JBL ON TIME 200ID EMC - CB Certificate ▷ View online
<12014165 001>
Page 72 of 73
UL 1310 (Partial)
Clause
Requirement – Test
Result - Remark
Verdict
The integrated part of plug was tested according to UL1310 (partial):
** weight and Moment Determination: (direct plug in unit)
** weight and Moment Determination: (direct plug in unit)
W
S
X
Y
Z
WY/Z
WY/S
WX
180
23,8
0,5
17,2
16,6
186,5
130,1
90,0
Result: W did not exceed 794 grams, WY/Z did not exceed 1361 grams, WY/S did not exceed 1361 grams, and
WX did not exceed 0,56Nm (57606 gram-millimeters).
** Rod pressure test: (direct plug-in unit)
each sample was connected to the source of supply. A force increasing from 0-20 lb over a period of 5s was
applied through the axis of the rod perpendicular to the surface of the enclosure as indicated below. The rod was ½
in. Diameter, had a flat face, with edges rounded to a radius of 1/32 in. Each test was continued for 1 min.
after rod pressure test, the openings didnot develop in the enclosure that exposed live circuit part. The
enclosure to earth Ground measurements are not applied; passed.
** Dielectric voltage withstand test (after Rod pressure test):
one min following the preceding rod pressure test, the following potentials were gradually applied and maintained
for one min.
** Dielectric voltage withstand test (after Rod pressure test):
one min following the preceding rod pressure test, the following potentials were gradually applied and maintained
for one min.
3000VAC between primary circuits and exposed conductive surfaces, 3000VAC between primary and
secondary circuits, 4242VDC between primary circuit and secondary circuits.
Result: the spacings and insulation withstood the application of the specified potentials for one min without
indication of breakdown; passed
** resistance to crushing test: (direct plug-in unit)
each sample was placed between two maple blocks. Each block was not less than ½ in. Thick, and one block had
slots for the plug blades. A crushing force of 75 lb was applied gradually in a direction normal to the mounting
surface for a period of 1 min.
** resistance to crushing test: (direct plug-in unit)
each sample was placed between two maple blocks. Each block was not less than ½ in. Thick, and one block had
slots for the plug blades. A crushing force of 75 lb was applied gradually in a direction normal to the mounting
surface for a period of 1 min.
Result: there was no shattering, cracking , or other damage to the enclosure that would expose internal wiring or
live parts; passed.
** blade secureness test: (direct plug-in unit)
each unit was supported on a horizontal steel plate with the blades (and grounding pin, if provided), projecting
downward through a hole having a diameter sufficient only to permit the blades to pass through.
** blade secureness test: (direct plug-in unit)
each unit was supported on a horizontal steel plate with the blades (and grounding pin, if provided), projecting
downward through a hole having a diameter sufficient only to permit the blades to pass through.
<12014165 001>
Page 73 of 73
UL 1310 (Partial)
Clause
Requirement – Test
Result - Remark
Verdict
A 20 lb weight was supported by each blade (and grounding pin) in succession, and then by the two blades tested
together. Each test was two min in length.
Result: the blades did not loosen or pull out; passed
** input contact security test: (direct plug-in)
together. Each test was two min in length.
Result: the blades did not loosen or pull out; passed
** input contact security test: (direct plug-in)
each sample was rigidly supported in the blades up position. Each blade (and the grounding pin, if provided) in
succession was subjected to a force of 30 lb applied gradually in a direction towards the face of the sample. The
same sample was retested subjecting both blades ( and the grounding pin) to a single applied force of 40 lb. Each
test was one min in length.
same sample was retested subjecting both blades ( and the grounding pin) to a single applied force of 40 lb. Each
test was one min in length.
Result: the blades did not loosen to a degree that would introduce a risk of fire or electric shock; passed.
Report Number:
12014165 001
Model:
S024Ezxy
Page 1 of 17
Picture 1
Picture 2
Report Number:
12014165 001
Model:
S024Ezxy
Page 2 of 17
Picture 3
Picture 4