JBL ON TIME 200ID EMC - CB Certificate ▷ View online

 
 
<12014165 001> 
 
 
Page 52 of 73 
 
National Deviation 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
US National Difference according to CB Bulletin No. 109A, December 2005 
 
APPENDIX  US National Differences according to CB Bulletin No. 109A, December 2005 (UL 60065) 
(IEC Publication 60065 7th edition, 2001) 
EXPLANATION FOR ABBREVIATIONS 
P=Pass, F=Fail, N=Not applicable.  Placed in the column to the right. 
1.1.1 
Scope clarification: 
The standard also covers commercial and professional 
apparatus; professional apparatus may also be investigated 
using UL 1419. Projection apparatus is not covered. 
Household games, household gaming and scoring machines, 
satellite receiver antenna positioners are covered by this 
standard but commercial games and commercial gaming and 
scoring machines, and other types of antenna positioners are 
covered by other standard. 
Add: Mains connected apparatus intended for field installation 
requires compliance with the National Electrical Code, ANSI, 
NFPA 70. 
Considered. 
1.1.3 
Protection against splashing water replaced with apparatus 
intended for outdoor use (See Annex A). 
 
N/A 
1.1.5 
Add: Some equipment covered by these requirements may 
also be required to comply with applicable requirements in 
other standards 
Added 
1.2 
Add references to ANSI, ASTM and UL standards. 
Added 
4.2.1 
Add Note: In the U.S. the RATED SUPPLY VOLTAGE for 
single-phase apparatus is assumed to be 120 V or 120/240 V. 
Input voltage is 100-240Vac 
4.2.4  
Revision to sub-clause a): Minimum audio output is not less 
than 0.5 W per channel unless the maximum audio output is 
less than 0.5 W per channel.   
No audio output provided. 
N/A 
4.2.4.1 
Add: “An apparatus with multiple modes of operation, multiple 
signal input sources, or both, is to be operated using each 
mode of operation or signal input source separately, or in 
combination, according to the manufacturer’s instructions to 
produce the maximum power input”. 
Table 2: External supply sources are assumed to be capable 
of delivering 30 A, unless otherwise specified (no-load voltage 
and internal resistance values in the Table are modified). 
Not such equipment 
N/A 
4.3.4 
PTC thermistors may also comply with UL 1434. 
No PTC provided. 
N/A 
 
 
<12014165 001> 
 
 
Page 53 of 73 
 
National Deviation 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
US National Difference according to CB Bulletin No. 109A, December 2005 
 
5.1 
Add: Component power supplies and adapters complying with 
the construction and test requirements of UL 1310, UL 1950, 
or UL 60950 fulfill the requirements of items “a” through “i” of 
this clause. 
Added 
N/A 
5.1f 
Add: Rated frequency is required on all apparatus. 
50/60Hz 
5.1g 
Add: Rated current or power required on all apparatus. 
1,5A 
5.1j 
Add: Date of Manufacture marking required on all apparatus.  Date of manufacture show on 
outer enclosure. 
5.1k 
Add: Manufacturing identification marking required. 
Only one factory. 
N/A 
5.1l 
Add: Combination of two graphical symbols and 
supplementary marking is required. 
The enclosure of EUT is 
sealed by ultrasonic welding, 
No possibility for user to open 
by tools. 
N/A 
5.1m 
Add: Equipment rack marking required for audio/video 
systems. 
No rack provided. 
N/A 
5.1n 
Add: Units having leakage current levels greater than 0.75 
MIU and equal to or less than 3.5 MIU must be marked with a 
high leakage current marking. 
Leakage current no less than 
0.75MIU, for details refer to 
clause 9.1. 
N/A 
5.2c 
Modification: Output terminals must be marked with voltage, 
frequency and current or power; output terminals installed or 
interconnected in the field must be marked with the class of 
wiring.  
The nominal output voltage 
and current are marked on 
the name label. 
5.2d 
Add: Audio output connections shall be marked “Class 1 
Wiring”, “Class 2 Wiring” or “Class 3 Wiring”. Operation 
manual shall discuss risks and proper connecting and 
insulation techniques when connecting a speaker. 
No audio output connections 
provided. 
N/A 
5.3 
Add: “An explanation and illustration of safety related 
graphical symbols used on the apparatus shall be included in 
the owner’s instructions preceding any operating instructions. 
No such symbols. 
N/A 
5.4 
Add: Important Safety Instructions are to be packed with each 
apparatus and shall be verbatim. 
 
