Sharp AR-M351U / AR-M451U (serv.man17) Service Manual ▷ View online

AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 86
Operation/Procedure
(Display message)
Operation/Procedure
1) Enter the number corresponding to the select IN signal YES/
NO setting with 10-key.
2) Press [START] key.
When the printer parallel I/F is used and a trouble is generated in
the communication between the PC and the printer, change the
setting of this simulation.
Operation/Procedure
During check, "CHECKING" is displayed. When check is com-
pleted normally, "OK" is displayed. In case of an error, "NG" is dis-
played.
(Display message)
67
67-2
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the parallel I/F of 
the printer. (This simulation is for production only, 
and requires a special tool for execution. Not used 
in the market.)
Section
MFP controller
Item
Operation
Interface/Communication
WAITING
Waiting
READY
Check start OK
OK
Check end (Normal)
STAGE*NG
Check end (Error in stage *.  *: 1 - 11)
lWith READY displayed, 
press [START] key.
Press [CUSTOM SETTINGS] key.
67-11
Purpose
Setting
Function
(Purpose)
Used to set YES/NO of the parallel I/F select 
signal of the printer.
Section
MFP controller
Item
Operation
Interface/Communication
Item
Default
0
OFF
1
1
ON
SIMULATION 67-2
CENTRO PORT CHECK.
CENTRO PORT: 
READY
SIMULATION 67-2
CENTRO PORT CHECK.
CENTRO PORT:    
OK
 (or 
STAGE7 NG
)
SIMULATION 67-11
CENTRO SELECT IN SIGNAL SETTING. SELECT 0-1, AND PRESS
START.
0. OFF
1. ON
67-16
Purpose
Operation test/Check
Function
(Purpose)
Used to check the operation of the network card.
Section
MFP controller
Item
Operation
Interface/Communication
CHECKING
Checking
OK
Check end (Normal)
NG
Check end (Error)
Check end
Press [CUSTOM SETTINGS] key.
SIMULATION 67-16
NETWORK INTERFACE CARD CHECK.
NIC: CHECKING
SIMULATION 67-16
NETWORK INTERFACE CARD CHECK.
NIC: OK (or NG)
AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 87
3. Other related items
(1) Simulation adjustment value/ Set value data
Each controller is provided with an EEPROM. The adjustment/set
values are collected to the MFP controller. If they are changed,
they are sent back and saved.
Data saved by the PCU PWB
MFP
CONTROLLER
ENGINE 
CONTROLLER
SCANNER 
CONTROLLER
LCD
Saved adjustment value send 
(When the power is turned on, etc.)
When the value is changed, 
it is sent and saved.
Counters
Adjustment value
Other
Drum rotation time counter 
(Accumulated time)
Developing bias voltage value
Serial number
Developer unit rotation time 
counter
Cleaning mode developing bias voltage value
Trouble history
Toner supply time (Block IC CHIP)
Main high voltage adjustment
Tray 1 size
Drum rotating time (Block IC 
CHIP)
Transfer charger voltage value
LCC size
Total counter
Transfer belt cleaning voltage value
Manual destination information
Maintenance counter
Toner concentration reference value
Developing counter
Density correction start set time (Developer unit)
Tray 2 destination information
Drum counter
Density correction rotation time (Developer tank)
Toner cartridge counter
Density correction amount (Developer tank)
Tray 1 paper remaining quantity data
Valid paper counter
Correction execution direction, upper/lower limit 
(Developer tank)
Tray 2 paper remaining quantity data
Tray 1 paper feed counter
Toner concentration temperature correction (low 
temperature side) correction amount
Tray 3 paper remaining quantity data
Tray 2 paper feed counter
Toner concentration temperature correction (low 
temperature side) set temperature
Tray 4 paper remaining quantity data
Tray 3 paper feed counter
Toner concentration temperature correction (low 
temperature side) release temperature
Final toner concentration sensor output value
Tray 4 paper feed counter
Toner concentration temperature correction (high 
temperature) correction amount
Toner cartridge IC CHIP destination
Manual paper feed counter
Toner concentration temperature correction (high 
temperature side) judgment temperature
