JBL ON TIME 200ID EMC - CB Certificate ▷ View online
<12014165 001>
Page 32 of 73
IEC60065E
ASTABEAB
10
T1 secondary
winding (N2)
winding (N2)
SC
--
AC current: 0,03A→0,19A, unit protection, 5 min, no
hazards.
hazards.
11
IC1 (pin 1-5)
SC
--
AC current: 0,03A, unit protection, 5 min, no
hazards.
hazards.
12
R15
SC
--
F1 opened immediately. The test was repeated 3
times on models used fusing resistor, no hazards.
times on models used fusing resistor, no hazards.
13
R15
OC
--
AC current: 0,03A→0,09A, unit protection, 5 min, no
hazards.
hazards.
14
IC2 pins in primary
circuit
circuit
SC
--
AC current: 0,03A unit protection, 5 min, no
hazards.
hazards.
15
IC2 pin in primary
circuit
circuit
OC
--
AC current: 0,03A→0,16A, unit protection, 5 min, no
hazards.
hazards.
16
IC2 pins in
secondary circuit
secondary circuit
SC
--
AC current: 0,03A→0,13A, unit protection, 5 min, no
hazards.
hazards.
17
IC2 pin in
secondary circuit
secondary circuit
OC
--
AC current: 0,03A→0,16A, unit protection, 5 min, no
hazards.
hazards.
18
D3
SC
--
AC current: 0,03A→0,22A, unit protection, 5 min, no
hazards.
hazards.
19
T1 secondary
winding
winding
OL
--
Overload to 1,47A, 5,6 hrs, no hazards.
T1 winding=80,6K, limit: 120K
L1 winding=59,8K, limit: 85K
PCB under D3=65,5K, limit: 85K
Optocoupler=50,1K, limit: 55K
Output cord=27,0K, limit: 90K
Enclosure=41,5K, limit: 55K
T1 winding=80,6K, limit: 120K
L1 winding=59,8K, limit: 85K
PCB under D3=65,5K, limit: 85K
Optocoupler=50,1K, limit: 55K
Output cord=27,0K, limit: 90K
Enclosure=41,5K, limit: 55K
20
Output
SC
--
AC current: 0,03A→0,06A, unit protection, 5 min, no
hazards.
hazards.
21
Output
OL
--
Overland to 1,45A, 5,6 hrs, no hazards.
T1 winding=84,0K, limit: 120K
L1 winding=61,1K, limit: 85K
PCB under D3=71,7K, limit: 85K
Optocoupler=51,2K, limit: 55K
Output cord=30,0K, limit: 90K
Enclosure=43,2K, limit: 55K
T1 winding=84,0K, limit: 120K
L1 winding=61,1K, limit: 85K
PCB under D3=71,7K, limit: 85K
Optocoupler=51,2K, limit: 55K
Output cord=30,0K, limit: 90K
Enclosure=43,2K, limit: 55K
Model S024EV1200200
22
T1 secondary
winding
winding
OL
--
Overload to 2,5A, 5,6 hrs, no hazards.
T1 winding=69,4K, limit: 120K
L1 winding=55,6K, limit: 85K
PCB under D3=61,5K, limit: 85K
Optocoupler=42,8K, limit: 55K
Output cord=18,5K, limit: 90K
Enclosure=40,1K, limit: 55K
T1 winding=69,4K, limit: 120K
L1 winding=55,6K, limit: 85K
PCB under D3=61,5K, limit: 85K
Optocoupler=42,8K, limit: 55K
Output cord=18,5K, limit: 90K
Enclosure=40,1K, limit: 55K
<12014165 001>
Page 33 of 73
IEC60065E
ASTABEAB
23
Output
SC
--
AC current: 0,03A→0,07A, unit protection, 5 min, no
hazards.
hazards.
24
Output
OL
--
Overload to 2,5A, 5,6 hrs, no hazards.
T1 winding=72,9K, limit: 120K
L1 winding=57,0K, limit: 85K
PCB under D3=66,5K, limit: 85K
Optocoupler=46,4K, limit: 55K
Output cord=24,2K, limit: 90K
Enclosure=44,4K, limit: 55K
T1 winding=72,9K, limit: 120K
L1 winding=57,0K, limit: 85K
PCB under D3=66,5K, limit: 85K
Optocoupler=46,4K, limit: 55K
Output cord=24,2K, limit: 90K
Enclosure=44,4K, limit: 55K
Model S024EV0600300
25
T1 secondary
winding
winding
OL
--
Overload to 4,0A, 5 hrs, no hazards.
