49
Feed
1. Set documents on the Feed Tray.
2. Click "Feed" on the test menu.
3. Set "Test Condition" depending on each scanning 
condition.
4. Click "START" to start the test.
5. Click "OK" after the test.
6. Click "Close" to return to the test menu.
Sleep Mode
1. Click "Sleep mode" on the test menu.
2. Click "START" to enter the sleep mode.
3. Click "STOP" to return from the sleep mode.
4. Click "Close" to return to the test menu. 
CIS LED
1. Click "CIS LED" on the test menu.
2. Open ADF door.
3. Select a Lamp color. (RGB, R, G, B)
4. Click "START".
Whenever clicking "START", the lighting state of the LED 
changes as follows. front LED > back LED > both LEDs > off
5. Click "STOP" to stop the test.
6. Click "Close" to return to the test menu. 
Item
Operation
Default
Remarks
50
**Focus
1. Click "Focus" on the test menu.
2. Open the ADF Door, and then place a clean white paper(A4 
(80 g/m
2
),or Letter (20lb.)) between the Scanning Glass (F) 
and Scanning Glass (B).
Then, close the ADF Door.
3. Select a side (Front or Back) resolution. (300dpi or 600dpi)
4. Set the value of Gain.(Value:0 to 255)
5. As required, set "Shading Correction" by checking check 
box so that the image sensor output-level after Shading 
Correction can be seen.
6. Click "START" to monitor the image sensor waveform of the 
white paper. Refer to Remark's table.
7. Click "STOP".
8. Remove the white paper.
9. Click "START" to monitor the image sensor waveform of the 
black background. Refer to Remark's table.
10. Click "STOP".
11. Click "Close" to return to the test menu.
Note
This operation indicates a 
sensor output waveform.
If the waveform has any 
partial depression or uplift, 
clean the Scanning Glass (F) 
or Scanning Glass (B).
If the waveform rises overall 
with black background or 
drops overall with white 
paper, check followings.
a. LED lights of CIS
b. The positioning of the 
Background Plate.
c. The output signal of CIS
Output Level
Item
Operation
Default
Remarks
Scanning Image : White Paper, Shading Correction :ON
Scanning Image : White Paper, Shading Correction :ON 
Scanning Image : Black Background, Shading Correction :ON 
Back ground Color
Shading Correction
Good Result
     (Level)
50 or more
around 0
Black
 ON
White
 ON
51
Double Feed 
1. Click "Double feed" on the test menu.
2. Set "Send Level".
3. Open the ADF Door. And hold a piece of clean white paper 
between Double feed detector (G) and (R), and then close 
the ADF Door.
4. Click "START" to start the double feed sensor's sensitivity 
test.
5. Check whether the peak level is within the specification. (See 
Remarks.)
6. Click "STOP" to finish this test.
7. Open the ADF Door. And remove the white paper, and then 
close the ADF Door.
8. Click "Close" to return to the test menu. 
Memory
1. Click "Memory" on the test menu.
2. Click "START" to start Memory Read / Write Test.
3. Check the result.
4. Click "Close" to return to the test menu.
Item
Operation
Default
Remarks
Send Level
Good Result
     (Level)
700 or more
 Level: 110
Send Level
Good Result
(Peak Level)
Confirm the peak 
level increases 
according to the 
increment of the 
intensity level.

(Go up the value 
  step by step)
52
10.3.8. Adjustment
Item
Operation
Default
Remarks
Shading
1. Click "Shading" on the adjust menu.
2. Set the resolution (300dpi, 600dpi) and click "OK".
3. Clean the conveyor, rollers, Scanning Glass (F) and (B) 
according to the message on the display. And click "OK".
4. Set Shading Sheet (Part No.: PNZXS1037AM) on the Feed 
Tray.
5. Click "OK" to start the adjustment.
6. After "Finished Adjusting" message, click "OK" to return to 
the adjust menu.
Until this process is
completed, don’t stop the
process by opening any
doors or turning off the
scanner. 
Shading data
1. Click "Shading data" on the adjust menu.
2. Click "Get Shading Data".
3. Save it to selected folder.
4. Click "OK" to return to the adjust menu.
This data file is used for 
analysis. 
All Position
1. Set 2 pcs of test chart A (Part No.: PBQX90095Z-J) on the 
Feed Tray.
2. Click "All position" on the adjust menu to execute scanning 
position and length adjustment.
3. Check the result.
4. Click "OK" to return to the adjust menu.
Set 2 pcs of test chart A on
the Feed Tray in order. 
1st page: Front side 
2nd page: Back side
Individual Position 1. Adjust Automatically.
a. Set test chart A (Part No.:PBQX90095Z-J) on the Feed 
Tray.
b. Click "Individual position" on the adjust menu.
c. Click one of 6 "Adjust Automatically" buttons to execute 
the adjustment.
d. Check the result.
e. Click "OK" to finish the adjustment.
f. Click "OK" to return to the adjust menu.
2. Adjust Manually.
a. Click "Individual position" on the adjust menu.
b. Change the parameters (mm, %) as required. (Refer to 
Remarks.)
c. Click "OK" to renew the setting, and to return to the adjust 
menu.
1. Adjust Automatically Auto. 
adjustments items
1) Length
2) Paper End Position
3) Front V. Position
4) Front H. Position
5) Back V. Position
6) Back H. Position
2. Adjust Manually
(Length)
+: Increasing the value allows 
the scanned image to 
extend vertically.
(Paper End Position)
+: On the Length Control 
mode, increasing the value 
allows the paper-end 
timing to be earlier.
(Vertical Position)
+: Increasing the value shifts 
the scanned image 
position downward.
(Horizontal Position)
+: Increasing the value shifts 
the scanned image 
position to the right.
Note
If the appropriate scanning 
position cannot be obtained 
by any of the manual 
adjustments, check CIS 
installation.
Page of 127
Display

Click on the first or last page to see other KV-S1037 / KV-S1038 / KV-S1026C-M2 / KV-S1026C-J2 service manuals if exist.