5.4.1 
Warning about Outdoor Use is required. 
Indoor use logo was added in 
the label and warning added 
in the user manual 
5.4.3 
Add: When apparatus contains instructions for use by service 
personnel the instructions are separate in format and 
preceded by a precautionary warning statement. 
Not use by service personnel 
N/A 
 
 
<12014165 001> 
 
 
Page 54 of 73 
 
National Deviation 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
US National Difference according to CB Bulletin No. 109A, December 2005 
 
6.1 
Starting from second paragraph replace all by: ”Compliance is 
checked in accordance with the requirements in the U.S. 
Code of Federal Regulation, Title 21, Chapter 1, Subchapter 
J, Sections 1010.2, 1010.3 and 1020.10 by measuring the 
radiation produced by the apparatus employing a design 
center chassis.”  
No radiation 
N/A 
6.2 
Starting from second paragraph replace all by: “Apparatus 
shall be classified and labeled in accordance with the Code of 
Federal Regulations, Title 21, Chapter 1, Subchapter J, 
Sections 1010.2, 1010.3, 1040.10 and 1040.11.” 
No ionizing radiation or laser 
inside the equipment. 
N/A 
6.2.2 
Deleted 
Table 3: Temperature limits added for various classes of 
insulation systems. 
Add to Note a): “Materials rated in accordance with UL 746B 
may be used at their rated higher temperature.”.7.2 – Add: A 
material temperature rating can be accepted in lieu of the 
softening temperature. The softening test need not be 
performed on materials used in UL Listed or Recognized 
parts. 
Deleted and added. 
N/A 
8.1 
Add: “A metal part that is not inherently resistant to corrosion 
shall be protected against corrosion when corrosion of that 
part is capable of contributing to or resulting in a risk of fire, 
shock, or injury to persons.” 
Added. 
8.9.1 
Add: “Sleeving, tape, tubing, and wire insulation are suitable 
for the conditions of use, such as voltage and temperature, 
and comply with UL 224, UL 510, and UL 1441, as 
applicable.”  
UL approved material used 
8.10 
Add: “Component power supplies and their internal insulation 
complying with the construction and test requirements of UL 
1310, UL 1950 Third Edition, or UL 60950 are considered to 
fulfill the test requirements on the clause.”  
Considered. 
N/A 
8.12 
Modification: Conductors and internal wiring connecting mains 
socket-outlets shall comply with the wire size requirements in 
clause 16.2 based on the marked rating of the outlet but shall 
not be less than 18 AWG. 
No socket-outlet 
N/A 
8.17 
As an option, winding wire insulation may comply with the 
requirements in UL Subject 2353. 
Added. 
8.19.1 
Modification: An all-pole switch or circuit breaker is not 
required to have contact separation of 3 mm.  
No switches provided. 
N/A 
 
 
<12014165 001> 
 
 
Page 55 of 73 
 
National Deviation 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
US National Difference according to CB Bulletin No. 109A, December 2005 
 
8.22 
Add: “Printed wiring boards involved with the risk of electric 
shock shall comply with the requirements in UL 796.” 
UL approved PCB is used. 
9.1.1.1 
Replace: For Class I apparatus the r.m.s. TOUCH-CURRENT 
to earth shall not be more than 3.5 MIU.  
Class II equipment. 
N/A 
9.1.1.1a 
2nd dash replaced by: “For audio signals of professional and 
commercial apparatus, 120 Vrms.”  
3rd dash replaced by: ”For audio signals other than 
professional and commercial apparatus, 71 Vrms.” 
No such signal. 
N/A 
9.1.1.1b 
Modification: Touch current shall comply with the American 
National Standard for Leakage Current for Appliances, ANSI 
C101 and not exceed 0.5MIU for Class II Delete Note 2. 
L/N to Enclosure: 0,17MIU; 
L/N to output terminal: 
0,08MIU 
9.1.1.2 
UL articulated finger replaces IEC 61032 test probe B. Delete 
3rd paragraph. 
Table 5 – Add Note 1: “With respect to mains voltages in the 
range of 105-130 V(rms), the test voltages are considered to 
be 1414 V peak for basic and supplementary insulation and 
2828 V peak for reinforced insulation.”  
Considered 
11 
Add: “Component power supplies and their power 
transformers complying with the construction and test 
requirements of UL 1310, UL 1950 Third Edition, or UL 60950 
are considered to fulfill the test requirements on the clause.”  
 
N/A 
11.1 
Modification: The permissible touch current for terminal 
contacts has been increased to twice the value given in 
9.1.1.1. 
L/N to Enclosure: 0,17MIU; 
L/N to output terminal: 
0,08MIU 
11.2.1 
Modification: Additional fuse testing not required if the 
temperature is limited by fuses. 
Considered 
12 
Add: “Component power supply adaptors and their 
enclosures complying with the construction and test 
requirements of UL 1310, UL 1950 Third Edition, or UL 
60950 are considered to fulfill the test requirements on the 
clause.”  
 
N/A 
12.1.3 
Delete the first tow paragraphs. Impact test uses the 50mm 
steel sphere only. 
Table 6 – Replace title with “Apparatus impact test.” Table 6 
modified to provide impact test criteria detailing impact 
location, impact energy and additional pass/fail results.” 
Considered 