US National Difference according to CB Bulletin No. 109A, December 2005
12.1.4
Add to the end of the 1st paragraph: “As an alternative, any
number form one to three samples are permitted to be used
in any combination that results in a total of three drops.”
number form one to three samples are permitted to be used
in any combination that results in a total of three drops.”
Considered
P
12.1.6
Add: Handle strength test requirements.
No handle provided.
N/A
12.7
Add: Wall and ceiling mounting means test requirements.
No such equipment provided.
N/A
12.8
Add test for enclosures, barriers, components and leads
that rely on adhesive.
that rely on adhesive.
No such adhesive provided.
N/A
12.8.1
Add test for conductive labels secured in place by adhesive.
N/A
13
Add: “Component power supplies and their power
transformers complying with the construction and test
requirements of UL 1310, UL1950 Third Edition, or UL
60950 are considered to fulfill the test requirements on the
clause.”
transformers complying with the construction and test
requirements of UL 1310, UL1950 Third Edition, or UL
60950 are considered to fulfill the test requirements on the
clause.”
N/A
13.4
Modification: A material group is verified according to UL
746A.
746A.
(see appended table 14)
P
13.5.1
Change standard reference from IEC 60249-2 to UL 796.
No coated PCB provided.
N/A
13.5.2
Modification: Coated printed wiring boards shall comply with
requirements in UL 746C Table 12 – note 3 revised to refer
to UL 746A.
requirements in UL 746C Table 12 – note 3 revised to refer
to UL 746A.
N/A
14
Delete Note 2. Add reference to Annex Y and additional
component requirements.
component requirements.
14.1, 14.2 and 14.3 – Add: “Component power supplies and
their resistors complying with the construction and test
requirements of Clause 14.1 and 14.2.1 – 14.5.2..14.2.1
and 14.2.2 – Add: “As an alternative a component such as
capacitor, a combination capacitor and resistor, a varistor,
or a suppressor shall comply with the requirements for
Across-the Line, Antenna-Coupling, or Double Protection in
UL 1414.”
their resistors complying with the construction and test
requirements of Clause 14.1 and 14.2.1 – 14.5.2..14.2.1
and 14.2.2 – Add: “As an alternative a component such as
capacitor, a combination capacitor and resistor, a varistor,
or a suppressor shall comply with the requirements for
Across-the Line, Antenna-Coupling, or Double Protection in
UL 1414.”
Added
P
14.2.4
Replace text with: “Components subjected to the
requirements in 14.2.1 and 14.2.2 shall also comply with the
enclosure requirements of UL 1414.”
requirements in 14.2.1 and 14.2.2 shall also comply with the
enclosure requirements of UL 1414.”
(see appended table 14)
P
14.4
Add to Note 2: “High voltage materials shall be rated 94V-2
minimum.”
minimum.”
Not such transformer
N/A
14.4.1
Replace with High voltage arcing test.
N/A
14.4.2
Deleted.
N/A
14.4.3
Add: High voltage component part flame test.
N/A
<12014165 001>
Page 57 of 73
National Deviation
Clause
Requirement – Test
Result - Remark
Verdict
US National Difference according to CB Bulletin No. 109A, December 2005
14.4.4
Add: High voltage isolation component insulation test.
N/A
14.5.1
Delete reference to 14.5.1.3.
N/A
14.5.1.1
Replace text with: Thermal cutouts shall comply with UL
873, UL 8730-2-9 or UL 60730-2-9.
873, UL 8730-2-9 or UL 60730-2-9.
No thermal cutouts provided.
N/A
14.5.1.2
Replace text with: “Thermal links shall comply with UL 1020
or IEC 60691.”
or IEC 60691.”
No thermal link provided.
N/A
14.5.1.3
Delete.
N/A
14.5.2.1
Modification: Fuse links shall comply with UL 248-14.
Added.
P
14.5.2.2
Delete reference to IEC 60127 and breaking capacity marking
requirements.
requirements.
Delete.
P
14.5.3
Add: As an option, a PTC thermistor may comply with UL
1434. Delete the 3rd and 4th paragraphs.
1434. Delete the 3rd and 4th paragraphs.
No PTC provided.
N/A
14.5.3A
Add: Protective devices connected to the mains shall have
adequate breaking capacity and comply with UL 873,
UL1416, UL 1417 or UL 2111 as applicable.
adequate breaking capacity and comply with UL 873,
UL1416, UL 1417 or UL 2111 as applicable.
No such component
provided.
provided.
N/A
14.5.4
Reference to fuse-links is deleted.
Delete.
