JBL VOYAGER (serv.man5) EMC - CB Certificate ▷ View online
Report No.: SF201300640
Page 17 of 68
EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
Rated current (A), type, nominal thread diameter
(mm) ...................................................................... :
(mm) ...................................................................... :
⎯
3.3.6
Wiring terminal design
N/A
3.3.7
Grouping of wiring terminals
N/A
3.3.8 Stranded
wire
N/A
3.4
Disconnection from the mains supply
The unit supplied by DC 19V; also evluated in approved adaper
N/A
3.4.1 General
requirement
N/A
3.4.2 Disconnect
devices
N/A
3.4.3
Permanently connected equipment
N/A
3.4.4
Parts which remain energized
N/A
3.4.5
Switches in flexible cords
N/A
3.4.6
Number of poles - single-phase and d.c. equipment
N/A
3.4.7
Number of poles - three-phase equipment
N/A
3.4.8
Switches as disconnect devices
N/A
3.4.9
Plugs as disconnect devices
N/A
3.4.10 Interconnected
equipment
N/A
3.4.11
Multiple power sources
N/A
3.5
Interconnection of equipment
P
3.5.1 General
requirements
Considered.
P
3.5.2
Types of interconnection circuits ........................... : Interconnection circuits are
SELV circuits
P
3.5.3
ELV circuits as interconnection circuits
No ELV interconnection
circuits
circuits
N/A
3.5.4
Data ports for additional equipment
No data ports.
N/A
4 PHYSICAL
REQUIREMENTS
P
4.1 Stability
N/A
Angle of 10
°
N/A
Test force (N) ........................................................ :
N/A
4.2 Mechanical
strength
Class III device, no hazardous voltage/energy inside
N/A
4.2.1 General
N/A
Rack-mounted equipment.
N/A
4.2.2
Steady force test, 10 N
N/A
4.2.3
Steady force test, 30 N
N/A
4.2.4
Steady force test, 250 N
N/A
Report No.: SF201300640
Page 18 of 68
EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
4.2.5 Impact
test
N/A
Fall
test
N/A
Swing
test
N/A
4.2.6
Drop test; height (mm) .......................................... :
N/A
4.2.7
Stress relief test
N/A
4.2.8
Cathode ray tubes
N/A
Picture tube separately certified ............................ :
N/A
4.2.9
High pressure lamps
N/A
4.2.10
Wall or ceiling mounted equipment; force (N) ....... :
N/A
4.3
Design and construction
P
4.3.1
Edges and corners
All edges and corners are
rounded and/or smoothed.
rounded and/or smoothed.
P
4.3.2
Handles and manual controls; force (N) ............. :
N/A
4.3.3 Adjustable
controls
No hazardous adjustable
controls.
controls.
N/A
4.3.4
Securing of parts
Electrical and mechanical
connections can be expected
to withstand usual mechanical
stress.
connections can be expected
to withstand usual mechanical
stress.
P
4.3.5
Connection by plugs and sockets
P
4.3.6
Direct plug-in equipment
Not intended to plug directly
into a wall socket-outlet.
into a wall socket-outlet.
N/A
Torque
..................................................................
:
⎯
Compliance with the relevant mains plug standard
.............................................................................. :
.............................................................................. :
N/A
4.3.7
Heating elements in earthed equipment
No heating elements
provided.
provided.
N/A
4.3.8 Batteries
See
below
P
- Overcharging of a rechargeable battery
(see appended table 4.3.8)
P
- Unintentional charging of a non-rechargeable
battery
battery
N/A
- Reverse charging of a rechargeable battery
According to the
configuration, battery can't be
reversed charging.
configuration, battery can't be
reversed charging.
N/A
- Excessive discharging rate for any battery
(see appended table 4.3.8)
P
4.3.9
Oil and grease
Insulation in intended use not
considered to be exposed to
oil or grease.
considered to be exposed to
oil or grease.
N/A
4.3.10
Dust, powders, liquids and gases
The equipment does not
produce dust or use powders,
liquids and gases in the
equipment.
produce dust or use powders,
liquids and gases in the
equipment.
