Panasonic KV-S5055C (serv.man2) Service Manual ▷ View online
65
8.5.4.
FAN
8.5.5.
Micro Switch
1. Remove the Right Cover (with Right Front Cover). (See 8.5.1.)
2. Remove the 2 screws.
3. Disconnect the connector from the POWER Board.
1. Remove the Right Cover (with Right Front Cover). (See 8.5.1.)
2. Disconnect the connector.
3. Remove the 2 screws and the Micro Switch.
66
8.5.6.
Power Box
1. Remove the 2 screws from the front right of the scanner.
2. Remove the screw (a) and 2 screws (b) from the back right of
the scanner. Then pull off the Power Box.
the scanner. Then pull off the Power Box.
3. Disconnect the 2 connectors to release the Power Box from
the scanner.
the scanner.
67
8.5.7.
POWER Board
8.5.8.
Ionizer Board
1. Remove the Power Box. (See 8.5.6.)
2. Remove the 5 screws that fasten the Power Box Cover to the
Power Box.
Power Box.
3. Remove the 7 screws on the POWER Board.
4. Remove the 3 screws that fasten the Heatsink to the side of
the Power Box.
the Power Box.
5. Disconnect the 3 connectors.
6. Pull the POWER Board from the Power Box.
1. Remove the Power Box. (See 8.5.6.)
2. Remove the 2 screws.
3. Disconnect the 2 connectors to release the Ionizer Board's
unit from the scanner.
unit from the scanner.
68
4. While releasing the holder’s 3 claws, pull out the Ionizer
Board.
Board.
Click on the first or last page to see other KV-S5055C (serv.man2) service manuals if exist.