P
14.6.1
Add: “Switches and relays shall comply with UL 1054, UL
61058-1 or UL 508 as applicable. Mains switch or relay shall
be rated for the total current through the switch or relay
contacts.”
61058-1 or UL 508 as applicable. Mains switch or relay shall
be rated for the total current through the switch or relay
contacts.”
Replace remaining text with: “A rating of a mains switch or
relay, provided on a audio apparatus intended for commercial
use, is to be equal to or greater than the maximum steady
state current it controls under normal operating conditions
except the audio output is adjusted to 1/3 maximum
undistorted output or at 1/3 of the 14.6.2, 14.6.3 and 14.6.4
are deleted.
relay, provided on a audio apparatus intended for commercial
use, is to be equal to or greater than the maximum steady
state current it controls under normal operating conditions
except the audio output is adjusted to 1/3 maximum
undistorted output or at 1/3 of the 14.6.2, 14.6.3 and 14.6.4
are deleted.
No switch provided.
N/A
14.6.5
Modification: A switch or relay that controls a mains socket-
outlet shall have a rating equal to the rated current
consumption of the apparatus plus the current rating of the
socket-outlet.
outlet shall have a rating equal to the rated current
consumption of the apparatus plus the current rating of the
socket-outlet.
N/A
14.6.6
Add: A mains switch shall comply with (a), (b) or (c). The
contacts of a mains relay shall comply with (a), (b) or (d). A
switch that controls a mains receptacle shall comply with (b)
and a relay that controls a mains receptacle shall comply with
(b) or (d).
contacts of a mains relay shall comply with (a), (b) or (d). A
switch that controls a mains receptacle shall comply with (b)
and a relay that controls a mains receptacle shall comply with
(b) or (d).
N/A
<12014165 001>
Page 58 of 73
National Deviation
Clause
Requirement – Test
Result - Remark
Verdict
US National Difference according to CB Bulletin No. 109A, December 2005
14.6.6a
Add: Switch or relay contacts to have current rating equal to
or greater than 1.414 times the inrush current of the
apparatus.
or greater than 1.414 times the inrush current of the
apparatus.
N/A
14.6.6b
Add: Switch or relay to be TV rated.
N/A
14.6.6c
Add: Switch is located on the back of apparatus and is not
operable from a remote control.
operable from a remote control.
N/A
14.6.6d
Add: Relay is to be subjected to the endurance test.
N/A
14.6.6.1
Add: Peak inrush current test.
N/A
14.6.6.2
Add: Realy endurance test.
N/A
14.6.7
Add: Double pole switch controlling a.c. and d.c. circuits shall
be suitable for the application.
be suitable for the application.
N/A
14.7
Add to the end of the 2nd paragraph“...except that the jointed
test finger to in 9.1.1 is used to determine accessibility (IEC
60950, 2.8.2) and interlock operation (IEC 60950, 2.8.3).”
test finger to in 9.1.1 is used to determine accessibility (IEC
60950, 2.8.2) and interlock operation (IEC 60950, 2.8.3).”
No safety interlock provided.
N/A
14.10.6
Add: “An apparatus intended for use with an external battery
shall be provided with an overcurrent protective device in the
battery-supply circuit.”
shall be provided with an overcurrent protective device in the
battery-supply circuit.”
No battery provided.
N/A
14.11
Add: “Component power supplies and their optocouplers
complying with the construction and test requirements of UL
1310, UL 1950 Third Edition, or UL 60950 are considered to
fulfill the test requirements on the clause.”
complying with the construction and test requirements of UL
1310, UL 1950 Third Edition, or UL 60950 are considered to
fulfill the test requirements on the clause.”
Optocouplers bridging reinforced insulation shall comply with
requirements for double protection as specified in UL 1577.
requirements for double protection as specified in UL 1577.
4th paragraph reads: “External clearances and creepage
distances of optocouplers shall comply with 13.1.”
distances of optocouplers shall comply with 13.1.”
Added
P
14.12
Replace “IEC 61051-2” with “UL 1449” and “UL 94.” Delete all
references to “IEC 60151”
references to “IEC 60151”
UL approved varistor used
P
15.1.1
Add: “Attachment plug shall have a current rating no less than
125% of the current drawn under normal operating conditions
and a voltage rating appropriate for the rated voltage of the
apparatus. Attachment plugs for use on more than one supply
voltage by means of a voltage selector shall be rated for the
voltage, which the apparatus is intended to be connected
when it is shipped from the factory. Attachment plug cap shall
be polarized when the apparatus is provided with a manually
operated, line connected, single-pole switch; Edison-base
lampholder; or a 15 or 20A socket outlet.”