Counter mode setting
ADU paper feed counter
Toner concentration temperature correction (high 
temperature side) judgment voltage
White paper exit count setting
Staple counter
Toner concentration temperature correction (high 
temperature side) correction value
Trouble memory mode setting
Punch counter
Toner concentration temperature correction (low 
temperature side) release time
Fusing operation mode (Prevention against 
curl)
Main unit right-side paper exit 
counter
Toner concentration temperature correction (high 
temperature side) toner concentration delay time 
CE mark conforming operation mode
Multi-purpose width adjustment value
Maintenance cycle
Manual width adjustment value
Print stop setting when developer life over
Saddle staple counter
Heater lamp temperature (Center, normal control)
Saddle alignment operation priority mode
Lead edge adjustment
PCU SOFT SW
Led edge void set value
Rear edge void set value
Side edge setting
Print off-center adjustment value
Resist amount adjustment value
Laser power adjustment value
PPD1 sensor adjustment
Process correction inhibit allow set value
Developing bias rising correction wait time
Developing bias rising correction adjustment value
Built-in finisher jogger position adjustment
Saddle adjustment value
AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 88
Data saved by the scanner control PWB
Data saved by the MFP control PWB
Counters
Adjustment value
Other
Scan counter
Document lead edge adjustment value
Exposure mode set value
SPF paper pass counter
Document off-center adjustment value
Scanner serial number
SPF stamp counter
Document image loss amount adjustment value
Document image loss amount adjustment value
Magnification ratio adjustment value
Scanner soft SW
SPF resist amount adjustment value
Exposure motor speed adjustment value
Platen document detection adjustment value
SPF size width detection adjustment value
Touch panel adjustment value
Exposure level adjustment value
ϒ
 change value
OC/SPF exposure correction value
Shading adjustment value (CCD/CIS)
CCD shading start position adjustment value
Counters
Adjustment value
Other
Copy counter
FAX SOFT SW., etc.
Trouble history
Printer counter
JAM history
FAX receive counter
Destination setting
FAX send counter
Language setting
All valid paper counter
Toner save mode setting 
Trouble counter
13" setting
JAM counter
Auditor setting
Counter mode setting
Trouble memory mode setting
Center binding mode AMS setting
PC/MODEM communication trouble detection 
YES/NO setting
Tag number set value
Printers set values
Network set value
MFP soft SW
AR-M351U/M451U, AR-M355U/M455U  SIMULATION  9 - 88
Data saved by the scanner control PWB
Data saved by the MFP control PWB
Counters
Adjustment value
Other
Scan counter
Document lead edge adjustment value
Exposure mode set value
SPF paper pass counter
Document off-center adjustment value
Scanner serial number
SPF stamp counter
Document image loss amount adjustment value
Document image loss amount adjustment value
Magnification ratio adjustment value
Scanner soft SW
SPF resist amount adjustment value
Exposure motor speed adjustment value
Platen document detection adjustment value
SPF size width detection adjustment value
Touch panel adjustment value
Exposure level adjustment value
ϒ
 change value
OC/SPF exposure correction value
Shading adjustment value (CCD/CIS)
CCD shading start position adjustment value
Counters
Adjustment value
Other
Copy counter
FAX SOFT SW., etc.
Trouble history
Printer counter
JAM history
FAX receive counter
Destination setting
FAX send counter
Language setting
All valid paper counter
Toner save mode setting 
Trouble counter
13" setting
JAM counter
Auditor setting
Counter mode setting
Trouble memory mode setting
Center binding mode AMS setting
PC/MODEM communication trouble detection 
YES/NO setting
Tag number set value
Printers set values
Network set value
MFP soft SW
Page of 88
Display

Sharp AR-M351U / AR-M451U (serv.man17) Service Manual ▷ Download