Panasonic KV-S5055C (serv.man2) Service Manual ▷ View online
53
8.4.6.
Reference Plate (B)
1. Remove the Light Unit (F). (See 8.4.3.)
2. Remove the 2 springs (1 from each side of the Reference
Plate (B)).
Plate (B)).
Disassembling Note: How to remove springs
Make sure to release one side of the spring hook while
holding the other side of the spring hook not to lose the
spring.
holding the other side of the spring hook not to lose the
spring.
54
3. Release the 2 poly-sliders that hold the Reference Plate (B) on
both sides.
both sides.
4. Remove the Gear and poly-slider.
5. Slide and remove the plate.
Reassembling Note: How to attach the spring
1. With one side of the spring hung to a wire (about 3 inches
long), reassemble the spring around the Reference
Plate (B).
long), reassemble the spring around the Reference
Plate (B).
2. Pass the wire behind the bearing for the plate.
3. Hook one side of spring while pulling the other side of the
wire. Then, hook the other side of the spring.
4. Remove the wire.
wire. Then, hook the other side of the spring.
4. Remove the wire.
55
8.4.7.
Inner Cover T
8.4.8.
Top Cover
1. Push the ADF Door Release to open the ADF Door.
2. Remove the screw.
3. Pull out and remove the Inner Cover T.
1. Remove the Inner Cover T. (See 8.4.7.)
2. Remove the 2 screws.
3. Open the Imprinter Door, and then remove the 2 screws.
4. Remove the Top Cover.
56
8.4.9.
BENT RELAY Board
8.4.10. USS / WAITING SENSOR Board
8.4.11. BENT PAPER S (R) Board and BENT PAPER R (R) Board
1. Remove the Imprinter Door. (See 8.3.1.)
2. Remove the Top Cover. (See 8.4.8.)
3. Release the 2 connectors from the clampers.
4. Disconnect the 5 connectors to the BENT RELAY Board.
5. Remove the 2 screws on the BENT RELAY Board.
1. Remove the Imprinter Door. (See 8.3.1.)
2. Remove the Top Cover. (See 8.4.8.)
3. Remove the screw on the USS / WAITING SENSOR Board.
4. Disconnect the connector to the USS / WAITING SENSOR
Board.
Board.
1. Remove the Imprinter Door. (See 8.3.1.)
2. Remove the Top Cover. (See 8.4.8.)
3. Remove the spring to release the Lock Assembly from the
scanner.
scanner.
4. Remove the Lock Assembly.