JBL ON TIME 200ID EMC - CB Certificate ▷ View online
<12014165 001>
Page 36 of 73
IEC60065E
ASTABEAB
Object/Part No.
Manufacturer
/Trademark
/Trademark
Type/Model
Technical Data
2
)
Standard
Mark(s) of
Conformity
Conformity
1
)
Line filter (L1)
(output power ≤
15W)
(output power ≤
15W)
Huizhou Sky
Fortune
Fortune
S3316A
Pin1-2, Pin3-4:
Ø0,22mm×125Ts,
15,0mH min, 130°C
Ø0,22mm×125Ts,
15,0mH min, 130°C
--
--
Line filter (L1)
(15W < output
power ≤ 24W)
(15W < output
power ≤ 24W)
Huizhou Sky
Fortune
Fortune
S3399A
Pin1-2, Pin3-4:
Ø0,30mm×70Ts,
5,8mH min, 130°C
Ø0,30mm×70Ts,
5,8mH min, 130°C
--
--
Fuse (F1)
Ever Island
2010
T3,15AL AC250V,
sub-miniature fuse link
sub-miniature fuse link
IEC/EN 60127-3 VDE
UL E220181
(Alternative)
Wickmann-Werke 392
T3,15AL AC250V,
sub-miniature fuse link
sub-miniature fuse link
IEC/EN 60127-3 VDE
UL E67006
Fusing resistor
(F1)
(F1)
TY-OHM
FKN
2.2Ω/1W
--
Tested with
appliance
appliance
(Alternative)
HMR
JRW-FU1W
2.2Ω/1W
--
Tested with
appliance
appliance
Opto-coupler
(IC2)
(IC2)
Sharp
PC817
Int./ext.Cr.= 6,4/8,0mm,
Dti=0,45mm
Dti=0,45mm
IEC/EN 60950
VDE 0884
VDE 0884
VDE
UL E64380
UL E64380
(Alternative)
Lite-On
LTV-817
Int./ext.Cr.= 5,2/7,8mm,
Dti=0,8mm
Dti=0,8mm
IEC/EN 60950
VDE 0884
VDE 0884
VDE
UL E113898
UL E113898
(Alternative)
Bright Led
BPC 817
Int./ext.Cr.= 5,0/7,8mm,
Dti>0,4mm
Dti>0,4mm
IEC/EN 60950
VDE 0884
VDE 0884
VDE
UL E236324
UL E236324
(Alternative)
Kodenshi
PC-17K1
Int./ext.Cr.> 4,0/8,0mm,
Dti>0,4mm
Dti>0,4mm
IEC/EN 60950
VDE 0884
VDE 0884
VDE
UL E107486
UL E107486
Varistor (MOV)
(optional)
(optional)
Success
SVR-7D471K
AC300V, DC385V
IEC 61051
CECC 42200
CECC 42200
VDE
UL E114280
UL E114280
(Alternative)
Song Long
SAS-471KD07
AC300V, DC385V
IEC 61051
CECC 42200
CECC 42200
VDE
UL E171541
UL E171541
(Alternative)
Centra
CNR-07D471K AC300V, DC385V
IEC 61051
CECC 42200
CECC 42200
VDE
UL E150709
UL E150709
NTC
Thinking
SCK-053M
5Ω, 3A at 25°C
--
UL E138827
(Alternative)
Joyin
8S050M
5Ω, 3A at 25°C
--
UL E171531
Y1 capacitor
(CY1)
(CY1)
Jya-Nay
JN
AC250V, 2200pF,
25/125/21/A, Y1 type
25/125/21/A, Y1 type
IEC 60384-14
VDE
UL E201384
UL E201384
(Alternative)
Success
SE
AC250V, 2200pF,
30/125/56/C, Y1 type
30/125/56/C, Y1 type
IEC 60384-14
VDE
UL E114280
UL E114280
(Alternative)
Pan Overseas
AH
AC400V, 2200pF,
25/125/21/C, Y1 type
25/125/21/C, Y1 type
IEC 60384-14
VDE
UL E146544
UL E146544
X2 capacitor
(CX1)
(CX1)
Tenta
MEX
AC275V, max. 0,33µF,
40/100/21/C, X2 type
40/100/21/C, X2 type
IEC 60384-14
VDE
UL E186475
UL E186475
<12014165 001>
Page 37 of 73
IEC60065E
ASTABEAB
Object/Part No.
Manufacturer
/Trademark
/Trademark
Type/Model
Technical Data
2
)
Standard
Mark(s) of
Conformity
Conformity
1
)
(Alternative)
Ultra Tech
HQX
AC275V, max. 0,33µF,
40/100/56/C, X2 type
40/100/56/C, X2 type
IEC 60384-14
VDE
UL E183780
UL E183780
(Alternative)
Shengxin
MEX
AC275V, max. 0,33µF,
40/100/21/B, X2 type
40/100/21/B, X2 type
IEC 60384-14
VDE
UL E207221
UL E207221
(Alternative)
Strong
MPX
AC275V, max. 0,33µF,
40/100/21/B, X2 type
40/100/21/B, X2 type
IEC 60384-14
VDE
UL E230903
UL E230903
Enclosure
Guangzhou
Kingfa
Kingfa
JH830
PC, V-0, 80°C, min.
thickness: 2,1mm
thickness: 2,1mm
--
UL E171666
(Alternative)
Chi Mei
PA-765(+)
ABS, V-0, 80°C, min.
thickness: 2,1mm
thickness: 2,1mm
--
UL E56070
(Alternative)
Kumho
HFA-700HT
ABS, V-0, 85°C, min.
thickness: 2,1mm
thickness: 2,1mm
--
UL E65424
PCB
Various
Various
Min.V-0, 130°C, min.
