JBL ON TIME 200ID EMC - CB Certificate ▷ View online
Report Number:
12014165 001
Model:
S024Ezxy
Page 3 of 17
Picture 5
Picture 6
The live parts could not be touched by
plastic barrier. Plastic barrier is
moulded with plug portion together.
plastic barrier. Plastic barrier is
moulded with plug portion together.
Report Number:
12014165 001
Model:
S024Ezxy
Page 4 of 17
Picture 7
Picture 8
Metal plug pin
was mounted
by screw.
was mounted
by screw.
Cr. and Cl
between live
parts and
accessible
parts: 7.0mm
between live
parts and
accessible
parts: 7.0mm
Report Number:
12014165 001
Model:
S024Ezxy
Page 5 of 17
Picture 9
Picture 10
Metal plug pin was
mounted in plug
portion.
mounted in plug
portion.
Cr and Cl between
live parts to
accessible parts:
6.0mm
live parts to
accessible parts:
6.0mm
Cr and Cl between live parts
to accessible parts: 7.0mm
to accessible parts: 7.0mm
Metal plug pin was
mounted in plug
portion.
mounted in plug
portion.
Report Number:
12014165 001
Model:
S024Ezxy
Page 6 of 17
Picture 11
Picture 12
Click on the first or last page to see other ON TIME 200ID service manuals if exist.