Report No.: SF201300640 
Page 13 of 68
EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
2.10 
Clearances, creepage distances and distances through insulation 
Class III device, no hazardous voltage inside; also evaluated in approved adapter 
2.10.1 
General  
See below.  
2.10.1.1 Frequency 
 
............................................................. 
:  
N/A 
2.10.1.2 Pollution 
degrees 
 
.................................................. : Pollution Degree 2. 
2.10.1.3 
Reduced values for functional insulation 
The functional insulation 
complied with clause 5.3.4 
2.10.1.4 Intervening 
unconnected conductive parts 
 
N/A 
2.10.1.5 
Insulation with varying dimensions 
 
N/A 
2.10.1.6 Special 
separation 
requirements 
 
N/A 
2.10.1.7 
Insulation in circuits generating starting pulses 
 
N/A 
2.10.2 
Determination of working voltage 
 
N/A 
2.10.2.1 General 
 
N/A 
2.10.2.2 
RMS working voltage 
 
N/A 
2.10.2.3 
Peak working voltage 
 
N/A 
2.10.3 Clearances 
 
2.10.3.1 General 
 
2.10.3.2 
Mains transient voltages 
 
N/A 
 
a) AC mains supply  ............................................... :  
N/A 
 
b) Earthed d.c. mains supplies  ............................. :  
N/A 
 
c) Unearthed d.c. mains supplies  ......................... :  
N/A 
 
d) Battery operation  .............................................. :  
N/A 
2.10.3.3 
Clearances in primary circuits 
 
N/A 
2.10.3.4 
Clearances in secondary circuits 
Only the functional insulation 
in secondary circuits complied 
with clause 5.3.4 
2.10.3.5 
Clearances in circuits having starting pulses 
 
N/A 
2.10.3.6 
Transients from a.c. mains supply  ........................ :  
N/A 
2.10.3.7 
Transients from d.c. mains supply  ........................ :  
N/A 
2.10.3.8 
Transients from telecommunication networks and 
cable distribution systems  ..................................... :
 N/A 
2.10.3.9 
Measurement of transient voltage levels 
 
— 
 
a) Transients from a mains supply 
 
N/A 
 
For an a.c. mains supply  ....................................... :  
N/A 
 
For a d.c. mains supply  ......................................... :  
N/A 
 
b) Transients from a telecommunication network : 
 
N/A 
2.10.4 Creepage 
distances 
 
N/A 
2.10.4.1 General 
 
N/A 
2.10.4.2 
Material group and comparative tracking index 
 
N/A 
Report No.: SF201300640 
Page 14 of 68
EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
 CTI 
tests 
................................................................. 
:  
⎯ 
2.10.4.3 
Minimum creepage distances 
 
N/A 
2.10.5 Solid 
insulation 
 
N/A 
2.10.5.1 General 
 
N/A 
2.10.5.2 
Distances through insulation 
 
N/A 
2.10.5.3 
Insulating compound as solid insulation 
 
N/A 
2.10.5.4 Semiconductor 
devices 
 
N/A 
2.10.5.5. Cemented 
joints 
 
N/A 
2.10.5.6 
Thin sheet material – General 
 
N/A 
2.10.5.7 
Separable thin sheet material 
 
N/A 
 
Number of layers (pcs) ........................................... :  
— 
2.10.5.8 
Non-separable thin sheet material 
 
N/A 
2.10.5.9 
Thin sheet material – standard test procedure 
 
N/A 
 
Electric strength test 
 
⎯ 
2.10.5.10 
Thin sheet material – alternative test procedure 
 
N/A 
 
Electric strength test 
 
— 
2.10.5.11 
Insulation in wound components 
 
N/A 
2.10.5.12 
Wire in wound components 
 
N/A 
 Working 
voltage  .................................................... :  
N/A 
 
a) Basic insulation not under stress  ...................... :  
N/A 
 
b) Basic, supplementary, reinforced insulation  ..... :  
N/A 
 c) 
Compliance 
with Annex U  ................................. :  
N/A 
 
Two wires in contact inside wound component; 
angle between 45
° and 90°  ................................... :
 
N/A 
2.10.5.13 
Wire with solvent-based enamel in wound 
components 
 
N/A 
 
Electric strength test 
 
-- 
 
Routine test  
 
N/A 
2.10.5.14 
Additional insulation in wound components 
 
N/A 
 Working 
voltage  .................................................... :  
N/A 
 
- Basic insulation not under stress  ........................ :  
N/A 
 
- Supplementary, reinforced insulation  ................. :  
N/A 
2.10.6 
Construction of printed boards 
 
