Page 48 of 73 
 
National Deviation 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Canadian National Difference according to CB Bulletin No. 109A, December 2005 
 
17.9A.1 
Adhesive securement 
The following parts, the displacement of which may result in a 
fire or shock hazard, shall not be secured solely by adhesive, 
unless the adhesive system complies with the resistance to 
external forces test fo Clause 9.1.7, the bump test of Clasue 
12.1.1, and the impact test of Clause 12.1.3, after 
conditioning in accordance with Clause 17.9A.2: 
a) internal metal parts/conductive coatings; 
b) barriers; and 
c) required enclosure parts. 
Note: Cathode ray tubes are excluded from this test. 
 
N/A 
17.9A.2 
Adhesive and conductive coating securement conditioning 
 
N/A 
17.9A.2.1  General 
Where required by Clause 17.9A.1, one sample of the 
apparatus or enclosure section shall be conditioned in 
accordance with the requirements of Clause 17.9A.2.2. 
Equivalent ageing test data supplied by the manufacturer will 
be considered in lieu of ageing. 
 
N/A 
 
 
<12014165 001> 
 
 
Page 49 of 73 
 
National Deviation 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Canadian National Difference according to CB Bulletin No. 109A, December 2005 
 
17.9A.2.2  Ageing 
Day 1: Place in oven at 100
±
1°C for 1 week, or 82
±
1°C for 8 
weeks at the manufacturer’s option. 
Day 8 or Day 57: 
1.  Remove from oven and leave at room temperature for 
1h. 
2.  Place in freezer at –35°C for 2h. 
3.  Remove from freezer and allow to reach room 
temperature overnight. 
Day 9 or Day 58: 
1.  Place in a compartment at 96% relative humidity for 3h. 
2.  Remove and leave at room temperature and humidity for 
1h. 
3.  Place in oven at a temperature selected in the first cycle 
for 3h. 
4.  Remove and allow to come to room temperature 
overnight. 
Day 10 or Day 59: 
1.  Place in Freezer at –35°C for 2h. 
2.  Remove and leave at room temperature for 1h. 
3.  Place in humidity chamber at 96% relative humidity for 
3h. 
4.  Remove and allow to come to room temperature 
overnight. 
Day 11 or Day 60: 
1.  Place in oven at a temperature selected in the first cycle 
for 3h. 
2.  Remove for 1h. 
3.  Place in Freezer at –35°C for 2h. 
4.  Remove and allow to come to room temperature 
overnight. 
Day 12 or Day 61: 
1.  Place in humidity chamber at 96% relative humidity for 
3h. 
 
N/A 
 
 
<12014165 001> 
 
 
Page 50 of 73 
 
National Deviation 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Canadian National Difference according to CB Bulletin No. 109A, December 2005 
 
 
2.  Remove and perform mechanical tests as required by 
Clause 17.10.1 or 17.10.2 as applicable. 
 
 
18 
Mechanical strength of picture tubes and protection against 
the effects of implosion 
No picture tubes provided. 
N/A 
18.1A 
Add the following clause 
A picture tube with a maximum face dimension exceeding 
75mm either shall be intrinsically protected with respect to 
effects of implosion and to mechanical impact in accordance 
with CAN/CSA - C22.2 No. 228 or CAN/CSA – E61965, or the 
enclosure of the apparatus shall provide adequate protection 
against the effects of an implosion of the tube (see Clause 
12) 
 
N/A 
19 
Stability and mechanical hazards 
Add the following after the second paragraph
 
The test of Clause 19.3 is only required for 
a)  apparatus with a mass of 25kg or more 
b)  apparatus, excluding loudspeaker systems, with a height 
of 1m or more, or 
c)  apparatus, including loudspeaker systems, in 
combination with a supplied or recommended cart of 
stand with a total height of 1m or more. 
Add the following paragraph 
Apparatus not tested because it is intended to be fastened in 
place shall be provided with the following warning: 
“WARNING: This apparatus must be securely attached to the 
floor/wall per installation instruction. Tipping, shaking or 
rocking the machine may cause injury/death.” 
Not such equipment 
N/A 
20.2 
20.2.1A 
Fire enclosure 
Add the following clause 
Enclosures of apparatus containing high voltage or 
projection lamps shall have a minimum flammability rating 
of category FV1 according to IEC 60707 at the minimum 
thickness used. 
No such component 
N/A 
 
 
<12014165 001> 
 
 
Page 51 of 73 
 
National Deviation 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
Canadian National Difference according to CB Bulletin No. 109A, December 2005 
 
Annex B 
(normative) 
Apparatus to be connected to the telecommunication 
networks 
Replace this annex with the following 
Apparatus intended for direct connection to a 
telecommunication network shall comply with 
a)  Clasue 19 of CSA C22.2 No.1; or 
b)  CAN/CSA – C22.2 No. 60950. 
No TNV 
N/A 