thickness: 1,5mm
thickness: 1,5mm
--
UL
Heat shrinkable
tube
tube
Chang Yuan
Changbao 102
125°C, 600V, VW-1
--
UL E180908
(Alternative)
Sumitomo
Sumitube F2
125°C, 600V, VW-1
--
UL E48762
Output cord
(except for US
and CA)
(except for US
and CA)
Various
Various
PVC
--
--
Output cord
Various
Various
80°C, 300V, VW-1,
PVC
PVC
--
UL
Electrolytic
capacitor (C1)
capacitor (C1)
Various
Various
AC400V, 22-47µF,
105°C
105°C
--
--
Rectifying diode
bridging (BR1)
bridging (BR1)
Various
Various
Min. AC600V, 2A
--
--
MOSFET (Q1)
Various
Various
Min. AC600V, 2A
--
--
Bleeding resistors
(R1, R2)
(R1, R2)
Various
Various
AC200V, 1MΩ
--
--
Pin sleeving (for
Euro-plug)
Euro-plug)
Nan Ya
6410G5
PA66, V-0, 130°C
--
UL E130155
(Alternative)
GE
SE1(f1)
PPE+PS, V-1, 110°C,
--
UL E121562
Pin holder
Samyang
3025N1,
3025PN1
3025PN1
PC, V-0, 80°C
--
UL E121254
(Alternative)
Guangzhou
Kingfa
Kingfa
JH830
PC, V-0, 80°C
--
UL E171666
(Alternative)
GE
940(f1)
PC, V-0, 130°C
--
UL E121562
<12014165 001>
Page 38 of 73
IEC60065E
ASTABEAB
Object/Part No.
Manufacturer
/Trademark
/Trademark
Type/Model
Technical Data
2
)
Standard
Mark(s) of
Conformity
Conformity
1
)
Euro-plug
Ten Pao
83-V
AC250V, 0,6A
EN 50075
Tested with
appliance
appliance
UK plug
Ten Pao
83-B
AC250V, 0,6A
BS 1363
Tested with
appliance
appliance
American plug
Ten Pao
83-UC
AC125V
UL 1310
Tested with
appliance
appliance
1
) An asterisk indicates a mark which assures the agreed level of surveillance.
2
) Description to include adjacent markings for critical fuse/s.
<12014165 001>
Page 39 of 73
National Deviation
Clause
Requirement – Test
Result - Remark
Verdict
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
P
2.6.1
DK: certain types of Class I apparatus, see 15.1.1, may be
provided with a plug not establishing earthing continuity when
inserted in Danish socket-outlets
provided with a plug not establishing earthing continuity when
inserted in Danish socket-outlets
Class II appliance.
N/A
13.3.1
NO: In Norway, due to IT power distribution system used, the
a.c. MAINS supply voltage is considered to be equal to the
line-to-line voltage, and will remain 230V in case of a single
earth fault.
a.c. MAINS supply voltage is considered to be equal to the
line-to-line voltage, and will remain 230V in case of a single
earth fault.
Considered.
P
15.1.1
DK: mains cord for single-phase equipment having a rated
current not exceeding 10 A shall be provided with a plug
according to Heavy Current Regulations Section 107-2-D1
current not exceeding 10 A shall be provided with a plug
according to Heavy Current Regulations Section 107-2-D1
Direct plug-in appliance.
N/A
DK: Class I equipment with socket-outlets with earthing
contact, or which are intended to be used in locations where
protection against indirect contact is required shall be
provided with a plug in compliance with Standard Sheet
DK 2-1a
contact, or which are intended to be used in locations where
protection against indirect contact is required shall be
provided with a plug in compliance with Standard Sheet
DK 2-1a
No socket-outlets provided.
N/A
DK: socket-outlets for providing power to Class II equipment
with a rated current of 2,5 A shall have dimensions according
to the drawing on page 131 of EN 60 065:98 other
dimensions shall be to IEC 60 083 Standard Sheet C 1a for
portable socket-outlets
with a rated current of 2,5 A shall have dimensions according
to the drawing on page 131 of EN 60 065:98 other
dimensions shall be to IEC 60 083 Standard Sheet C 1a for
portable socket-outlets
No socket-outlets provided.
N/A
DK: mains socket-outlets with earthing contact shall comply
with Heavy Current Regulations Section 107-2-D1, Standard
Sheet DK 1-3a, DK 1-5a or DK 1-7a
with Heavy Current Regulations Section 107-2-D1, Standard
Sheet DK 1-3a, DK 1-5a or DK 1-7a
No socket-outlets provided.
N/A
GB: equipment fitted with a flexible cable or cord provided
with a 13A BS 1363 plug as in Statutory Instrument 1768:94
with a 13A BS 1363 plug as in Statutory Instrument 1768:94
Direct plug-in appliance.
N/A
IE: equipment fitted with a flexible cable or cord provided with
a 13 A plug in accordance with Statutory Instrument 525:97
a 13 A plug in accordance with Statutory Instrument 525:97
Direct plug-in appliance.
N/A
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the following
amendments:
amendments:
N/A
- dimensions 2,5 A, 250 V socket-outlets shall comply with
Standard Sheet 1 page 132 of EN 60 065:98
Standard Sheet 1 page 132 of EN 60 065:98
No socket-outlets provided.
N/A
- mechanical strength 2,5 A, 250 V socket-outlets tested as
specified in EN 60 065, 12.1.3
specified in EN 60 065, 12.1.3
N/A
- protecting rim also tested
N/A
NO: method b) of 8.1 is not permitted. Double or reinforced
insulation is required between parts connected to the mains
and parts connected to the public telecommunications
network
insulation is required between parts connected to the mains
and parts connected to the public telecommunications
network
N/A