125% of the current drawn under normal operating conditions
and a voltage rating appropriate for the rated voltage of the
apparatus. Attachment plugs for use on more than one supply
voltage by means of a voltage selector shall be rated for the
voltage, which the apparatus is intended to be connected
when it is shipped from the factory. Attachment plug cap shall
be polarized when the apparatus is provided with a manually
operated, line connected, single-pole switch; Edison-base
lampholder; or a 15 or 20A socket outlet.”
Direct plug-in appliance.
Tested with appliance.
Tested with appliance.
N/A
15.1.2
Delete reference to “Banana” plug in the Note.
Deleted
P
<12014165 001>
Page 59 of 73
National Deviation
Clause
Requirement – Test
Result - Remark
Verdict
US National Difference according to CB Bulletin No. 109A, December 2005
15.1.3.1
Add: “An audio amplifier having an open-circuit audio output
voltage not limited to 120V that is permanently connected to
the mains shall be provided with a means for connection
complying with U.21.1.1-U.21.1.7 and wire-binding screws
No. 6-32 or larger complying with U.21.3.1-U.21.3.5, or quick-
connect terminals, or leads. Quick Connect Terminal shall
comply with the following: a) Male tabs firmly mounted in
place, b) Mating female connectors shall be provided with the
apparatus, c) Strain Relief Test of Clause 16.5, d) Installation
instructions shall be provided for assembly of terminal to a
conductor and strain relief, e) Terminals shall be appropriate
for use with the size and type of wire specified.”
voltage not limited to 120V that is permanently connected to
the mains shall be provided with a means for connection
complying with U.21.1.1-U.21.1.7 and wire-binding screws
No. 6-32 or larger complying with U.21.3.1-U.21.3.5, or quick-
connect terminals, or leads. Quick Connect Terminal shall
comply with the following: a) Male tabs firmly mounted in
place, b) Mating female connectors shall be provided with the
apparatus, c) Strain Relief Test of Clause 16.5, d) Installation
instructions shall be provided for assembly of terminal to a
conductor and strain relief, e) Terminals shall be appropriate
for use with the size and type of wire specified.”
Not audio amplifier
N/A
15.1.3.2
Add: “Audio amplifiers having an audio output not limited to
120V that are connected to the mains by a flexible cord shall
have suitable cord or provision for field installation or a
receptacle for plug-in connections,”
120V that are connected to the mains by a flexible cord shall
have suitable cord or provision for field installation or a
receptacle for plug-in connections,”
Not audio amplifier
N/A
15.2
Add after 3rd paragraph: “The earthing conductor in a supply
cord, or in an interconnecting cable shall have an equivalent
or large cross-sectional area that the current-carrying
conductors in the supply cord or cable. With reference to
earthing conductors, the insulation color may be green or
green/yellow.
cord, or in an interconnecting cable shall have an equivalent
or large cross-sectional area that the current-carrying
conductors in the supply cord or cable. With reference to
earthing conductors, the insulation color may be green or
green/yellow.
Class II equipment.
N/A
15.3.5
Revise 2nd paragraph to read: “For rated currents exceeding
13A, reference is made to Article 310 of the National
Electrical Code, ANSI/NFPA 70.” Table 15 – Replace with:
“Normal cross-sectional area AWG” and modify values.
13A, reference is made to Article 310 of the National
Electrical Code, ANSI/NFPA 70.” Table 15 – Replace with:
“Normal cross-sectional area AWG” and modify values.
Direct plug-in appliance.
N/A
15.4
Add: “Component power supply adaptors complying with the
construction and test requirements on the clause.”
construction and test requirements on the clause.”
See attached plug partial test
report.
report.
P
16.1
Modification: Mains supply flexible cords shall comply with UL
817, be marked VW-1, and have an ampacity not less than
the current drawn by the apparatus. Delete reference to IEC
60227, 60245 and 60173.
817, be marked VW-1, and have an ampacity not less than
the current drawn by the apparatus. Delete reference to IEC
60227, 60245 and 60173.
Table 17A – Add: Types of cords and lengths for various
types of apparatus.
types of apparatus.
Direct plug-in appliance.
N/A
16.2
An integral earthing conductor shall be at least the same size
as the other cord conductors. Substitute “IEC 60950, table
3B” with“ Article 400 of the National Electrical Code”.
as the other cord conductors. Substitute “IEC 60950, table
3B” with“ Article 400 of the National Electrical Code”.
Table 18 – Replace with “Wire sizes of external flexible cords”
Upper current limit in column 1 increased from 16 to 30A and
“AWG” wire sizes added.
Upper current limit in column 1 increased from 16 to 30A and
“AWG” wire sizes added.
N/A