N/A
4.3.11
Containers for liquids or gases
No container for liquids or
gases used
gases used
N/A
Report No.: SF201300640
Page 19 of 68
EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
4.3.12
Flammable liquids ................................................ :
The equipment does not
contain flammable liquid
contain flammable liquid
N/A
Quantity of liquid (l) .............................................. :
N/A
Flash point (
°C) .................................................... :
N/A
4.3.13 Radiation
Refer
below:
P
4.3.13.1 General
Refer
below:
P
4.3.13.2
Ionizing radiation
The equipment does not
generate ionizing radiation.
generate ionizing radiation.
N/A
Measured radiation (pA/kg) .................................. :
⎯
Measured
high-voltage (kV) ................................. :
⎯
Measured focus voltage (kV) ............................... :
⎯
CRT markings ...................................................... :
⎯
4.3.13.3
Effect of ultraviolet (UV) radiation on materials
The equipment does not
produce significant UV
radiation.
produce significant UV
radiation.
N/A
Part, property, retention after test, flammability
classification ......................................................... :
classification ......................................................... :
N/A
4.3.13.4
Human exposure to ultraviolet (UV) radiation ...... :
The equipment does not
produce significant UV
radiation.
produce significant UV
radiation.
N/A
4.3.13.5
Lasers (including laser diodes) and LEDs
P
4.3.13.5.1 Lasers
(including laser diodes)
N/A
Laser
class
...........................................................
:
⎯
4.3.13.5.2 Light emitting diodes (LEDs)
LED indicating lights
P
4.3.13.6
Other types ........................................................... :
The equipment does not
generate other types of
radiation.
generate other types of
radiation.
N/A
4.4
Protection against hazardous moving parts
N/A
4.4.1 General
No hazardous moving parts
within the equipment
within the equipment
N/A
4.4.2
Protection in operator access areas .................... :
N/A
Household and home/office document/media
shredders
shredders
N/A
4.4.3
Protection in restricted access locations .............. :
N/A
4.4.4
Protection in service access areas
N/A
4.4.5
Protection against moving fan blades
N/A
4.4.5.1 General
N/A
Not considered to cause pain or injury. a)……….:
N/A
Is considered to cause pain, not injury. b) ………:
N/A
Considered to cause injury. c) ………:
N/A
Report No.: SF201300640
Page 20 of 68
EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
4.4.5.2
Protection for users
N/A
Use of symbol or warning …………………………:
N/A
4.4.5.3
Protection for service persons
N/A
Use of symbol or warning …………………………:
N/A
4.5 Thermal
requirements
P
4.5.1
General
See appended table 4.5.1
P
4.5.2
Temperature tests
(see appended table 4.5)
P
Normal load condition per Annex L ...................... :
⎯
4.5.3
Temperature limits for materials
(see appended table 4.5)
P
4.5.4
Touch temperature limits
(see appended table 4.5)
P
4.5.5 Resistance
to
abnormal heat ............................... :
N/A
4.6 Openings
in
enclosures
P
4.6.1
Top and side openings
No any opening
P
Dimensions (mm) ................................................. :
⎯
4.6.2
Bottoms of fire enclosures
No any opening
P
Construction of the bottomm, dimensions (mm) .. :
⎯
4.6.3
Doors or covers in fire enclosures
No doors or covers.
N/A
4.6.4
Openings in transportable equipment
Not transportable equipment.
N/A
4.6.4.1
Constructional design measures
N/A
Dimensions (mm) ................................................. :
⎯
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
No barrier secured by
adhesive inside enclosure.
adhesive inside enclosure.
N/A
Conditioning temperature (
°C), time (weeks) ........ :
⎯
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
Method 1: Selection and
application of components
and materials that minimize
the possibility of ignition and
spread of flame
application of components
and materials that minimize
the possibility of ignition and
spread of flame
P
Method 1, selection and application of components
wiring and materials
wiring and materials
Selection and application of
components, wiring and
materials, which reduce the
possibility of ignition and
spread of flame by the use of
fire enclosure (see appended
critical component table)
components, wiring and
materials, which reduce the
possibility of ignition and
spread of flame by the use of
fire enclosure (see appended
critical component table)
P
Click on the first or last page to see other VOYAGER (serv.man5) service manuals if exist.