine,
causing paper jam or poor copy quality.
For operating and storing conditions, refer to the specifications
described later.
2)
Place of high vibrations
It may cause a breakdown.
WARNING:  If this WARNING should be ignored, a serious 
danger to life or a serious injury could result.
CAUTION:   If this CAUTION should be ignored, an injury or 
damage to property could result.
CAUTION
DOUBLE POLE/NEUTRAL FUSING
Page of 127