MX-M1205  MX-M1055/M1205 (MAIN UNIT)  2 – 10
4) Fix  Arm  Cover  Bottom  (item  No,16)  with  1pc  of  screw.  (Item
No.10 / M4×8 S-Tite).
Hook  the  pawl-shaped  items  on  the  metal  plate  of
the opponent side. (3 positions)
*Slide the cabinet from upper downward and hook the pawls to
assemble.
5) Fix Upper Cabinet Right Upper with 4pcs of screws. (Use the
screw (1) M4x8 S-Tite which is originally fixed)
6)
Fix Glass Fixer Right with 2pcs of screws. (Use the screw (2)
M4x6: XBTS740P06000 which is originally fixed)
7)
Fix Right Cabinet Rear Middle (item No,15) with 1pc of screw.
(Item No.10 / M4×8 S-Tite)
Hook  the  pawl-shaped  items  on  the  holes  of  the
opponent side. (4 positions)
*Slide the cabinet from upper downward and hook to assem-
ble.
Ĭ
Ĭ
Ĭ
Ĭ
ĭ
ĭ
Glass
 fixer right
Upper Cabinet Right Upper
MX-M1205  MX-M1055/M1205 (MAIN UNIT)  2 – 11
Attach the operation panel
1) Install the Panel arm (Packed item No.2) by fixing the screws
(2: Packed item No.11, 3: Packed item No.10).
2) Put the Arm cover (Packed item No.3) temporarily as the figure
below.
3) Install  the  Panel  (Packed  item  No.4)  by  fixing  the  screws
(Packed item No.10).
4)
Arrange the wire and fix the screw as the figure below.
Handle  the  connectors  with  care  not  to  make dam-
age to the connector when connecting.
Connect the connectors vertically to the PWB.
When arranging the cable, never twist it.
Handle  the  connectors  with  care  not  to  make dam-
age to the connector by snagging them when wiring.
Attach the bands of the harness of Operation Panel on the arm
(3 positions)
ĭ
Į
Take out the harness for Operation Panel 
from the packing.
MX-M1205  MX-M1055/M1205 (MAIN UNIT)  2 – 12
Attach  the  bands  of  the  harness  for  Operation  Panel  to  the
arm. (2 positions)
5)  Install the Arm cover (Packed item No.5) by fixing the screws
(Packed item No.10).
6)
Install  the  Upper  arm  cover  (Packed  item  No.7)  by  fixing  the
screws (Packed item No.14).
7)
Install the Arm cover by fixing the screws (Packed item No.14).
8)
Turn the operation panel to make the cabinet line straight and
Install the Arm cover R (Packed item No.7) as the figure below.
Fasten with earth terminal. 
Fasten the earth line with screws.
Attach the bands of the harness for 
Operation Panel to the arm. (2 positions)
Put the harness for Operation Panel 
through the hole.
Connect the connectors. 
(4 positions)
MX-M1205  MX-M1055/M1205 (MAIN UNIT)  2 – 13
9) Install  the  Upper  arm  cover  (Packed  item  No.8)  by  fixing  the
screw  (Packed  item  No.10)  and  attach  the  screw  cover
(Packed item No.9).
10) Install the Arm lower cover F (Packed item No.17) as the figure
below.
Hook  the  pawl-shaped  items  on  the  holes  of  the
opponent side. (2 positions)
11) Install the Arm lower cover R (Packed item No.18) by fixing the
screw (Packed item No.10).
Fit the rib-shaped item to the groove of the opponent
side. (2 positions)
12) Attach Upper Cabinet Front Right with 5pcs of screws.
 ((1) 2pcs of M3x6 machine screws, (2) 1pc of M3x10 P-Tite
screw, (3) 2pcs of M4x8 machine screw (black) which are fixed
originally.)
Ĭ
Ĭ
ĭ
Į
Į
Page of 127
Display