T1 winding=72,3K, limit: 120K
L1 winding=56,3K, limit: 85K
PCB under D3=68,8K, limit: 85K
Optocoupler=46,6K, limit: 55K
Output cord=30,7K, limit: 90K
Enclosure=41,1K, limit: 55K
T1 winding=72,3K, limit: 120K
L1 winding=56,3K, limit: 85K
PCB under D3=68,8K, limit: 85K
Optocoupler=46,6K, limit: 55K
Output cord=30,7K, limit: 90K
Enclosure=41,1K, limit: 55K
26
Output
SC
--
AC current: 0,03A→0,06A, unit protection, 5 min, no
hazards.
hazards.
27
Output
OL
--
Overload to 3,95A, 6 hrs, no hazards.
T1 winding=76,6K, limit: 120K
L1 winding=59,0K, limit: 85K
PCB under D3=75,6K, limit: 85K
Optocoupler=51,8K, limit:55K
Output cord=36,1K, limit: 90K
Enclosure=44,5K, limit: 55K
T1 winding=76,6K, limit: 120K
L1 winding=59,0K, limit: 85K
PCB under D3=75,6K, limit: 85K
Optocoupler=51,8K, limit:55K
Output cord=36,1K, limit: 90K
Enclosure=44,5K, limit: 55K
Model S024EV0300300
28
T1 secondary
winding
winding
OL
--
Overload to 3,7A, 5 hrs, no hazards.
T1 winding=43,7K, limit: 120K
L1 winding=38,2K, limit: 85K
PCB under D3=44,8K, limit: 85K
Optocoupler=30,6K, limit: 55K
Output cord=21,1K, limit: 90K
Enclosure=27,6K, limit: 55K
T1 winding=43,7K, limit: 120K
L1 winding=38,2K, limit: 85K
PCB under D3=44,8K, limit: 85K
Optocoupler=30,6K, limit: 55K
Output cord=21,1K, limit: 90K
Enclosure=27,6K, limit: 55K
29
Output
SC
--
AC current: 0,03A→0,06A, unit protection, 5 min, no
hazards.
hazards.
30
Output
OL
--
Overload to 3,7A, 6 hrs, no hazards.
T1 winding=47,2K, limit: 120K
L1 winding=40,4K, limit: 85K
PCB under D3=48,9K, limit: 85K
Optocoupler=34,7K, limit: 55K
Output cord=25,7K, limit: 90K
Enclosure=30,2K, limit: 55K
T1 winding=47,2K, limit: 120K
L1 winding=40,4K, limit: 85K
PCB under D3=48,9K, limit: 85K
Optocoupler=34,7K, limit: 55K
Output cord=25,7K, limit: 90K
Enclosure=30,2K, limit: 55K
Winding temperature rise measurements
Ambient temperature t1 (
o
C) ................................
—
<12014165 001>
Page 34 of 73
IEC60065E
ASTABEAB
Ambient temperature t2 (
o
C) ................................
—
Note(s): SC=Short-circuited, OL=Overload, OC=Open-circuited.
13
TABLES: clearances and creepage distances
P
Rated supply voltage:
220-240V
Pollution degree:
2
Material Group:
IIIa or IIIb
2 N force on internal parts applied:
Yes
30 N force on outside of conductive enclosure applied:
Yes
Location
Operating Voltage
Clearance (mm)
Creepage (mm)
V rms
V peak
Min
Actual
Min
Actual
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below.
Unit:
primary components (with 10N) →
secondary components (with 10N)
272
496
4.4
6.9
5.8
6.9
Unit:
primary components (with 10N) →
secondary component core T1 (with 10N)
272
496
4.4
6.9
5.8
6.9
PCB: primary → secondary traces
under IC2
under IC2
250
420
4.0
6.1
5.0
6.1
PCB: primary → secondary traces
under T1
under T1
272
496
4.4
7.2
5.8
7.2
PCB: primary → secondary traces
under CY1
under CY1
250
420
4.0
7.2
5.0
7.2
Unit:
primary components
→ accessible part (outside enclosure)
250
420
4.0
5.1
5.0
5.1
PCB: trace between two poles of F1
250
420
1.5
3.1
2.5
3.1
PCB: trace between different polarity
before F1
before F1
250
420
1.5
4.4
2.5
4.4
Notes:
1. Core of T1 is considered as primary circuit.
2. Glued components: BR1, L1, L2, IC3, IC2, CY1, L3, L1.
3. 2 layers Insulation tape wrapped T1, secondary heat sink and primary heat sink surface.
