DOWNLOAD JBL VOYAGER (serv.man5) Service Manual ↓ Size: 2.51 MB | Pages: 68 in PDF or view online for FREE

Model
VOYAGER (serv.man5)
Pages
68
Size
2.51 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
voyager-sm5.pdf
Date

JBL VOYAGER (serv.man5) EMC - CB Certificate ▷ View online

Report No.: SF201300640 
Page 17 of 68
EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
 
Rated current (A), type, nominal thread diameter 
(mm)  ...................................................................... :
 
⎯ 
3.3.6 
Wiring terminal design 
 
N/A 
3.3.7 
Grouping of wiring terminals 
 
N/A 
3.3.8 Stranded 
wire 
 
N/A 
 
 
 
 
3.4 
Disconnection from the mains supply 
The unit supplied by DC 19V; also evluated in approved adaper 
N/A 
3.4.1 General 
requirement 
 
N/A 
3.4.2 Disconnect 
devices 
 
N/A 
3.4.3 
Permanently connected equipment 
 
N/A 
3.4.4 
Parts which remain energized 
 
N/A 
3.4.5 
Switches in flexible cords 
 
N/A 
3.4.6 
Number of poles - single-phase and d.c. equipment  
N/A 
3.4.7 
Number of poles - three-phase equipment 
 
N/A 
3.4.8 
Switches as disconnect devices 
 
N/A 
3.4.9 
Plugs as disconnect devices 
 
N/A 
3.4.10 Interconnected 
equipment 
 
N/A 
3.4.11 
Multiple power sources 
 
N/A 
 
3.5 
Interconnection of equipment 
3.5.1 General 
requirements 
Considered. 
3.5.2 
Types of interconnection  circuits   ........................... : Interconnection circuits are 
SELV circuits 
3.5.3 
ELV circuits as interconnection circuits  
No ELV interconnection 
circuits 
N/A 
3.5.4 
Data ports for additional equipment 
No data ports. 
N/A 
 
4 PHYSICAL 
REQUIREMENTS 
4.1 Stability 
N/A 
 
Angle of 10
° 
 N/A 
 
Test force (N)  ........................................................ :  
N/A 
 
4.2 Mechanical 
strength 
Class III device, no hazardous voltage/energy inside 
N/A 
4.2.1 General 
 
N/A 
 
Rack-mounted equipment.  
 
N/A 
4.2.2 
Steady force test, 10 N 
 
N/A 
4.2.3 
Steady force test, 30 N 
 
N/A 
4.2.4 
Steady force test, 250 N 
 
N/A 
Report No.: SF201300640 
Page 18 of 68
EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
4.2.5 Impact 
test 
 
N/A 
 Fall 
test 
 
N/A 
 Swing 
test 
 
N/A 
4.2.6 
Drop test; height (mm)  .......................................... :  
N/A 
4.2.7 
Stress relief test 
 
N/A 
4.2.8 
Cathode ray tubes 
 
N/A 
 
Picture tube separately certified  ............................ :  
N/A 
4.2.9 
High pressure lamps 
 
N/A 
4.2.10 
Wall or ceiling mounted equipment; force (N)  ....... :  
N/A 
 
4.3 
Design and construction  
4.3.1 
Edges and corners 
All edges and corners are 
rounded and/or smoothed. 
4.3.2 
Handles and manual controls; force (N) ............. : 
 
N/A 
4.3.3 Adjustable 
controls 
 
No hazardous adjustable 
controls. 
N/A 
4.3.4 
Securing of parts 
Electrical and mechanical 
connections can be expected 
to withstand usual mechanical 
stress. 
4.3.5 
Connection by plugs and sockets 
 
4.3.6 
Direct plug-in equipment 
Not intended to plug directly 
into a wall socket-outlet. 
N/A 
 Torque 
 
.................................................................. 
:
 
 
 
Compliance with the relevant mains plug standard 
 .............................................................................. :
 N/A 
4.3.7 
Heating elements in earthed equipment 
No heating elements 
provided. 
N/A 
4.3.8 Batteries 
See 
below 
 
- Overcharging of a rechargeable battery 
(see appended table 4.3.8) 
 
- Unintentional charging of a non-rechargeable 
battery 
 N/A 
 
- Reverse charging of a rechargeable battery 
According to the 
configuration, battery can't be 
reversed charging. 
N/A 
 
- Excessive discharging rate for any battery 
(see appended table 4.3.8) 
4.3.9 
Oil and grease 
Insulation in intended use not 
considered to be exposed to 
oil or grease. 
N/A 
4.3.10 
Dust, powders, liquids and gases 
The equipment does not 
produce dust or use powders, 
liquids and gases in the 
equipment. 
N/A 
4.3.11 
Containers for liquids or gases 
No container for liquids or 
gases used 
N/A 
Report No.: SF201300640 
Page 19 of 68
EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
4.3.12 
Flammable liquids  ................................................ :
The equipment does not 
contain flammable liquid 
N/A 
 