— 
2.10.6.1 
Uncoated printed boards 
 
N/A 
2.10.6.2 
Coated printed boards 
 
N/A 
2.10.6.3 
Insulation between conductors on the same inner 
surface of a printed board 
 N/A 
2.10.6.4 
Insulation between conductors on different layers 
of a printed board 
 N/A 
Report No.: SF201300640 
Page 15 of 68
EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
 
Distance through insulation 
 
N/A 
 
Number of insulation layers (pcs) .......................... :  
N/A 
2.10.7 
Component external terminations 
 
N/A 
2.10.8 
Tests on coated printed boards and coated 
components 
 N/A 
2.10.8.1 
Sample preparation and preliminary inspection 
 
N/A 
2.10.8.2 Thermal 
conditioning 
 
N/A 
2.10.8.3 
Electric strength test 
 
N/A 
2.10.8.4 
Abrasion resistance test 
 
N/A 
2.10.9 Thermal 
cycling 
 
N/A 
2.10.10 
Test for Pollution Degree 1 environment and 
insulating compound 
 N/A 
2.10.11 
Tests for semiconductor devices and cemented 
joints 
 N/A 
2.10.12 
Enclosed and sealed parts 
 
N/A 
 
WIRING, CONNECTIONS AND SUPPLY 
3.1 General 
3.1.1 
Current rating and overcurrent protection 
All internal wires and 
interconnecting cables 
possess adequate cross-
sectional areas for their 
intended application and all 
internal wirings are 
adequately insulated 
3.1.2 
Protection against mechanical damage 
Wires do not touch sharp 
edges and heatsinks which 
could damage the insulation 
and cause hazards 
3.1.3 
Securing of internal wiring 
3.1.4 
Insulation of conductors 
The insulation of the individual 
conductors is suitable for the 
application and the working 
voltage 
3.1.5 
Beads and ceramic insulators 
No beads or similar ceramic 
insulators on conductors. 
N/A 
3.1.6 
Screws for electrical contact pressure 
The equipment does not have 
any screws for electrical 
contact 
N/A 
3.1.7 
Insulating materials in electrical connections 
No contact pressure through 
insulating material. 
Report No.: SF201300640 
Page 16 of 68
EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
3.1.8 
Self-tapping and spaced thread screws 
Thread-cutting or space 
thread screws are not used 
for electrical connections. 
N/A 
3.1.9 
Termination of conductors 
 
 
10 N pull test 
Conducted. 
3.1.10 Sleeving 
on 
wiring 
 
N/A 
 
3.2 
Connection to a mains supply 
N/A 
3.2.1 
Means of connection  
 
N/A 
3.2.1.1 
Connection to an a.c. mains supply 
 
N/A 
3.2.1.2 
Connection to a d.c. mains supply 
 
N/A 
3.2.2 
Multiple supply connections  
 
N/A 
3.2.3 
Permanently connected equipment 
 
N/A 
 
Number of conductors, diameter of cable and 
conduits (mm) ........................................................ :
 
— 
3.2.4 Appliance 
inlets 
 
N/A 
3.2.5 
Power supply cords  
 
N/A 
3.2.5.1 
AC power supply cords 
 
N/A 
 Type 
 
...................................................................... 
:  
— 
 
Rated current (A), cross-sectional area (mm
2
),  
AWG  ...................................................................... :
 
— 
3.2.5.2 
DC power supply cords 
 
N/A 
3.2.6 
Cord anchorages and strain relief 
 
N/A 
 
Mass of equipment (kg), pull (N)   .......................... :  
— 
 Longitudinal 
displacement (mm)  ........................... :  
— 
3.2.7 
Protection against mechanical damage 
 
N/A 
3.2.8 Cord 
guards 
 
N/A 
 
Diameter or minor dimension D (mm); test mass (g) 
 ............................................................................... :
 
— 
 
Radius of curvature of cord (mm)........................... :  
— 
3.2.9 
Supply wiring space 
 
N/A 
 
3.3 
Wiring terminals for connection of external conductors 
N/A 
3.3.1 Wiring 
terminals 
 
N/A 
3.3.2 
Connection of non-detachable power supply cords
 
N/A 
3.3.3 Screw 
terminals 
 
N/A 
3.3.4 
Conductor sizes to be connected 
 
N/A 
 
Rated current (A), cord/cable type, cross-sectional 
area (mm
2
) ............................................................. :
 
⎯ 
3.3.5 
Wiring terminal sizes 
 
N/A 