4. T1 construction: concentric winding on EF25 phenolic bobbin. 2 layers of insulation tape between primary
(enameled copper wire) and secondary winding (triple insulation wire), 2 layers on outer winding. Outer winding is
primary. Teflon tube is provided on primary winding and secondary winding exit. 2 layers of insulation tape were
wrapped on the iron core. 2 layers of insulation tape were wrapped on outside of transformer.
"Min" = minimum required.
"Actual = Actual dimensions measured.
<12014165 001>
Page 35 of 73
IEC60065E
ASTABEAB
14
TABLE: list of critical components and materials
P
Object/Part No.
Manufacturer
/Trademark
/Trademark
Type/Model
Technical Data
2
)
Standard
Mark(s) of
Conformity
Conformity
1
)
Transformer (T1) Huizhou Sky
Fortune
(1) T10210
(2) T10211
(3) T10249
(4) T10212
(5) T10213
(2) T10211
(3) T10249
(4) T10212
(5) T10213
Pri. Winding (pin 4-5):
Ø0,37mm×74Ts
Auxiliary Pri. Winding
(pin 1-2):
Ø0,15mm×22Ts
Sec. Winding (pin A-B):
(1) Ø0,55mm×3P×6Ts
(2) Ø0,55mm×2P×9Ts
(3) Ø0,80mmx13Ts
(4) Ø0,60mm×17Ts
(5)
Ø0,35mm×2Px26Ts
Class B
Ø0,37mm×74Ts
Auxiliary Pri. Winding
(pin 1-2):
Ø0,15mm×22Ts
Sec. Winding (pin A-B):
(1) Ø0,55mm×3P×6Ts
(2) Ø0,55mm×2P×9Ts
(3) Ø0,80mmx13Ts
(4) Ø0,60mm×17Ts
(5)
Ø0,35mm×2Px26Ts
Class B
Applicable part
of IEC 60065
and according to
IEC 60085
of IEC 60065
and according to
IEC 60085
Accepted by
TÜV Rheinland
TÜV Rheinland
-Triple insulated
wire
wire
Kuo Kuang
REFU-B
Class B
IEC/EN 60950
VDE
UL E222087
UL E222087
(Alternative)
Totoku
TIW-2, TIW-3
Class B
IEC/EN 60950
VDE
UL E166483
UL E166483
(Alternative)
Furukawa
TEX-B
Class B
IEC/EN 60950
VDE
UL E206440
UL E206440
- Magnet wire
Ronsen
UEW/130
130°C
--
UL E164502
(Alternative)
Huiyang Golden
Ocean
Ocean
XUEW#
130°C
--
UL E225143
(Alternative)
Xingning Jinyan
UEW
130°C
--
UL E238500
-Tubing
Great Holding
TFS
Min.600V, 200°C,
VW-1
VW-1
--
UL E156256
(Alternative)
Changyuan
CB-TT
Min.600V, 200°C,
VW-1
VW-1
--
UL E180908
-Insulation tape
Jingjiang Yahua
CT, PZ, WF
130°C
--
UL E165111
(Alternative)
Duck Sung
DTS-204
130°C
--
UL E105147
(Alternative)
P Leo
1P801, 1P802+ 130°C
--
UL E126174
-Bobbin
Chang Chun
T375J
PF, V-0, 150°C, min.
Thickness: 0,5mm
Thickness: 0,5mm
--
UL E59481
(Alternative)
Sumitomo
Bakelite
Bakelite
PM-9820, PM-
9630
9630
PF, V-0, 150°C, min.
Thickness: 0,5mm
Thickness: 0,5mm
--
UL E41429
(Alternative)
Hitachi
CP-J-8800
PF, V-0, 150°C, min.
Thickness: 0,5mm
Thickness: 0,5mm
--
UL E42956
Click on the first or last page to see other ON TIME 200ID service manuals if exist.