JBL ON TIME 200ID EMC - CB Certificate ▷ View online
<12014165 001>
Page 48 of 73
National Deviation
Clause
Requirement – Test
Result - Remark
Verdict
Canadian National Difference according to CB Bulletin No. 109A, December 2005
17.9A.1
Adhesive securement
The following parts, the displacement of which may result in a
fire or shock hazard, shall not be secured solely by adhesive,
unless the adhesive system complies with the resistance to
external forces test fo Clause 9.1.7, the bump test of Clasue
12.1.1, and the impact test of Clause 12.1.3, after
conditioning in accordance with Clause 17.9A.2:
fire or shock hazard, shall not be secured solely by adhesive,
unless the adhesive system complies with the resistance to
external forces test fo Clause 9.1.7, the bump test of Clasue
12.1.1, and the impact test of Clause 12.1.3, after
conditioning in accordance with Clause 17.9A.2:
a) internal metal parts/conductive coatings;
b) barriers; and
c) required enclosure parts.
Note: Cathode ray tubes are excluded from this test.
N/A
17.9A.2
Adhesive and conductive coating securement conditioning
N/A
17.9A.2.1 General
Where required by Clause 17.9A.1, one sample of the
apparatus or enclosure section shall be conditioned in
accordance with the requirements of Clause 17.9A.2.2.
Equivalent ageing test data supplied by the manufacturer will
be considered in lieu of ageing.
apparatus or enclosure section shall be conditioned in
accordance with the requirements of Clause 17.9A.2.2.
Equivalent ageing test data supplied by the manufacturer will
be considered in lieu of ageing.
N/A
<12014165 001>
Page 49 of 73
National Deviation
Clause
Requirement – Test
Result - Remark
Verdict
Canadian National Difference according to CB Bulletin No. 109A, December 2005
17.9A.2.2 Ageing
Day 1: Place in oven at 100
±
1°C for 1 week, or 82
±
1°C for 8
weeks at the manufacturer’s option.
Day 8 or Day 57:
1. Remove from oven and leave at room temperature for
1h.
2. Place in freezer at –35°C for 2h.
3. Remove from freezer and allow to reach room
temperature overnight.
Day 9 or Day 58:
1. Place in a compartment at 96% relative humidity for 3h.
2. Remove and leave at room temperature and humidity for
1h.
3. Place in oven at a temperature selected in the first cycle
for 3h.
4. Remove and allow to come to room temperature
overnight.
Day 10 or Day 59:
1. Place in Freezer at –35°C for 2h.
2. Remove and leave at room temperature for 1h.
3. Place in humidity chamber at 96% relative humidity for
3h.
4. Remove and allow to come to room temperature
overnight.
Day 11 or Day 60:
1. Place in oven at a temperature selected in the first cycle
for 3h.
2. Remove for 1h.
3. Place in Freezer at –35°C for 2h.
4. Remove and allow to come to room temperature
overnight.
Day 12 or Day 61:
1. Place in humidity chamber at 96% relative humidity for
3h.
N/A
<12014165 001>
Page 50 of 73
National Deviation
Clause
Requirement – Test
Result - Remark
Verdict
Canadian National Difference according to CB Bulletin No. 109A, December 2005
2. Remove and perform mechanical tests as required by
Clause 17.10.1 or 17.10.2 as applicable.
18
Mechanical strength of picture tubes and protection against
the effects of implosion
the effects of implosion
No picture tubes provided.
N/A
18.1A
Add the following clause
A picture tube with a maximum face dimension exceeding
75mm either shall be intrinsically protected with respect to
effects of implosion and to mechanical impact in accordance
with CAN/CSA - C22.2 No. 228 or CAN/CSA – E61965, or the
enclosure of the apparatus shall provide adequate protection
against the effects of an implosion of the tube (see Clause
12)
75mm either shall be intrinsically protected with respect to
effects of implosion and to mechanical impact in accordance
with CAN/CSA - C22.2 No. 228 or CAN/CSA – E61965, or the
enclosure of the apparatus shall provide adequate protection
against the effects of an implosion of the tube (see Clause
12)
N/A
19
Stability and mechanical hazards
Add the following after the second paragraph
The test of Clause 19.3 is only required for
a) apparatus with a mass of 25kg or more
b) apparatus, excluding loudspeaker systems, with a height
of 1m or more, or
c) apparatus, including loudspeaker systems, in
combination with a supplied or recommended cart of
stand with a total height of 1m or more.
stand with a total height of 1m or more.
Add the following paragraph
Apparatus not tested because it is intended to be fastened in
place shall be provided with the following warning:
place shall be provided with the following warning:
“WARNING: This apparatus must be securely attached to the
floor/wall per installation instruction. Tipping, shaking or
rocking the machine may cause injury/death.”
floor/wall per installation instruction. Tipping, shaking or
rocking the machine may cause injury/death.”
Not such equipment
N/A
20.2
20.2.1A
Fire enclosure
Add the following clause
Enclosures of apparatus containing high voltage or
projection lamps shall have a minimum flammability rating
of category FV1 according to IEC 60707 at the minimum
thickness used.
projection lamps shall have a minimum flammability rating
of category FV1 according to IEC 60707 at the minimum
thickness used.
No such component
N/A
<12014165 001>
Page 51 of 73
National Deviation
Clause
Requirement – Test
Result - Remark
Verdict
Canadian National Difference according to CB Bulletin No. 109A, December 2005
Annex B
(normative)
Apparatus to be connected to the telecommunication
networks
networks
Replace this annex with the following
Apparatus intended for direct connection to a
telecommunication network shall comply with
telecommunication network shall comply with
a) Clasue 19 of CSA C22.2 No.1; or
b) CAN/CSA – C22.2 No. 60950.
No TNV
N/A
Click on the first or last page to see other ON TIME 200ID service manuals if exist.