Quantity of liquid (l)  .............................................. :
 
N/A 
 
Flash point (
°C)  .................................................... :  
N/A 
4.3.13 Radiation 
Refer 
below: 
4.3.13.1 General 
Refer 
below: 
4.3.13.2 
Ionizing radiation  
The equipment does not 
generate ionizing radiation. 
N/A 
 
Measured radiation (pA/kg)  .................................. :
 
 
 Measured 
high-voltage (kV)  ................................. :
 
 
 
Measured focus voltage (kV)  ............................... :
 
 
 
CRT markings  ...................................................... :
 
 
4.3.13.3 
Effect of ultraviolet (UV) radiation on materials 
The equipment does not 
produce significant UV 
radiation. 
N/A 
 
Part, property, retention after test, flammability 
classification  ......................................................... :
 N/A 
4.3.13.4 
Human exposure to ultraviolet (UV) radiation  ...... :
The equipment does not 
produce significant UV 
radiation. 
N/A 
4.3.13.5 
Lasers (including laser diodes) and LEDs 
 
4.3.13.5.1 Lasers 
(including laser diodes) 
 
N/A 
 Laser 
class 
 
........................................................... 
:
 
⎯ 
4.3.13.5.2  Light emitting diodes (LEDs) 
LED indicating lights 
4.3.13.6 
Other types  ........................................................... :
The equipment does not 
generate other types of 
radiation. 
N/A 
 
4.4 
Protection against hazardous moving parts 
N/A 
4.4.1 General 
No hazardous moving parts 
within the equipment 
N/A 
4.4.2 
Protection in operator access areas  .................... :
 
N/A 
 
Household and home/office document/media 
shredders 
 N/A 
4.4.3 
Protection in restricted access locations  .............. :
 
N/A 
4.4.4 
Protection in service access areas 
 
N/A 
4.4.5 
Protection against moving fan blades 
 
N/A 
4.4.5.1 General 
 
N/A 
 
Not considered to cause pain or injury. a)……….: 
 
N/A 
 
Is considered to cause pain, not injury. b) ………: 
 
N/A 
 
Considered to cause injury.                   c) ………:    
N/A 
Report No.: SF201300640 
Page 20 of 68
EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
4.4.5.2 
Protection for users 
 
N/A 
 
Use of symbol or warning …………………………: 
 
N/A 
4.4.5.3 
Protection for service persons 
 
N/A 
 
Use of symbol or warning …………………………: 
 
N/A 
 
4.5 Thermal 
requirements 
4.5.1 
General 
See appended table 4.5.1 
4.5.2 
Temperature tests 
(see appended table 4.5) 
 
Normal load condition per Annex L  ...................... :
 
 
4.5.3 
Temperature limits for materials 
(see appended table 4.5) 
4.5.4 
Touch temperature limits 
(see appended table 4.5) 
4.5.5 Resistance 
to 
abnormal heat  ............................... :
 
N/A 
 
4.6 Openings 
in 
enclosures 
4.6.1 
Top and side openings 
No any opening 
P 
 
Dimensions (mm)  ................................................. :
 
 
4.6.2 
Bottoms of fire enclosures 
No any opening 
 
Construction of the bottomm, dimensions (mm)  .. :
 
⎯ 
4.6.3 
Doors or covers in fire enclosures 
No doors or covers. 
N/A 
4.6.4 
Openings in transportable equipment 
Not transportable equipment. 
N/A 
4.6.4.1 
Constructional design measures 
 
N/A 
 
Dimensions (mm)  ................................................. :
 
⎯ 
4.6.4.2 
Evaluation measures for larger openings 
 
N/A 
4.6.4.3 
Use of metallized parts 
 
N/A 
4.6.5 
Adhesives for constructional purposes 
No barrier secured by 
adhesive inside enclosure. 
N/A 
 
Conditioning temperature (
°C), time (weeks) ........ :
 
 
 
4.7 
Resistance to fire 
P
 
4.7.1 
Reducing the risk of ignition and spread of flame 
Method 1: Selection and 
application of components 
and materials that minimize 
the possibility of ignition and 
spread of flame 
 
Method 1, selection and application of components 
wiring and materials 
Selection and application of 
components, wiring and 
materials, which reduce the 
possibility of ignition and 
spread of flame by the use of 
fire enclosure (see appended 
critical component table) 
Page of 68
Display